GEPppliances.com
Safety Instructions ............. 2, 3
Operating Instructions
Controls ...................... 4-6
Care and Cleaning
Air Filter ........................ 6
Otltdoor Coils .................... 6
Installation Instructions ....... 7-10
Troubleshooting Tips ........... 11
Normal Operating Sounds ........ 11
Consumer Support
Consumer Support ....... Back Cover
Ownership Registration for
Customers in Canada only ..... 13, 14
Warranty for Customers
in Canada ...................... 16
Warranty for Customers
in the U.S.A..................... 15
AKWI O*
AKWI 2 *
AKZIO*
AKZI2*
Climadseur
La section fran_'aise commence ?_la page 17
Acondicionador
o
de alre
<
*ENERGY STAR ® labeled product
ENERGYSTAR
As an ENERGY STAR®partner; (;E has
determined fllat this product meets
tile ENERGY STAR®guidelines for
energ}, ef_icienc>
Write themodelandserial numbers here:
Model #
Serial #
Find these numbers on a label on tile
side of tile air conditioner
In Canada, contact us at:
www.GEAppliances.ca
La secci6n en espa_ol empieza en la pdgina 33
49-7629 12-09JR
IMPORTANTSAFETYINFORMATION.
READALLINSTRUCTIONSBEFOREUSING
m
For your safety, the information in this manual must be followed tominimize the risk of fire, electric shock
or personal injury,
SAFETYPRECAUtiONS
}} Use this appliance only fi)r its intended }}
purpose as described in this Owner's
Manual.
iii}i}i
This air conditioner must be properly
installed in accordance with the Installation
Instructions before it is used.
iii}i}}li_
Never unplug your air conditioner by pulling
iii}i}i
on the power cord. Alwaysgrip plug firmly
and pull straight out from the receptacle.
iii}i}}li_
Replace immediately 'allelectric sen,ice
iii}i}}li_
cords that have become flayed or other_dse
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained from the manufhcturer and
iii}i}}li_
not repaired. Do not use a cord that shows
cracks or abrasion damage along its len_h
or at either the plug or connector end.
iiiH}}ii{_
Turn the unit OFFand unplug your air
conditioner befi)re cleaning.
iii}i}}li_
GE does not support any servicing of the air
conditioner. _% strongly recommend that
you do not attempt to ser_;ice the air
conditioner yourseff,
For your safety...do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the x,icinity
of this or any other appliance.
All air conditioners contain refligerants,
which under federal law must be removed
prior to pro&lct disposal, ffyou are getting
rid of an old product _dth refrigerants,
check ;_dththe company handling disposal
about what to do.
ff the receptacle does not match the plug,
the receptacle must be changed out by a
qualified electrician.
These 1),410A air conditioning systems
require contractors and technicians to
use tools, equipment and saIety standards
approved for use with this refligerant.
DO NOT use equipment certified fbr
1_222refligerant only.
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord,
For personal safety, this appliance must be
properly grounded,
DONOT use an adapter plug with this appliance.
The power cord of this appliance is equipped
_dth a 3-prong (grounding) plug which mates
_dth a standard &prong (grounding) wall
oudet to minimize the possibility of electric
shock hazard from this appliance.
Power cord includes a current interrupter
dex,ice. A test and reset button is prox,ided on
the plug case. The dex;ice should be tested on a
periodic basis by first pressing the YESYbutton
and then the RESEYbutton while plugged into
the outlet. If the TESrbutmn does not trip
or it the RESETbutmn _dll not stay engaged,
discontinue use of the air conditioner and
2
contact a qualified serx,ice technician.
Have the wall outlet and circuit checked by
a qualified electrician to make sure the outlet
is properly grounded.
Where a 2-prong wall outlet is encounmred,
it is your personal responsibility and obligation
to have it replaced with a properly grounded
3-prong wall oudet.
The air conditioner should always be plugged
into its own indix,idual electrical outlet which
has a voltage rating that matches the rating
plate.
This prox,ides the best perfbrmance and also
prevents overloading house wiring circuits
which could cause a fire hazard from
overheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electrical
connection requirements.
WA
USEOFEXTENSIONCORDS--775-Voltmodelsonly
GEApp/iance&com
Because of potential safety hazards under certain
conditions, we strongly recommend against the
use of an extension cord.
