Read these instructions completely and carefully.
Save these instructions for future use.
Risk of electrical shock. Disconnect power before servicing
or installing product.
LED Area Light
WARNING
Installation Guide
GEH-6014A
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
WARNING
Risk of re. Use supply wire specied on nameplate.
CAUTION
Risk of injury. Wear safety glasses and gloves during
installation and servicing.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This Class [A] RFLD complies with the Canadian standard ICES-003.
Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
• This luminaire is designed for outdoor lighting
applications, and should not be used in areas of
limited ventilation, or in high ambient temperature
enclosures.
• Best results will be obtained if installed and
maintained according to the recommendations that
follow.
• This luminaire is designed to operate in ambient
temperatures ranging from -40°C to 50°C and to be
mounted horizontally on a vertical wall with LEDs
facing down.
SPECIFICATIONS
• Weight: 21 lbs. (9.5kg)
• Optical and all Electrical Components IP65; Mounting
box UL 1598 Wet Location Rated
imagination at work
UNPACKING
1
MOUNTING
4
• This luminaire has been properly packed so that
no parts should have been damaged during transit.
• Inspect to conrm.
HANDLING
2
• Damage may occur if luminaire is improperly
handled outside of pack.
• Do not impact or stack luminaire after removal
from packaging.
OUTLET BOX MOUNTING
3
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
• The luminaire can be mounted to a suitable recessed
mounted outlet box (3 1/2-in. or 4-in. octagonal).
• The Mounting Box may be attached to the outlet box
with two 10-24 screws (not provided), approximately
1” (25mm) long.
• Remove the back Mounting Box by loosening the
single screw on the front of the unit and sliding the
Mounting Box downward o of the mounting hook
(see Figure 2).
Mounting Box Screw
FIGURE 2
• Temporarily disconnect ground lead on xture from
tab on Mounting Box while installing mounting box.
• Attach the Mounting Box to the wall or outlet using
the holes in the cover as a drill template. Alternately,
the mounting diagram in these instructions may be
used as a drill template (see Figure 3).
• Connect electrical wires to the xture by pulling
wires from outlet box into mounting box. Hang unit
by tether for ease while wiring. Reconnect ground
from xture to tab on mounting box then connect
wire on unit to wires from outlet box.
• An alternate method of mounting the Mounting Box
over a recessed-mounted outlet box is to position
back cover over the box and securely mount with lag
bolts (not provided) through the holes provided in the
back cover (see Figure 1).
FIGURE 1
IMPORTANT: Connect ground lead to terminal
provided.
• Slide xture hook into the Mounting Box and secure
with single screw on front of unit.
MAINTENANCE / CLEANING
5
WARNING
Risk of electric shock. Make certain power is o before
attempting any maintenance.
• To maintain high eciency of the lens, occasional
cleaning of the outer lens surface may be needed,
with frequency dependant on local conditions.
• Use a mild soap or detergent, which is essentially
neutral pH (pH approximately 6 to 8), non abrasive,
and which contains no chlorinated or aromatic
hydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
STORAGE
6
• Prior to installation, units should NOT be stored
outside in corrugated boxes (cardboard boxes) alone.
• Until installation, all units should be placed in a
covered dry storage area. The storage area should
not exceed -40°C (-40°F) to 50°C (122°F).
- This can be preferably in a roofed area or with a
tarp that is secured in such a way to keep water
o of the corrugated boxes (cardboard boxes).
MOUNTING DIAGRAM
FIGURE 3
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in
connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not
covered suciently for the purchaser’s purposes, the matter should be referred to GE Lighting.
Lisez complètement et attentivement ces
instructions. Conservez ces instructions pour une
utilisation future.
AVERTISSEMENT
Risque de choc électrique. Déconnectez l’alimentation
électrique avant d’installer ou réparer ce produit.
AVERTISSEMENT
Danger de blessure ou de dommage matériel. L’appareil
tombera au sol s’il est mal installé. Suivez les instructions
d’installation.
AVERTISSEMENT
Danger de blessure ou de dommage matériel. L’appareil
tombera au sol s’il est mal installé. Suivez les instructions
d’installation.
ATTENTION
Risque de blessure. Lors de l’installation et de la réparation ce
cet appareil, portez des lunettes et des gants de sécurité.
Cet appareil est conforme aux exigences de la partie 15 des règles de la FCC.
Son utilisation est sujette aux conditions suivantes : (1) cet appareil ne doit
pas causer d’interférences nuisibles; (2) cet appareil doit accepter toutes les
interférences reçues, y compris celles pouvant causer un fonctionnement
indésirable. Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada.
Remarque : Cet appareil a été testé et reconnu conforme aux limites établies
pour les appareils numériques de classe A, selon la partie 15 des règles de la
FCC. Ces limites sont conçues pour assurer une protection raisonnable contre
les interférences nuisibles dans un environnement commercial. Cet appareil
génère, utilise et émet de l’énergie sous forme de radiofréquences, de sorte
que si son installation et son utilisation ne sont pas conformes à la notice
d’utilisation, il peut être la cause de parasites nuisibles aux communications
radio. L’utilisation de cet équipement dans une zone résidentielle risque fort
de causer des interférences nuisibles, auquel cas l’utilisateur devra corriger le
problème à ses propres frais.
• Ce luminaire est conçu pour des applications
d’éclairage extérieur, et ne doit pas être utilisé dans
des zones à ventilation limitée, ou des enceintes à
température élevée.
• Les meilleurs résultats seront obtenus s’il est installé
et entretenu selon les recommandations qui suivent.
• Ce luminaire est conçu pour fonctionner dans des
températures ambiantes allant de -40 à +50 °C, et
doit être monté horizontalement sur un mur vertical
avec ses diodes électroluminescentes (DEL) orientées
vers le bas.
SPÉCIFICATIONS
• Poids : 21 lbs. (9,5 kg)
• Optique et tous les composants électriques :
protection IP65 ; Boîtier de montage évalué UL 1598