I stallatio
30" SealedGasCooktop
I structio s
r_ In Canada, call 1.800.561.3344 or Visit our Website at: www.geappliances.ca
i Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com
IN THE COMMONWEALTH OF
PGP953, PGP959, CGP350
FOR YOUR SAFETY:
MASSACH USETTS:
AWARNING - iftheinformation
, This product must be installed by a licensed
plumber or gas fitter.
, When using ball-type gas shut-off valves, they
shall be the T-handle type.
, A flexible gas connector, when used, must not
exceed 3 feet.
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
.IMPORTANT - Savetheseinstructions
for local inspector's use.
, IMPORTANT - Observeallgoverning
codes and ordinances.
, Note to Installer- Be sure to leave these
instructions with the Consumer.
Note to Consumer - Keep these instructions for
future reference.
, Product failure due to improper installation is not
covered under the Warranty.
in this manual is not followed exactly, a fire,
explosion or gas leak may result causing
property damage, personal injury or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance!
WHAT TO DO IFYOU SMELL
GAS:
Do not try to light any appliance. Do not touch
any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
, If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
i
AWARNING - Thisappliancemust be
properlygrounded.
. IMPORTANT - Leak testingofthe
applianceshallbe conducted accordingto the
manufacturer's instructions.
, Proper installation is the responsibility of the
installer and product failure due to improper
installation is NOT covered under warranty.
WARN ING - Disconnectallelectrical
power at the main circuit breaker or fuse box
before installing.
31-i0807-2 (09-11GE) 1
This cooktop has been certified by UL. You'll find
safety precautions in your Owner's Manual.
Read them carefully.
Installation of this cooktop must conform with
local codes or in the absence of local codes with
the National Fuel Gas Code, ANSI Z223.1/NFPA
54-Latest edition.
Be sure your cooktop is installed properly by a
qualified installer or service technician.
To eliminate reaching over surface burners,
cabinet storage above burner should be avoided.
Do not install the unit near an outside door or
where a draft may affect its use.
Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS
ELECTRICAL REQUIREMENTS
This appliance must be supplied with the proper
voltage and frequency and connected to an
individual, properly grounded branch circuit,
protected by a circuit breaker or fuse having
amperage as noted on the rating plate.
We recommend you have the electrical wiring and
hookup of your cooktop connected by a qualified
electrician. After installation, have the electrician
show you where your main cooktop disconnect is
located.
Check with your local utilities for electrical codes
which apply in your area. Failure to wire your
cooktop according to governing codes could result
in a hazardous condition.
If there are no codes, your cooktop must be wired
and fused to meet the requirements of the National
Electrical Code, ANSI/NFPA No. 70--Latest edition.
You can get a copy by writing:
National Fire Protection Association
Batterymarch Park
Quincy, P1A 02269
PARTS INCLUDED
2Screws
Regulator
MATERIALS YOU MAY NEED
Joint Sealant Pipe Fittings
CSA-Approved Flexible Gas Line
3/8" Min. ID, 1/2" NPTConnection,
3-foot Maximum Length (Massachusetts Only)
2 Hold
Down Brackets
Shut-Off Valve
In Canada your cooktop must be wired and fused
to meet the requirements of the Canadian Electrical
Code.
Be sure the installation of this product in a mobile
home conforms with the Manufactured Home
Construction and Safety Standard, Title 24 CFR,
Part 3280. If this standard does not apply, you
must follow the standard for Manufactured Home
Installations, ANSI/VCSBS A225.1, or with local
codes where applicable.
You can get a copy of the Federal Standard by
Writing:
Office of Mobile Home Standards
HUD Building
451 7th Street, S.W.
Washington, D.C. 24010
TOOLS YOU WILL NEED
FOR INSTALLATION
Pencil
Saber Saw
Phillips-Head
Screwdriver
Pipe Wrench
Ruler or Straightedge
!/8" Drill Bit & Electric or
Hand Drill
Safety Glasses
Installation Instructions
PRE-INSTALLATION CHECKLIST
When preparing cooktop opening, make
[Z]
sure the inside of the cabinet and the
cooktop do not interfere with each other.