However, if you must use an extension cord,
it is absolutely necessary that it be a UL-listed,
14-gauge, 3-wire grounding-type appliance
exmnsion cord having a grounding-type plug
and outlet and that the electrical rating of the
cord be 15 amperes (minimum) and 125 volts.
.4,CAUTION:
DONOTusean extensioncord withanyofthe
230/208voltmodels.
READANDFOLLOWTHISSAFETYINFORMAtiONCAREFULLY.
SAVETHESEINSTRUCTIONS
3
About the controls on the air conditioner.
Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings,
Lightindicatesthe unit
isintemperature or
delaytime Set mode.
NOTE:The display always shows the
room temperatureexcept when setting
the Settemperatureor the Delaytimer
Delaytimerand 2 Z ..................i I _:TL"_ 1
temperature set _ _ I I_ 0_I
Decrease/Increase Power
Dele_
Light indicatesthe
delaytimer isset.
Air Conditioner Controls Remote Control
Delay1-24hr e I (}Mod}e<O_
Modeselect
@
Unit poweron/off
Auto Fanon/off and
Decrease/Increase
j
Controls
O ower Pad
Tmns air conditioner on and off. _;hen
aimed on, the display will show the room
temperature.
Dis#aF
Shows die room temperature or time
remaining on the Dela} timex: Shows the Set
mmperamre while setting the temperature in
Cool or Energy Saver modes. The Set light will
mrn on while setting.
NOTE:The display will change to show the
room temperature afker settings have been
made. To recall the Sat temperature, press the
TampIncrease A or Decrease V pads.
Tamp/ncrease A / Decrease T Pads
@
Use to set temperature when in Cool or Energy
Savarmode. The Set light will turn on while
setting. HeM do_ both the up and down
pads for 5 seconds to change the display
between Fahrenheit and Celsius.
O Delay 7imerIncrease A /Decrease V Pads
Each touch of the Increase A/Decrease Y
pads on the unit or on the remote control will
set the dela}, time when using the Delay #-24hr
fimeI: The Set light will mrn on while setdng.
Fan Speed Pad
Use to set the fan speed to LOw, Met/, H_gh
or AUtOon the unit. NOTE:On the remote
control, use the Fan button to set the fan
speeds to #=0141,Me_ MiD#or Auto.
O ode Pad
Use to set the air condidoner to Cool, Energy
Saveror Fanmode.
Delay Pads
0
Delay ON--When the air conditioner is off:; it
can be set to automatically come on in 1 to 24
hours at its previous mode and fan settings.
Delay OFF--When tlle ah conditioner is on,
it can be set to automaticNly mrn off in 1 to
24 hom_.
Hew to set
Press die Delay 1-24hrpad on the unit or on
the remote control. Each touch of the Increase
A/Decrease V pads on file unit or on file
remora conUol will set the diner in 1/2-hem
intetwa/s tmfil the time reaches l0 hom_; then
it will increase in 1-hour inmrva/s. The Sat
light will mrn on while setting.
To review the remaining dine on the Belay
1-24hr time_; press the Delay 1-24hr pad on
the unit or on the remote control. Use the
Increase A/Decrease V pads on the unit or
on the remote control to set a new time if
desired.
Tocancel thetimer, press the Delay #-24hr pad
until the light on the Delay1-24hrpad goes off.
4
Clean Filter
The "Clean Filter" light will come on to tell you it is
time to change your filter
Oo Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for
fleezing outdoor conditions. It must not be used in
fleezing outdoor conditions°
Remote Control
To ensure proper operation, aim file reItlote
control at the signal receiver on the air
conditioner
The remote conuol signN has a range of
up to 20 feet.
CoolMode
Use the Coo/mode at tow, Met/, High or Auto Fan
Speed for cooling. Use the TemperatureIncrease A /
Decrease Y pads to set the desired temperature
between 62°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the
room mmperamre. The compressor will cycle on
and off to keep the room at the set level of comfort.
Set the them_ostat at a lower number and the indoor
air will become cooler Set the themlostat at a higher
number and the indoor air will become wam_e_:
NOTE:If the air conditioneris offend is then turned on
while set toa Cool setting orif turnedfrom a fan setting
toa Cool setting, it may takeapproximatdg 3 minutes
forthe compressorto startand cooling tobegin.
