GE Evolve EFM1 Installation Manual

Evolve
LED Flood Light
(EFM1)
BEFORE YOU BEGIN
Read these instructions completely and carefully. Save these instructions for future use.
WARNING
Risk of electrical shock. Disconnect power before servicing
Installation Guide
GEH-6066
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
WARNING
Risk of fire. Use supply wire specified on nameplate.
CAUTION
Risk of injury. Wear safety glasses and gloves during
installation and servicing.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] Lighting Equipment complies with Canadian standards ICES-005[A]/NMB-005[A].
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
GENERAL
• This luminaire is designed for outdoor lighting
applications, and should not be used indoors.
• Best results will be obtained if installed and
maintained according to this simplified guide.
• This ood light is provided with trunnion, pipe, or wall
mountings.
SPECIFICATIONS
Weight: 25 lbs. (11.34 kg)
Effective Projected Area (EPA):
- 90° aim (vertical glass) 1.96 sq. ft.
- 45° aim 1.22 sq. ft.
- Side profile (all aims) 0.73 sq. ft.
- 0° (face down) aim 0.79 sq. ft.
• Ingress Protection (IP) rating:
- Optical: IP66
- Electrical Enclosure: UL Wet Location
• Ambient temperature: -40°C (-40°F) to 50°C (140°F)
UNPACKING/HANDLING
1
Inspect luminaire to confirm no damage has occurred during transit.
• To avoid damage, do not impact or stack luminaire
after removal from packaging.
MOUNTING
2
2a. Pipe Mount: Mount on vertical 1-7/8 to 2-3/8-inch
O.D. or 2-3/8 to 3-inch O.D. pipes.
• Pipe must point upward such that gravity acts to hold
luminaire on pipe end.
• Do not mount unit upside down.
Tighten set screws to 25-30 ft-lbs (34-41 N-m) of torque.
Tighten Knuckle Bolt to 15 to 20 ft-lbs torque after aiming.
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Do NOT exceed 30 ft-lbs of torque on set screws or 20 ft-lbs of torque on knuckle bolt.
2b. Wall Mount: Mount to vertical surface using four
0.43-inch clearance holes spaced 4.37(H) x 2.87(V) inches with customer supplied fasteners/anchors.
• Seal wall mount ange to the mounting surface
with silicone caulk or equivalent.
Tighten Knuckle Bolt to 15 to 20 ft-lbs torque after aiming.
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Do NOT exceed 20 ft-lbs of torque on knuckle bolt.
FIGURE 1. Pipe Mount
2.875 in.
4 Holes
.430 in.
FIGURE 2. Wall Mount
Knuckle Bolt
Wiring Cover
Set Screws
Top Closure Screw
Door Hinge
Wiring Cover
Knuckle Bolt
4.375 in.
2c. Trunnion Mount: Mount on a at surface using a
customer supplied 3/4-inch bolt through the clearnace hole provided in the trunion bottom.
• Tighten two (2) side Trunion Bolts to 15 to 20 ft-lbs
torque after aiming.
• If desired, trunion can be secured against rotation
by using customer supplied fastner(s) through additional clearance holes in the trunion bottom.
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Do NOT exceed 20 ft-lbs of torque on trunnion bolt.
Trunnion Bolt
Clearance hole for Customer
Supplied 3/4” Bolt
FIGURE 3. Trunnion Mount
WIRING
3
Note: Make all electrical connections in accordance with National Electrical Code and any applicable local code requirements. Note: Verify supply voltage matches nameplate rating before wiring.
Verify service leads meet nameplate temperature rating.
• Units are provided with cable or leads exiting the
fixture for connection with service leads.
• For Pipe and Wall Mount open wire cover and connect
service lead to luminaire leads. Reclose wire cover.
• For Trunnion Mount connect service lead to luminaire
cable wiring.
• If cable or leads are removed and customer connects
service leads directly to the terminal board, see Table 1 for screw torque requirements.
60° MAX
FIGURE 5. Maximum Aiming Range with PE
PE Units: Regardless of mounting type, units with a
photoelectric receptacle cannot be aimed more than 60° degrees above horizontal.
Table 1. Terminal Board Screw Torque (UL Units):
Wire Range Copper Aluminum Torque (in lbs.)
10-16 SOL, STR 30 8-6 SOL, STR STR6, SOL, STR 45
Wired Dimming:
• Connect wired dimming control leads per Table 2.
Table 2. Wired Dimming Control Connections
0 VDC (-) Gray Lead Up to 10 VDC (+) Violet Lead
Front of sight
AIMING
4
FIGURE 4. Aiming Sight
Target
Rear of sight
MAINTENANCE / CLEANING
5
WARNING
Risk of electric shock. Make certain power is off before
attempting any maintenance.
Occasional cleaning of the outer lens surface may be needed.
• Use a mild non-abrasive soap or detergent,of
neutral pH (pH approximately 6 to 8), which contains no chlorinated or aromatic hydrocarbons.
Wash thoroughly, using a soft cloth.
Rinse with clean, cold water and wipe dry.
STORAGE
6
Packaged units should NOT be stored unprotected outdoors in corrugated (cardboard) boxes.
• Store packaged units in a covered dry area not exceeding -40 °C (-40 °F) to 50 °C (122 °F) such as a roofed area or covered with a secured tarp to keep water off the corrugated (cardboard) packaging.
An “aiming-sight” for point aiming is provided on the top of the luminaire.
• Tilt or Rotate luminaire to align the front and rear
sights so that equal space shows on either side and the desired target point is centered in the groove.
• Tighten trunnion or knuckle bolts per instructions in
Section 2.
CONTROLS
7
If using a PE socket-based control, refer to instructions included with control regarding appropriate settings for dimming and other control features.
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to Current, powered by GE.
All trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current, powered by GE is a business of the General Electric Company. © 2018 GE.
www.currentbyge.com GEH6066 (Rev 01/11/18)
99004035
Loading...
+ 8 hidden pages