DCCD330GG
DCCB330 QS
6/16/03 km
36
27
25-1/2
42
GE® Super 7.0 Cu. Ft. Capacity Coin-Operated Gas Dryer
Dimensions and Installation Information (in inches)
Exhaust Options:
Shipped with exhaust to the rear.
When viewed from the front of the unit , exhaust 3-way via left , bottom and rear. Maximum
recommended exhaust duct length is 15 feet of 4" rigid ducting with two 90° elbows and dampered
wall cap.
(See Installation Instructions)
Gas – An individual branch circuit fused for 15- or 20-amp is required for each dryer.
Gas Dryer Rating:
120V, 60Hz
Gas (BTU/HR):
20,000. Factory equipped for natural gas. Tested for LP gas. A conversion kit is required for LP gas.
Check installation instructions for correct kit number. Have a qualified technician install the conversion
kit. Equipped with energy saving Glo-Bar ignition.
Dryer Note:
Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is
mounted in position.
Installation Information:
For complete installation information see installation instructions packed with product.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Specification Revised 5/09
370402
DCCD330GG
Best performance
Domestic
dryer models
Maximum length of 4"
dia. rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4"
opening
B
2-1/2"
opening
7.0, 6.0 and 5.8 cu. ft.
capacity models
all electric dryers
0
1
2
3
4
90 ft.
60 ft.
45 ft.
35 ft.
25 ft.
60 ft.
45 ft.
35 ft.
25 ft.
15 ft.
A
4
B
2-1/2
A
GE® Super 7.0 Cu. Ft. Capacity Coin-Operated Gas Dryer
Dimensions and Installation Information (in inches)
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all-rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid)
ducting can be used (Kit WX08X10077). In special installations, it may be necessary to
connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed
flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or
flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter can be
maintained throughout the entire length of the transition duct. Please see installation
instruction packed with your dryer for complete instructions when using flexible metal
(foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the
side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated
is shown in the table.
2. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be
treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust into
a common duct or plenum with a kitchen exhaust, since the combination of lint and
grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any
other obstruction with the opening pointed down.
For answers to your Monogram,
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
®
GE Profile™ or
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label
on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq.
in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must
contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors. See installation instructions.
• The installation must conform with the local codes, or in the absence of local codes, with the
National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" both sides
3" rear
Dryer Exhausting Information – Use Metal Duct Only
Vertical and Horizontal Ducting
Specification Revised 5/09