GEApp/iances.com
Make sure noflfing is bet_,veen file air conditioner
and the remora control that could block the
signN.
Make sure baueries are flesh and installed
correctl}. _ksindicated on the remote control.
Cooling Descriptions
For Normal Cooling--Select the Coolmode and
High or Med tim with a middle set temperature.
For Maximum Cooling--Select the Cool mode
and High fan with a lower set mmperamre.
ForQuieter and Nighttime Cooling--Select the
Cool mode and lOW fan with a middle set
temperature.
Energy Saver Mode
Controls the tim.
0N--The fan will cycle on and offwith the
compressor This results in wider variations of room
mmpemmre and humidity. Nomm/ly used when the
room is tmoccupied. NOTE: Thefan 1778}/continueto run
forashort timeafter the compressorcyclesoff
Fan Mode
Use file Fan Mode at Low, Med or High fan speed to
provide air circulation and filtering wiflK_ut cooling.
Since fan-only settings do not provide cooling, a
Set mmperamre cannot be enmred. The room
mmperamre will appear in the display.
AutoFanSpeed
Set to Auto tim speed for the fan speed to
automatically set to the speed needed to provide
opfilntltll COHlf()I't settings with the set mmpemmre.
If the room needs more cooling, the fan speed
will automatically increase. If the room needs less
cooling, the fan speed will automatical1) decrease.
Power Outage Recovery Feature
In the case of a power outage or interruption, the
unit will automatically restart in the settings hst
used after the power is restored. If the Delay 1-24hr
OFF--The tim runs all file time, while the
compressor cycles on and (fie
NOTE."AutoFanSpeedis availablein theFanMode.
NOTE:AutoFanSpeedisavailableintheFanMode.
feature was set, it will resmne cotmtdown. You me}.
need to set a new time if desired.
5
About the controls on the air conditioner.
Additional important information,
Air Direction
Use file lever to adjust file ah direction left and
right on/y:
Fresh Air Vent Control (onsomemode/s)
The Fresh Air Vent Control allows you to let flesh
air into the room.
To open the vent, pull the tab out to Nlow flesh mr
to circulate into the room.
To close the vent, push the tab in.
Careand cleaning of the air conditioner.
Grille and Case
Turn the air conditioner off and remove the plug To clean, use water and a mild detergent. Do not
flom the wall outlet before cleaning, use bleach or abrasives.
Air Filter
The air filter behind the flont gqille shoukt be
checked and cleaned at least eveQ' 30 days or
more oRen if necessaQ'.
TO romove:
Open the inlet grille by pulling dowmvard on the
robs at the top upper corners of the inlet grille until
the grille is in a 45° position. Remove the filter
Clean the filter _dth warm, soapy' water Rinse and
let the filter dQ' befbre replacing it. Do not clean
tlle filter in a dishwasher
U
................m
m ---q-r_m-
!!
Vent open Vent closed
Tab Tab
^,.,CAUTION:_oNoroperatetheairconditioner
without afilter becausedirt and lint will clog it and reduce
performance.
Outdoor Coils
The coils on the outdoor side of die air conditioner
should be checked regularly. If they are clogged
with dirt or soot, they may be profe.ssionNly cleaned.
How to insert the Batteries in the Remote Control
[_] Remove the battery cover by'sliding it
according to the arrow direction.
[-_ Insert new batteries, making sure that the (+)
and (-) of battery are installed correctly.
_ Reatmch the cover by sliding it back
into position.
6
NOTES:
Use 2 "AAA" (1.5 volt) a/kaUne batteries. Do not
use rechargeable batteries.
Remove the batteries fiom the IeIIlOm control if
the sysmm is not going to be used for a long time.
Do not mix old and new batteries. Do not mix
all(aline, smndard (carbon-zinc) or rechargeable
(hi-cad, ni-mh, etc.) batte,ies.
I stall ti
Ai Conditio
structi
_ Questions? Call 800.GE.CARES (800.432.2737) orVisit ourWebsite at: GEAppliances.com
i m
in Canada, call 1.800.561.3344 or visit www.GEAppliances.ca i
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
• IMPORTANT - Savethese
instructions for local inspector's use.