(See section on preparing the opening.)
Remove packaging materials, grate boxes,
@
regulator with literature, and literature
package from the cooktop before beginning
installation.
i/
/i/
Foam
Pac_,_,_///_,_r_/,_ _ _ _ _
Cooktop J
Package
Grate boxes
Remove Installation Instructions from
E1
literature pack and read them carefully
before you begin.
Be sure to place all literature (Owner's Manual,
Installation Instructions, etc.)in a safe place
for future reference.
Make sure you have all the tools and
El
materials you need before starting the
installation of the cooktop.
Your home must provide the adequate
El
electrical service needed to safely and
properly use your cooktop. (Refer to section
on electrical requirements.)
When installing your cooktop in your home,
FF1
make sure all local codes and ordinances
are followed exactly as stated.
Hake sure the wall coverings, countertop
[]
and cabinets around the cooktop can
withstand heat (up to 200°F) generated by
the cooktop.
Installation Instructions
PREPARING THE OPENING
r_] MAINTAIN THE FOLLOWING
MINIMUM CLEARANCE DIMENSIONS
13" IVlAX. Depth of unprotected
I
30" MIN. clearance from
countertop to unprotected
overhead surface
C - NIN. I
clearance from I
cutout to rear
wall
L - MIN.clearance
from cooktop to left
side wall
I
2-1/2" MIN from
cutout to front of
countertop
50" or wider
cabinet base
NOTE: All gas cooktop models require 7/16" free
area below cooktop bottom to combustible material.
L R C
PGP953 3-3/4" 6" 2-1/4"
PGP959 12" 12" 2-7/8"
CGP350 12" 12" 2-7/8"
R - IVllN.clearance
from cutout to right
side wall
18" MIN. height
countertop
to nearest
cabinet on either
side of unit
[]] CUTOUT DIMENSIONS OF
COUNTERTOP
To ensure accuracy, it is best to make
a template when cutting the opening
in the counter.
/8" width cut
[]-] RECOMMENDED GAS SUPPLY
LOCATION FROM BACKWALL
r' Min. From Backwall
Recommended
gas supply
location
From Cutout
Center Line
ALL HORIZONTAL CLEARANCES MUST BE MAINTAINED
FOR A MINIMUM OF 18" ABOVE THE COOKING SURFACE.
[_] OVERALL COOKTOP DIMENSIONS
30- ------j__-21-
]-Z/4"
'"T
19-3/8" q_.._
[_] MAKE SURE WALL COVERINGS,
COUNTERTOP AND CABINETS
AROUND COOKTOP CAN
WITHSTAND HEAT {UP TO 200°F)
GENERATED BY COOKTOP
Wall covering,
cabinets and
countertop must l
withstand heat I
Installation Instructions
iNSTALLiNG THE COOKTOP UNiT
LOCATE ELECTRICAL OUTLET AND
rT]
GAS SHUT-OFF VALVE BENEATH
CABINET
NEVER REUSEOLD
CONNECTORS WHEN
INSTALLING THIS
UNIT.
ShutOff _,H IF''
_Valve --_ j ElectricalOutlet 12"
Install a manual shut-off valve in the gas line in an
easily accessible location outside the cooktop. Be
sure you know how and where to shut off the gas
supply to the cooktop. Install the electrical outlet
12" below the countertop.
[_] PROTECT SURFACE OF COOKTOP
Place a towel or tablecloth onto the countertop.
Lay the cooktop upside down onto the protected
surface.
I_ 7f
_1 LJ
II
i
Below
Countertop
ATTACH BRACKETS TO COOKTOP
Remove the screw from the side of the cooktop
and screw the hold-down bracket
to the side of the cooktop unit. Repeat for opposite
side of cooktop.
Pre-drilled
Bottom of
Cooktop
-1
Cookto
Surface
hole X
r_ INSERT COOKTOP INTO CUTOUT
Insert the cooktop centered into the cutout opening.
