GE DCCB330EG1WC, DCCB330EG2WC, DCCB330EG3WC, DCCB330EG4WC, DCCB330EJ0WC Installation Guide

...
ElectricDryerl
__ 44 !
,m_
BEFOREYOU BEGIN
Read these instructions completely and carefully.
IMPORTANT -Save_ese
instructions for local inspector's use.
.IMPORTANT -Observeall
goveming codes and ordinances.
the customer.
Note to Customer - Keep these instructions with your Use and Care Book for future reference.
This dryer must be exhausted outdoors.
, Before the old dryer is removed from service or discarded,
remove the dryer door.
Service information and the wiring diagram are located in the control console.
- Do not allow children on or in the appliance. Close supervision of children is necessary when the appliance is
used near children.
TOOLS YOU
MATERIALS YOU WiLL NEED
FORYOUR SAFETY:
_[kWARNING
Use only rigid metal or flexible metal 4-in. diameter ductwork for exhausting to the outdoors. Never use plastic or other combustible, easy-to-puncture ductwork.
This appliance must be properly grounded and installed as described in these instructions.
Do not install or store appliance in an area where it will be exposed to water and/or weather
Install the dryer where the temperature is above 50°F for satisfactory operation of the dryer control system.
NOTE: instaUation and service of this dryer J requires basic mechanical and electrical skills. J it is your responsibiliW to contact a qualified installer to make the electrical ¢onnect!_o_n__S. J
WiLL NEED
SLiPJOINTPLIERS
FLATBLADESCREWDRIVER
PHiLLiPSSCREWDRIVER
%
Step 1
Step 2
Step 3 Step 4 Step 5 Step 6 Step 7
Prepare the Area and Exhaust for Installation of New Dryer (see section 1). Check and Ensure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation Specifications (see section 3). Remove the Foam Shipping Pads (see section 1). Move the Dryer to the Desired Location. Connect the Power Supply (see section 2).
Connect the External Exhaust (see section 4). Level Your Dryer (see section 5).
DiA.METALDUCT
(RECOMMENDED) 4"DUCT
CLAMPS(2) OR
4"SPRING CLAMPS(2)
4"DIA.FLEXIBLEMETALDUCT_
(IFNEEDED)
%
4"DIA.METAL
ELBOW
DUCTTAPE
EXHAUSTHOODSAFETYGLASSES
_ 3/4=_RELIEF
GLOVES ULRECOGNIZED
Step 8
Step 9
Check the Operation of the Power Supply and Venting. Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation, see section 6. For Bathroom or Bedroom Installation, see section 7.
For Mobile or Manufactured Home see, section 8.
For side or bottom exhaust, see section 9.
DRYERPOWER
CORDKIT
(NOTPROVIDED
WITHDRYER)
ULRATED120/240V,30A WITH3OR4PRONGS. iDENTIFYTHEPLUGTYPE
ASPERTHEHOUSE
RECEPTACLEBEFORE PURCHASINGLINECORD.
Installation instructions
Minimum Clearance Other Than Alcove or Closet Installation I
Minimum clearance to combustible sm'faces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration _or installation and service. !
[] PREPARING FOR INSTALLATION [] ELECTRICAL CONNECTION
OF NEW DRYER iNFORMATiON
WARNING - TO REDUCE THE RISK OF
EXTERNAL
DUCT
OPENING
OR
DUCTCLAMP
4"METALDUCT
DUCTTAPEOR DUCTCLAMP
TIP: Install your dryer before installing your washer. This will allow better access when installing dryer exhaust.
REMOVING LiNT FROM WALL EXHAUST OPENING
FIRE_ ELECTRICAL SHOCK AND PERSONAL
INJURY:
- DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE. Dryer must be electrically grounded in accordance with
local codes and ordinances, or in the absence of local codes, in accordance with the NATIONAL ELECTRI- CAL CODE, ANSI/NFPA NO. 70.
ELECTRICAL REQUIREMENTS
This dryer must be comlected to an individual branch circuit, protected by the required time-delay fuses or circuit breakers. A
four or three-wire, single phase, 120/240V or 120/208V, 60Hz, 30 amp circuit is required.
If the electric supply does not meet the above specifications, then call a licensed electrician.
GROUNDING iNSTRUCTiONS
This dryer must be connected to a grounded metal, permanent
wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-
grounding terminal on the appliance.
INTERNALDUCT
OPENING...._
WALL
CHECKTHATEXHAUST
tHOODDAMPEROPENS
ANDCLOSESFREELY.
TILTTHEDRYERSIDEWAYS ANDREMOVETHE FOAM SHIPPINGPADSBY PULLINGATTHESIDES ANDBREAKINGTHEM
AWAYFROMTHEDRYER LEGS,BESURETO REMOVEALLOFTHE FOAMPIECESAROUND THELEGS.