• IMPORTANT - Observe
governing codes and ordinances.
• Note to Installer- Be sure to leave these
instructions with the Consumer.
• Note to Consumer- Keep these
instructions for future reference.
• Skill level - Installation of this appliance
requires basic mechanical skills.
• Completion time- Approximately 1 hour
• We recommend that two people install
this product.
• Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under the Warranty.
You MUST use all supplied parts and use
proper installation procedures as described
in these instructions when installing this air
conditioner.
-4,CAUTION:
Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.
Do not change the plug on the power cord
of this air conditioner.
Aluminum house wiring may present special
problems--consult a qualified electrician.
TOOLS YOU WILL NEED
Phillips head screwdriver
Flat-blade screwdriver
_) ELECTRICAL REQUIREMENTS
(_ ome models require a 115/120-voltAC,
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall
outlet you plan to use is only a 2-prong outlet,
it is your responsibility to have it replaced with
a properly grounded 3-prong wall outlet.
©
60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
Some models require 230/208-volt AC,
protected with a time-delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for
best performance and to prevent
overloading house or apartment wiring
circuits, which could cause a possible
fire hazard from overheating wires.
Pencil Ruler or tape measure
Level Scissors or knife
Power cord includes a current interrupter
device. A test and reset button is provided on
the plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the RESET button while plugged into
the outlet. If the TEST button does not trip or
if the RESET button will not stay engaged,
discontinue use of the air conditioner and
contact a qualified service technician.
7
PARTS iNCLUDED
{Appearance may vary)
Top mou_
Air
conditioner
Installation instructions
_e window
w,F aw ;
Left
accordion
panel
al
Right
accordion
panel
/
L
3/8" Type A (4)
If top rail is not
already attached
3/4" Type B (6) Window locking
bracket (1)
8
Frame locking
bracket (2)
Installation instructions
m WINDOW REQUIREMENTS
• These instructions are for a standard double-
hung window. You will need to modify them
for other types of windows.
• The air conditioner can be installed without
the accordion panels if needed to fit in a
narrow window. See the window opening
dimensions.
• All supporting parts must be secured
to firm wood, masonry or metal.
• The electrical outlet must be within reach of
the power cord.
• Follow the dimensions in the table and
illustration for your model.
Models A B
AKW 10, A KZ 10 16" 23"-3 8 1/8"
AKW12, AKZ12
[3===43
_w
A
,_ B
(With accordion panels)
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will
keep it from draining properly.
To adjust for this, attach a piece of wood to
the sill.
WOOD PIECES
WIDTH: 2"
LENGTH: Long enough to fit inside the
window frame.
THICKNESS: To determine the thickness, place
a piece of wood on the sill to make it 1/2"
higher than the top of the storm window
frame or the vinyl frame.
Attach securely with nails or screws provided
by the installer.
/
1/2" higher
than vinyl frame
L (on some windows)
[] PREPARE THE AIR CONDITIONER
[] If not already attached, install the top
mounting rai! with 4Type A screws from
the outside of the case.
Top mounting rail
_3
Bottom
mounting rail
[] Hold the accordion
panel in one hand and
gently pull back to free
the open end.
[]
Slide the free end of the accordion panel
into the side panel rails. Slide the panel
down. Be sure to leave enough space to
slip the top and bottom of the frame into
the rails on the cabinet.
NOTE:There is a right and a left accordion
panel. Be sure to use the proper panel for
each side.
Slide the left and right accordion panels
into the top and bottom mounting rails.
Top mounting rail Top right
Top left
1/2" higher _ ____[;T _)j_Wood
than stormframewindow__/S' _ J//rr_i
Storm window
frame _ r'_ Vinyl frame I !
9
Bottom mounting rail
Installation instructions
[] PREPARE THE WINDOW
Cut the window sash seal to the proper
length. Peel off the backing and attach the
seal to the underside of the window sash.
INSTALL THE AIR CONDITIONER
[]
IN THE WINDOW
FAq
Place the air conditioner on the sill with
the bottom mounting rail against its back
edge. Center it and close the window
securely behind the top mounting rail.