Hake sure the front edge of the countertop is
parallel to the cooktop. Hake final check that all
required clearances are met.
Bottom of cooktop j
Cloth under Cooktop
r_ LOCATE MOUNTING PARTS
Remove the hold down brackets from the
literature package.
Once the unit is in place, screw the
hold- down bracket into the cabinet sides
to secure the unit into place.
Installation Instructions
INSTALLATION--GAS CONNECTIONS
r_ PROVIDE ADEQUATE
GAS SUPPLY
This cooktop is designed to operate on natural
gas at 5" of water column manifold pressure and
7" of water column (W.C.) supply pressure. It is
shipped from the factory set for natural gas. The
convertible pressure regulator supplied with the
unit must be connected in series with the manifold
of the cooktop and must remain in series with the
supply line regardless of whether natural or L.P.
gas is being used. FOR PROPEROPERATION, THE
HAXIHUH INLET PRESSURETO THE REGULATOR
HUST BENO HaRE THAN 14" OF WATER COLUHN
PRESSURE.For checking the regulator, the inlet
pressure must be at least 1" W.C.. (or 3.4 KPA)
greater than the regulator output setting. If
the regulator is set for 5" W.C. of water column
pressure, the inlet pressure must be at least 6" W.C.
If the regulator is set for 10" W.C., the inlet pressure
must be at least 11" W.C.. The gas supply line to
the cooktop should be 1/2" or 3/4" pipe.
J_ INSTALL REGULATOR
NEVER REUSEOLD CONNECTORS WHEN
INSTALLING THIS COOKTOP.
AWARNING: Never reuse old flexible
connectors. The use of old flexible connectors
can cause gas leaks and personal injury. Always
use new flexible connectors when installing a gas
appliance.
Screw a section of pipe onto
the inlet end of the pressure
regulator and install the
coupling.
Pressure __-]
Regulator '_
Coupling _ t_
r3] INSTALL REGULATOR ONTO
BURNER BOX BOTTOM
Screw the regulator
onto the burner
box bottom pipe
connection. Hake
sure the top of
the regulator is
Pressure _1
Regulotor-=---_l
facing towards the
cabinet front, easily
accessible through
the cabinet doors.
The regulator may
also be installed
Coupling l
LI
:\
Ii Electrical
II Outlet 12"
I Below
Countertop
prior to inserting
the cooktop into the cutout if extreme caution is
used to ensure the regulator connection is not
compromised.
r_ COMPLETE CONNECTION WITH A
COUPLING
Complete the
connection between
the regulator pipe
coupling and
the shut-off valve.
Pressure
Regulator
Coupling
Shut-Off _7
Valve
I
II
II Electrical
I Outlet 12"
I Below
Countertop
To reduce the likelihood of gas leaks, apply teflon
tape or a thread compound approved for use with
LP or Natural gases to all threaded connections.
Installation Instructions
[_ CHECK FOR LEAKS
LEAKTESTINGOF THE APPLIANCE SHALL BE
CONDUCTED ACCORDING TO THE MANUFACTURER'S
INSTRUCTIONS.
Before testing for leaks, make sure all burner knobs
are in the OFF position.
After connecting the cooktop to gas, check system
for leaks with a manometer. If a manometer is not
available, turn the gas supply on to the cooktop
and use a liquid leak detector at all joints and
connections to check for leaks.
Tighten all connections if necessary to prevent gas
leakage in the cooktop or supply line.
DO NOT USE OPEN FLAME TO CHECK FOR
LEAKS!
Disconnect the cooktop and its individual shut-off
valve from the gas supply piping system during any
pressure testing of that system at test pressures
greater than 1/2 psig (3.5 kPa).
Isolate the cooktop from the gas supply piping
system by closing its individual shut-off valve
during any pressure testing of the gas supply
system at test pressures equal to or less than 1/2
psig (3.5 kPa).
[_] INSTALLATION OVER BUILT-IN
OVEN
See built-in oven installation for complete
installation instructions.