CONNECTING DRYER USING 4-WIRE CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: Since January 1,1996, the National Electric code requires
that the new constructions utilize a 4-wire connection to
an electric dryer
WARNUNG:Only a 4-conductor cord shall be used when the appliance is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through the neutral is prohibited for the new branch-circuit installations, mobile homes
recreational vehicles, and areas where local codes prohibit grounding through the neutral conduction.
REMOVEGROUNDSTRAP ANDDISCARD.KEEPGREEN
GROUNDSCREW WIRE RELOCATEGREEN
_'_-... GROUNDSCREW
J
HOT_"_,
HERE
GREENOR
3/4",UL
HOT RECOGNIZED
WIRE STRAINRELIEF
COVER CONDUCTORS OR120/240V 30A POWER
2 WiTHUPTURNEDENDS(NOTSUPPLIED}.
4#10AWGMINIMUMCOPPER SUPPLYCORDKITMARKEDFORUSE
WiTHDRYERS& PROVIDEDWITH
CLOSED LOOPOR SPADETERMINALS
Installation
instructions
1. Turn off the circuit breaker (s) (30 amp) or remove the dryer's circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall receptacle.
3. Remove the power cord cover located at the lower back.
4. Remove and discard ground strap. Keep the green ground screw for step 7.
5. Install 3/4 in. UL recognized strain relief to power cord entry hole. Bring power cord through strain relief.
6. Connect power cord as follows:
7.Attach ground wire of power cord with the green ground
8. Properly secure power cord to strain relief.
9. Reinstall the cover.
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
screw (hole above strain relief bracket). Tighten all terminal block screws (3) completely.
oow. . oo :j
CONNECTING DRYER USING 3-WIRE CONNECTION
IFREQUIRED,BYLOCALCODE, INSTALLEXTERNALGROUND
(NOTPROVIDED)TO GROUNDED METAL,COLDWATERPIPE,OR GREEN GROUND
OTHERESTABLISHEDGROUND GROUND DETERMINEDBYA QUALIFIED SCREW
ELECTRICIAN. HOT
WIRE
NEUTRAL (White) WiRE
3#10AWGMINIMUMCOPPER
COVER CONDUCTORSOR120/240V30APOWER
SUPPLYCORDKITMARKEDFORUSE WiTHDRYERS&PROVIDEDWITHCLOSED
LOOPORSPADETERMINALSWITH UPTURNEDENDS(NOTSUPPLIED),
1. Turn off the circuit breaker (s) (30 amp) or remove the dryer's
circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall.
3. Remove the power cord cover located at the lower back.
4. Install 3/4 in. UL recognized strain relief to power cord entry hole. Bring power cord through strain relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
6. Be sure ground strap is connected to neutral (center) terminal of block and to green ground screw on cabinet rear. Tighten all terminal block screws (3) completely.
7. Properly secure power cord to strain relief.
8. Reinstall the cover.
, WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
STRAINRELIEF BRACKET
3/4",UL RECOGNIZED
STRAINRELIEF
HOT
EXHAUST iNFORMATION
WARNING- USE ONLY METAL 4-IN. DUCT.
DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
Using exhaust longer than specified length will:
Increase the drying times and the energy cost.
Reduce the dryer life. " Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR RESPONSIBILITY. Problems due to incorrect installation are not covered
by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct, number of turns, the type of exhaust hood (wall cap), and all conditions noted below. Both rigid and flexible metal duct are shown in the table below.
EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
4" 1"_
No. of 90° Rigid Flexible Rigid Ftexible
Elbows Metal Metal Metal Metal
0 90 Feet 55 Feet 60 Feet 45 Feet
1 60 Feet 40 Feet 45 Feet 30 Feet
2 45 Feet 30 Feet 35 Feet 20 Feet
3 35 Feet 20 Feet 25 Feet t5 Feet 4 25 Feet 15 Feet t 5 Feet 10 Feet
If using flexible metal duct, please refer to page 5.
EXHAUST SYSTEM CHECK LiST
HOOD OR WALL CAP
Terminate in a manner to prevent back drafts or entry of birds or
other wildlife.
Termination should present minimal resistance to the exhaust air flow
and should require little or no maintenance to prevent clogging.
Never installa screen in or over the exhaust duct. Thiscouldcauselintbuildup. , Wall caps must be installed at least 12in. above ground level or any other
obstruction with the opening pointed down.
" If roof vents or louvered plenums are used, they must be equivalent to a
4-in. dampened wall cap in regard to resistance toair flow, prevention of back drafts, and maintenance required to prevent clogging.
SEPARATION OF TURNS For best performance, separate all turns by at least 4 ft. of straight duct,
including distance between last turn and exhaust hood.
TURNS OTHER THAN 90°
One turn of 45 ° or less may be ignored.