It should be level or slightly tilted to the
outside. Use a level; about a 1/3 bubble
will be the correct case slant to the outside.
3 Screws
[]
INSTALL SUPPORT BRACKET AND
FOAM TOP WINDOW GASKET
[]
ACAUTION:
To prevent broken glass
or damage to windows,
on vinyl or other
similarly constructed
windows, attach the
window locking bracket
to the window side jamb.
Attach the window
locking bracket with one
Type B screw.
Cut the foam top window gasket to the
window width.
Stuff the foam
@
between the
glass and the
window to
prevent air and
insects from
getting into the room.
NOTE: If the gasket supplied does not fit
your window, obtain appropriate material
locally to provide a proper installation seal.
Vinyl
Wood
2 Frame locking brackets
[]
Extend the left and right accordion panels
to the vertical window sashes and attach
3Type B screws through the holes in the
upper panels, as appropriate.
@
Install the frame locking brackets between
the bottom of the accordion panel and the
window sill. Attach with 2Type B screws.
NOTE:To prevent the window sill from
splitting, drive the pilot holes before
driving the screws.
10
TroubleshootingTips. aappliances.com
Possible Causes What ToDo
Air conditioner The air conditioner * Make sure the air conditioner plug is pushed
does not start k unplugged, completely into die outlet.
The fuse is blown/circuit _ Check die house fi_se/circuit breaker box and replace
breaker is tripped, the fi_se or reset the breaker:
Power failure. , The unit will automatically restart in the settings last
used after the power is restored.
"There is a protective time del W (approximately
3 minutes) to prevent tripping of the compressor
overload. For this reason, the unit may not start
normal cooling fbr 3 minutes after it is turned
back on.
The current interrupter _ Press the RESEYbutton located on the power cord plug.
device is tripped. "If the RESETbumm will not stay engaged, discontinue
use of the air conditioner and contact a qualified
service technician.
Air conditionerdoes Airflow is restricted, e Make sure there are no curtains, blinds or flnnimre
not cool as it should bkmking the flont of the air condifionen
The tamp control may _ In the Coolmode, press the Decrease Y pad.
not be set correctly.
The air filter is dirty. _ Clean the filter at least every :30 days.
See the Care and Cleaning section.
The room may have been hot. _ When the air conditioner is fi_t turned on, you need
to allow time fbr the room to cool do_L
Cold air is escaping. _ Check for open fi_rnace registe_ and cold air returns.
Cooling coils have iced up. , See "Air conditioner #eezing up" below.
Air conditioner Ice blocks the air flow * Set the controls at HighFan or HighCooland set the
freezing up and stops the air conditioner themlosmt to a higher temperature.
from cooling the room.
Theremote control The batteries are inserted _ Check the position of the batteries. They shouM be
is notworking incorrectly, inserted in the opposite (+) and (-) direction.
The batteries may be dead. e Replace the batteries.
Waterdripsoutside Hot, humid weather. _ This is normal
Waterdripsindoors The air conditioner is not _ For proper water disposal, make sure the air conditioner
tilted to the outside, slants slightly flom the case flont to the lean
Water collects in Moisture removed from air , This is nomlal fbr a short penod in areas with/itde
base pan and drains into base pan. humidity; normal Rn a kruger period in veQ' humid areas.
Normal Operating Sounds
You may hear a pinging noise caused b), water
being picked up and thrown against the
condenser on rainy days or when the humidi b,
is high. This desigm feature helps remove
moisture and improve efficiency.
}_You may hear the thermostat click when the
compressor cycles on and off:
Wamr will collect in file base pan during
high humidity or on rainy days. The water
may overflow and drip flom the outdoor side
of the unit.
}_The tim may run even when the compressor
does not.
//
m
-- Notes.
_ m
_ J2
Please place in envelope and mail to:
Veuillez mettre dans une enveloppe et envoyez _ :
OWHERSHIPREGISTRATIOH
P.O. BOX1780
MISSJSSAUGA,OHTARIO
L4Y4G1
(FORCAHADIAHCOHSUMERSOHLY)
13
For Canadian
Customers
Pour les
Consommateurs
Canadiens
Pleaseregisteryourproducttoenableustocontactyou
intheremoteeventasafetynoticeisissuedforthisproduct
andto aUow for efficient communication under the terms
z:
of your warrant_; should the need arise.