1
5" To Center of
2" Dia. Hole From
Countertop
90° Elbow
2" Dia. Hole
(20 7/8" from front
of Countertop to
Hole Center)
View from Front of Cooktop
Installation Instructions
INSTALLATION--ELECTRICAL CONNECTIONS
AWARNING - Disconnecto11electricol
power ot the main circuit breoker
or fuse box before instolling.
ELECTRICAL SUPPLY AND OUTLET
An odequote electricol supply ond outlet must
be used to operote the electricol ports of your
cooktop.
[]
The power cord of this appliance is equipped
with o 3-prong (grounding) plug which must
be used with u properly grounded I-hole
outlet with o standard 120 Volt, 60 cycle AC
household current.
B]
If you do not hove o I-hole grounded outlet,
hove o quolified electrician chonge your old
one. DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND) PRONG
FROM THE POWER CORD. DO NOT USE AN
ADAPTER. DO NOT USE AN EXTENSION CORD.
Insure proper
ground and
firm connection
before use
Installation Instructions
COOKTOP BURNERS
E_ ASSEMBLING THE COOKTOP BURNERS
The electrode of the igniter is exposed. Be careful not to turn on any cooktop controls
while the top of the burner is removed. Do not remove the top or touch the electrode
of any burner while another burner is turned on. Electrical shock might result.
[] Place the burner head onto the burner base. Hake sure to place the correct
burner head on the correct burner base and that the burner head sits level on
the burner base. The burner heads are not interchangeable. Ensure the slot in
the burner head is positioned over the electrode and that the burner head is
fully inserted inside the burner base. A small gap between the base and head is
normal.
Place the burner caps on the burner heads, making sure to place the correct
[]
burner cap on the correct burner head. The burner caps are not
interchangeable. Each cap has three to four pins. Hake sure that the burner
caps are properly seated on the burner heads and that none of the pins sit in the stability chamber.
OR
Burner
base base
{\ '7 Burner
Burner cap properly seated
Burner cap not properly seated
J
[_ CHECK IGNITERS
Operation of the electric igniters should be checked after the cooktop and supply line have been carefully
checked for leaks and the cooktop has been connected to the electrical power.
On models so equipped, check to be sure the cooktop is in the UNLOCKED position.
r_ Push and turn a burner valve to the LITE position. All spark igniters will make a series of sparks (ticking
sounds), but only the burner turned to LITE will light.
. The burner should light when gas is available to the burner.
. Once the burner lights, it should be turned out of the LITE position.
r_ Try each valve separately until all burners have been checked.
Installation Instructions
COOKTOP BURNERS (CONT.)
ITI BURNER IGNITION
Cooktop Spark Ignition-When you turn
the cooktop knob to LITE,the spark igniter makes a
series of electric sparks (ticking sounds) which light
the burner. During a power failure, the burners will
not light automatically. In an emergency, a cooktop
burner may be lit with a match by following the
steps below.
On models so equipped, check to be sure the
cooktop is in the UNLOCKED position.
rA1 Light a match and hold the flame near the
burner you want to light. Wooden matches
work best.
r_ Push in and turn the control knob slowly. Be
sure you are turning the correct knob for the
burner you are lighting.
NOTE: If the burner does not light within five seconds,
turn the knob off and wait one minute before trying
again.
[_] BURNER GRATES
The three cooktop grates are designed for specific
positions. For maximum stability, these grates
should only be used in their proper position with
the edges positioned on top of the black bumpers
as shown
/
/
/
/
Grate
//
/'
//
/'
/
/
//
/
/
Black Grate
Bumpers
[_ THE BURNER FLAMES
Turn each burner on. Flames should be blue in color
with no trace of yellow. The burner flames should
not flutter or blow away from the burner. The flame
should be no less than 1/4" on the lowest setting
,_ great er thanand1-1/2" on highest setting.
nCAUT/ON: Ifyou attempt to measurethe
flame, please use caution. Burns could result.
i/4" to
i-i/2"
Burners should be checked frequently
Cooktop Burner
10
Installation Instructions
OPERATION CHECKLIST
r_ Make sure all controls are left in the OFF r_
position. Check to be sure the cooktop is in the
UNLOCKED position (on models so equipped).