Two 45° turns should be treated as one 90 ° turn. "Each turn over 45oshould be treated as one 90° turn.
SEALING OF JOINTS
All joints should be tight to avoid leaks. The male end of each section of
duct must point away from the dryer.
Do not assemble the ductwork with fasteners that extend into the duct. They will serve as a collection point for lint.
Ductjoints can be made air and moisture-tight by wrapping the overlapped joints with duct tape.
Horizontal runs should slope down toward the outdoors 1/2 inch per foot
INSULATION
Duct work that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint build-up.
3
Use only for short
run installations
4" DIA,
q _-2.1f'z"
Installation instructions
EXHAUST CONNECTION
_WARNING - TO REDUCE THE RISK
STANDARD REAR EXHAUST
{Vented above floor level)
OF FIRE OR PERSONAL INJURY:
This dryer must be exhausted outdoors.
Use only metal duct.
Do not terminate _'xhaust in a chimney, any gas vent, under an enclosed floor (crawl space), or into an attic.
The accumulated lint could create a fire hazard.
- Provide an access for inspection and cleaning of the exhaust system, especially at turns. Inspect and clean at least once a year,
o Never terminate the exhaust into a common duct with a
kitchen exhaust. A combination of lint and grease could create a fire hazard.
Do not obstruct incoming or exhausted air.
THiS DRYER COMES READY FOR REAR EXHAUSTING. iF SPACE iS LIMITED, USE
THE iNSTRUCTIONS iN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET.
STANDARD REAR EXHAUST
(Vented at floor level)
ELBOWHIGHLY
RECOMMENDED
RECOMMENDED CONFIGURATION
TOMINIMIZE
EXHAUST BLOCKAGE.
ELBOWHIGHLY RECOMMENDED
NOTE: ELBOWS WiLL PREVENT DUCT KiNKiNG AND COLLAPSING.
[_ LEVELING AND STABiLiZiNG
YOUR DRYER
STANDTHEDRYERUPRIGHTNEARTHEFINALLOCATIONANDADJUST THE4LEVELINGLEGS,ATTHECORNERS,TOENSURETHATTHEDRYER
iSLEVELFROMSiDETOSIDEANDFRONTTOREAR.
FORSTRAIGHT LINEiNSTALLATiON,
CONNECTTHE DRYEREXHAUST
TOTHEEXTERNAL EXHAUSTHOODUSING
DUCTTAPEORCLAMP.
--: (CORDNOTSUPPLIED
:"" WITHDRYER)
CUTTHEMETALEXHAUST DUCT(NOTSUPPLIED)TOTHE
PROPERLENGTH.
NOTE:WESTRONGLYRECOMMENDSOLIDMETALEXHAUSTDUCTING. HOWEVER,IFFLEXIBLEDUCTINGISUSEDITMUSTBEMETALNOTPLASTIC.
LEVEL FRONT-TO-BACK. LEVEL
"_ SIDE-TO-SiDE.
4LEVELING
LEGS
installation instructions, indoor
Exhausting
USING FLEXIBLE METAL DUCTS
If rigid all-metal duct cannot be used, then flexible all-metal ducting
can be used, but it will reduce the maximum recommended duct
length. In special installations when it is impossible to use only metal ducting, then UL-listed clothes dryer flexible metal transition
duct may be used as transition venting between the dryer and wail
connection only. The use of this ducting will affect dry time,
tf flexible transition duct is necessary, the following directions must be followed,
Use the Shortest Length Possible.
Stretch the Duct to Its Maximum Length to avoid kinks.
- Do Not Crush or Collapse the Duct.
Never Use Transition Duct Inside the Wall or Inside the Dryer.
. Avoid Resting the Duct on Sharp Objects.
- Venting Must Conform to Local Building Codes.
[] ALCOVE OR CLOSET iNSTALLATiON
- If your dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back.
*The dryer MUST be vented to the outdoors. See the
EXHAUST INFORMATION sections 3 & 4.
, Minimum clearance between dryer cabinet and adjacent
walls or other surfaces is:
0 in. either side 3 in. front and rear
, Minimum vertical space from floor to overhead cabinets,
ceiling, etc. is 52 in.
, Closet doors must be louvered or otherwise ventilated and
must contain a minimum of 60 sq. in. of open area equally distributed. If the closet contains both a washer and a
dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
i ..........................
[] BATHROOM OR BEDROOM
iNSTALLATiON
"The dryer MUST be vented to the outdoors. See
EXHAUST INFORMATION section 3 & 4.
The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRI- CAL CODE, ANSI/NFPA NO. 70.
ELBOWHIGHLY
DONOTUSE EXCESSIVE
EXHAUST
ELBOWSHIGHLY
[] MOBILE OR MANUFACTURED
HOME iNSTALLATiON
, Installation must conform to the MANUFACTURED
HOME CONSTRUCTION & SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard is not
applicable, with AMERICAN NATIONAL STANDARD FOR MOBILE HOME, ANSI/NFPA NO. 50lB.