I
REGISTERON-UNE: wvwv, geappliances.ca MAILTO:,
CCI
ENREGISTREMENTSUR INTERNETA: www.electromenagersge.ca POSTERA:
L3_
Z _
[][] MISS/MLLE.MR'/M[][] Ms.MRS'/MME"FIRSTNAME/PRt_NOM LASTNAME/NOM
rr-B
I
STREETNO/N° RUE STREETNAME/RUE
C31
CiTY/VILLE
Z I
<i
kkll
Z_
I
m,
DIDYOUPURCHASEASERVICECONTRACTFORTHISAPPLIANCE?
AVEZ-VOUSACHETEUNCONTRATDESERVICEPOURCETAPPAREIL?
ZI
NAMEOF SELLINGDEALER/ NOMDU MARCHAND
I
I--B
INSTALLATIONDATE/ DATEDIINSTALLA]ION/
Y/A M D/J CORRESPONDENCE [] ENGLISH
[] Ido notwishtoreceiveanypromotionaloffers_egardingthisproduct.
D Jenedesirepasrecevoird'offrespromotionnellesconcemantceproduit.
CORRESPONDANCE [] FRANOAIS
J
[,oo
VeuiUezenregi_ervotreproduitafindenouspermei_ede
communiqueravecvoussijamaisunavisdes_curit6concemant
ceproduit_¢ait_misetdecommuniquerfacibmentavecvousen
vertudevol_egarar_e,silebesoinsenfairsentir.
P.O.BOX1788,MISSISSAUGA
ONTARIO,L4Y461
PROVINCE POSTALCODE/POSTAL
YES/OUI[]
NO/NOND
MODEL/MOD_:LE
SERIAL/Sl_RIE
IFYES/SIOUhEXPIRATION
Y/A M D/J
APT.NO/APP./RR#
14
GEAir Conditioner--One YearLimited Warranty.motc,stome i,theU.S.A.)
Staple your receipt here.
Proof of the original purchase date
is neededto make a warranty claim.
We Will Replace:
One Year
Fromthedateofthe
originalpurchase
Replacement unitfbr "tinyproduct which fidls due [o a defect in materials or workmanship°
The rephcement unit is warranted for the remainder of your product's original one-year
warranty period. The replacement unit may either be a new unit or a refurbished unit.
Properly pack your unit. We recommend using
the original carton and packing materials.
Return the product to the retail location where
it was purchased.
Locate your original sales receipt and make a note
of your model and serial number.
Call GE at 1.866.907.1655 to initiate the product
replacement process.
._You will be asked to provide your name, address,
date of purchase, model and serial number.
GE will arrange for a carton to be sent to your home
to recover the product.
Customer instruction. This owner's manual provides
information regarding operating instructions and
user controls.
Improper installation. If you have an installation problem,
or if the air conditioner is of improper cooling capacity
for the intended use, contact your dealer or installer.
You are responsible for providing adequate electrical
connecting facilities.
Failure of the product resulting from modifications to
the product or due to unreasonable use including failure
to provide reasonable and necessary maintenance.
Include in the package a copy of the sales receipt or other
evidence of date of original purchase. Also print your
name and address and a description of the defect.
You must return the product (postage pre-pald by GE)
to GE's recovery center before a replacement unit will be
provided. Please include a description of the defect.
You should receive your replacement product within
7 to 10 business days after your unit is received.
If you experience any problems or delays after initiating
the replacement process, please call 1.256.796.6610 for
assistance.
Replacement of house fuses or resetting of circuit
breakers.
Failure due to corrosion on models not corrosinn-
protected.
Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
Incidental or consequential damage caused by possible
defects with this air conditioner.
Damage caused after delivery.
EXCLUSIONOF IMPLIED WARRANTIES--Your sole and exclusive remedy is product replacement as provided
in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or
fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA.
Some states do not aflow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. Toknow what your
legal rights are, consult your local or state consumer affairs office or your state's Attorney General
Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties, whether
express, oral or statutory which extend beyond the description on the face hereof, including specificafly the
impfied warranties of merchantability or fitness for a particular purpose.
Warrantor: General Electric Company. Louisville, KY 40225 75