Make sure the flow of air to and from the
cooktop is unobstructed.
The serial plate for your cooktop is located on
the bottom of the burner box. In addition to the
model and serial numbers, it tells you the ratings
of the burners and the type of fuel and pressure
the cooktop was adjusted for when it left the
factory.
EEl
When ordering parts, always include the serial
number, model number and a code letter to
ensure proper replacement parts.
Recheck Steps:
Double check to make sure everything in this
guide has been completed. Rechecking steps
will ensure safe use of the cooktop.
11
Installation Instructions
MAKING THE LP CONVERSION
r]-] SAFETY INFORMATION YOU
SHOULD KNOW
The pressure regulator and burner orifices are set
for natural gas. To use LP gas, the regulator and
burner orifices must be converted. The LP orifice
spuds for the cooktop burners can be located in the
literature package attached to the regulator.
A ,,-.^, ,-T-, ,.._L,
,JJLL,,/'_M/IUi_I: The cooktop, as shipped from
the factory, is set for use with natural gas. If you
wish to use your cooktop with LP gas, you must
first replace the orifices and convert the pressure
regulator.
Ai i m^_,,,,,,,,_
_I_W/"_KI_I I i_1!_: This conversion must be
performed by a qualified installer or gas supplier in
accordance with the manufacturer's instructions
and all codes and requirements of the authority
having jurisdiction. Failure to follow instructions
could result in serious injury or property damage.
The qualified agency performing this work assumes
responsibility for the conversion.
ACAUTION: The followingadjustments
must be made before turning on the burner. Failure
to do so could result in serious injury. Be sure
pressure regulator has been converted as
described in Step 2.
TOOLS YOU WILL NEED
FOR LP CONVERSION
7ram Nutdriver
Safety Glasses
Small Flat-Head
Screwdriver (4mm or
5/]2" tip size, 60ram
long)
ADJUST YOUR COOKTOP FOR USE
[2]
WITH LP GAS
[]
Disconnect all electrical power, at the main
circuit breaker or fuse box.
Shut off the gas supply to the cooktop
by closing the manual shut-off valve.
[]
Adjust the pressure regulator, by the following
instructions:
. Unscrew the cap
* Place your thumb against the flat side of the
spring retainer and press down to remove
the retainer.
12
* Carefully look at the spring retainer to locate
the NAT or LP position.
Cap Gasket
NAT
Position Position
Pressure Regulator
* Turn the spring retainer over so that LP is
showing on the bottom.
* Snap the retainer back into position.
* Screw the cap back onto the regulator.
Installation Instructions
MAKING THE LP CONVERSION (CONT.)
[_ CHANGE COOKTOP BURNER
ORIFICES
FA] Remove the grates, burner caps, and burner
heads.
r_ using a 7mm nut driver, remove the burner
orifices. These may be accessed through the
burner holes in the cooktop.
Inner /.,_,(_ /f¢_ Burner
burner cop
Burner ,S_ Outer OR \_ cop
bose -__'_ burner _Burner
Electrode Burner base
Orifice spuds located J/ Orificespud located Electrode
through these openings through this opening
Tri-Ring Burner
_ etainer
Fc] Locate the LP/Propane orifices shipped inside
the literature package. They will have a digit
number and the letter "L" on the side.
(IMPORTANT: Save the orifices removed from
the appliance for future use.)
Each orifice will show a series of engraved
marks, (I, II, IV or V), located on the top.
