GE
Lighting Solutions
Tetra® LED Control Module
(GECLPS3-2)
LED Control Module Features
• LED Control Module for GECLPS3 and GECLPS4 retrot.
• UL: Class 2 input.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before
servicing or installing product.
• Properly ground Tetra® power supply.
RISK OF FIRE
• Use only Tetra® supply wire to make connection from
Tetra® power supply to Tetra® LED strip.
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82 mm2)
• Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
• N’utilisez que le l d’approvisionnement Tetra® pour faire la connexion entre
l’alimentation Tetra® et la bande DEL Tetra®.
• N’utilisez que des ls approuvés pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82 mm2).
• Respectez tous les codes locaux.
Installation Guide
24
Volt
RISK OF INJURY
• While performing installations described, gloves, safety glasses
or goggles should be worn.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• Limited to use in dry and damp locations.
• The grounding and bonding of the LED Driver shall be done in
accordance with National Electric Code (NEC) Article 600.
• Follow all National Electric Codes (NEC) and local codes.
• These products are only suitable for connection to a circuit
from a Class 2 power source. These products have not been
evaluated for use when connected to a power source that does
not comply with Class 2 voltage and energy limited supplies.
imagination at work
CAUTION/ATTENTION
RISQUE DE BLESSURE
• Lors de l’exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must
accept any interference received, including interference that
may cause undesired operation.
Note: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
This Class [A] RFLD complies with the Canadian standard
ICES-003. Ce DEFR de la classe [A] est conforme à la NMB-003
du Canada.

Components
UL certied 22-14 AWG (0.33-2.08 mm2) wire connectors or
1
1 2 3
22-18 AWG (0.33-0.82 mm2) .
Tetra® 24 Volt Power Supply.
2
Tetra® LED Control Module.
3
Remove Existing Lighting Equipment
Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure that the
branch circuit supplying the existing LED power supply will be within the voltage ratings of the new LED power supply, and have a
current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).
If removal of the existing lighting equipment (see Step 2 in this section) eliminates the disconnect switch, as required by applicable local,
state, or country electrical codes; a new disconnect switch must be installed. If required, the disconnect switch shall be installed by
qualied personnel, in accordance with applicable local, state, and country electrical codes.
Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in all holes
0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an
aluminum or zinc coated steel patch with rivets and sealant.
Turn off power and remove panel from the channel
1
letter.
Electrical Connections
GECLPS3
=
GECLPS3-2GEPS24-100-XX
One GECLPS3-2 and one 24VDC, 100W, Class 2 Tetra
3 4
LED Driver will be required to replace each GECLPS3 or
up to four GECLPS4 LED drivers.
NOTE: Mount the LED driver and LED control module
within the sign or other enclosure.
Remove the existing GECLPS3. Do not remove existing
2
channel letters and wiring.
NOTE: Follow all federal and local regulations when
disposing of existing LED drivers.
LED driver LED driver
4”
LED driver
If installing multiple LED control modules or LED drivers in
the same compartment, keep them at least 2” (50.8mm)
apart end to end and 4” (101.6mm) apart along the sides.
NOTE: All drivers except GEPS24-180U must be installed
in a enclosure or be provided with a GEPSJB60 LED driver
extended enclosure.
LED driver
2”