- The dryer MUST be vented to the outdoors with the termination securely fastened to the mobile home
structure. (See EXHAUST INFORMATION section 3 & 4.)
The vent MUST NOT be terminated beneath a mobile or manufactured home.
, The vent duct material MUST BE METAL.
Do not use sheet metal screws or other fastening devices which extend into the interior of the exhaust vent.
- See section 2 for electrical connection information.
i
5
installation instructions
WARNING- BEFORE PERFORMING
THIS EXHAUST INSTALLATION, BE SURE
TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY. PROTECT YOUR
HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET.
BE SURE TO WEAR GLOVES
REMOVE SCREW ANDSAVE.
REMOVE DESIRED KNOCKOUT (ONEONLY).
Detach and remove the bottom, right or left side knockout
as desired. Remove the screw inside the dryer exhaust duct and save. Pull the duct out of the dryer.
FIXINGHOLE
ADDING NEW DUCT
FIXING HOLE
PORTION"A"
RIGHTOR LEFTSIDE
EXHAUST
Reconnect the cut portion (A) of the duct to the blower housing. Make sure that the shortened duct is aligned with
the tab in the base. Use the screw saved previously to secure the duct in place through the tab on the appliance base.
ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT
SiDE OF CABINET
Preassemble 4" elbow with 4" duct. Wrap duct tape around joint.
- Insert duct assembly, elbow first, through the side opening and connect the elbow to the dryer internal duct.
CAUTION: Be sure not to pull or damage the
electrical wires inside the dryer when inserting the duct.
i .............................
i; ............................. B i A
Cut the duct as shown and keep portion A.
TAB LOCATION
BENDTAB UP45°
Through the rear opening, locate the tab in the middle of the appliance base, Lift the tab to about 45 ° using a flat
blade screwdriver.
BEADDEDTO LEFTORRIGHTSIDE
EXHAUSTCAN
\
Apply duct tape as shown on the joint between the dryer
internal duct and the elbow.
DUCT
CAUTION:
internal duct joints must be
TAPE
they may separate and cause
_ secured with tape, otherwise
6
a safety hazard.
zJ
A°pCT
installation
instructions
ADDING ELBOW FOR EXHAUST THROUGH BOTTOM-OF CABINET
- Insert the elbow through the rear opening and connect it to the dryer internal duct.
*Apply duct tape on the joint between the dryer internal
duct and elbow, as shown on page 6.
CAUTION: Internal duct joints must be secured with tape,
otherwise they may separate and cause a safety hazard.
ADDING COVER PLATE TO REAR OF CABINET (SIDES AND BOTTOM EXHAUST)
CHANGING DiRECTiON OF
DOOR OPENING
1. Open the door and remove the filler plugs opposite the hinges. With the door completely open, remove the bottom screws from each hinge on the dryer face• Insert these screws about half way into the TOP holes, for each hinge on the opposite side (where you removed the filler
plugs). Apply firm pressure to get the screw started.
2. Loosen the top screws from each hinge on the dryer face half way. With one hand holding the top of the door and
the other hand holding the bottom, remove the door from the dryer by lifting it UP and OUT.
3. Rotate the door 180°. Insert the door on the opposite side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step 1.
4. Remove the remaining screws from the side of the opening from which the door was removed. With these screws secure each hinge at the bottom. Tighten the two top screws on each hinge. Reinsert the plastic plugs on
the side from which the door was removed.
REMOVETHE BOTTOMSCREW FROMEACHHINGE ONTHEDRYER
LOOSENTHETOP SCREWSFROM EACHHINGEON
THEDRYERFACE
HALFWAY.
PLATE
(KITWE1M454)
Connect standard metal elbows and ducts to complete the exhaust system. Cover back opening with a plate (Kit WE 1M454) available from your local service provider.
Place dryer in final location.
_ILWARNING _EVER LEAVE THE BACK I
|OPENING WI_O_ THE PLATE,_t
500AI87P044 2 01 ON Pub # 31 16073
__FACE.
MOVETHEDOORIN AND
DOWNUNTILTHETOPHINGE ANDTHEBOTTOMHINGEARE
RESTtNGONTHETOPSCREWS
INSERTEDIN STEP1.
SECUREEACHHINGE ATTHEBOTTOMAND TIGHTENTHETWOTOP SCREWSOFEACHHINGE.
[] SERViCiNG
,_L WARNING- LABEL ALL WIRES
PRIOR TO DISCONNECTING WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION AFTER
SERVICING/INSTALLATION.
For servicing phone numbers for replacement parts, and other information, refer to Owner's Manual or visit our Web site.
7
Notes