These marks denote the location of each orifice to the
cooktop burner.
cap Burner head
NOTE: On all burners, the
Ring
orifices have a spring-loaded
retaining ring around the hex
head to hold the orifice in the
nut driver during installation
and removal. A slight amount
of force is required to push the
nut driver down over the ring.
r_ CHANGE COOKTOP BURNER
ORIFICES (CONT.}
CENTER BURNER
15,000 BTU/hr Extra Large Burner (PGP953 Models)
Cap
Burner
Set Screw
I
7,1 ,-1
_,_ Choke
I
I
Burner
Head
Extended spud for center
extra large burner
Spud
Extended
Base
Orifice spud located
through this opening
For PGP953Models
For PGP959& CGP350 Models
See instructions
for center burner
13
Installation Instructions
[T_ CHANGE COOKTOP BURNER
ORIFICES (CONT.)
CENTER BURNER
20,000 BTU/hr Tri-Ring Burner (PGP9S9 and CGP3SO
Models)
spuds located
through these
openings.
Main Orifice
Main Orifice
Simmer Orifice
Main Orifice
_] CHANGE COOKTOP BURNER
ORIFICES (CONT.)
LEFT FRONT BURNER
(PGP959 and CGP350 Models)
Griddle Screw
The griddle screw
is marked with N
for natural gas
and L for liquefied
petroleum.
Main Orifice
NOTE: The main orifice is located in the center of
the burner, while the griddle screw is located to the
right of the center of the burner.
Install the LPPropane orifices and griddle
[]
screw (on PGPgS9and CGP3S0models only)
in their precise locations as noted in the
earlier illustrations.
r_ Return the natural gas orifices and griddle
screw to the bracket and attach the bracket
and the instruction sheet to the pressure
regulator using the screw removed previously.
r_ Replace the burner heads, caps and grates.
14
Installation Instructions
MAKING THE LP CONVERSION (CONT.}
ADJUST BURNER FLAMES
Turn all burners full on and check the flames.
They should be blue in color with some yellow
tipping at the ends of the flame. Foreign
particles in the gas line may cause an orange
flame at first, but this will soon disappear.
r_ Turn the cooktop burner knob to the lowest
setting while observing the flame.
Adjust the low flame setting using the valve bypass
screw as follows:
Low-setting adjustments must be made with two
other burners in operation on a medium setting.
This prevents the low flame from being set too low,
resulting in the flame being extinguished when
other burners are turned on.
E1 To adjust the flame,
remove the knobs. Use
screwdriver to remove
valve stem plugs as
shown.
Insert a screwdriver
through the access hole
in valve switch. Engage
adjustment screw in
valve. Refer to the Left of stem
illustration below that
matches the adjustment ./
screw location for
your model. The
griddle burner (PGP959
and CGP]50) has 2
adjustment screws,
one for the left rear
burner and one for the
left front burner during
griddle control. Griddle
control must be turned
to LOwhen making this
adjustment.
, If the flames were too
small or fluttered, open
the valve more than the original setting.
For left front griddle
burner and tri-ring
burner simmer
adjustment screw
For all burners
except tri-ring
r_ Testing Flame Stability:
Test 1 - Temporarily replace knobs. Turn the
knob from "HI" to the lowest setting
quickly. If the flame goes out at the
lowest setting, increase the flame size
and test again.
Test 2 -
El Flame Recheck:
After the adjustment is made, turn all burners off.
Ignite each burner individually. Observe the flame
at the "HI" position. Rotate the valve to the lowest
setting and be sure that the flame size decreases
as the valve is rotated counterclockwise.
TO CONVERT THE COOKTOP BACK TO NATURAL
GAS, REVERSETHE STEPSUNDER MAKING THE LP
CONVERSION.
Once the conversion is complete and checked ok,
replace valve stem plugs and knobs, and fill out
the LP sticker. Include your name, organization and
date conversion was made. Apply the sticker near
the cooktop gas inlet opening to alert others in
the future that this appliance has been converted
to LPgas. If converting back to natural gas from
LP, please remove the sticker so others know the
appliance is set to use natural gas.
With the burner on the lowest setting,
open and close the cabinet door
under the cooktop. If the flame is
extinguished by the air currents
created by the door movement,
increase the flame height and test
again.
, If the flames blew away from the burner,
close the valve more than the original
setting.
B] Make the adjustment by slowly turning the
screw until flame appearance is correct.
15