GE AKV05 Owner’s Manual & Installation Instructions

<![if ! IE]>

<![endif]>AIR CONDITIONER

<![if ! IE]>

<![endif]>Room

 

SAFETY INFORMATION

3

 

 

 

 

OWNER’S MANUAL

 

 

 

 

USING THE AIR CONDITIONER

 

AND INSTALLATION

 

Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

INSTRUCTIONS

 

CARE AND CLEANING

 

AKV05

 

Air Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

 

 

Outdoor Coils . . . . . . . . . . . . . . . . . . . . . . . . .

6

 

INSTALLATION

INSTRUCTIONS . . . . . . . . . . . . . . . . . . .7

TROUBLESHOOTING TIPS. . . . . . 11

Normal Operating Sounds . . . . . . . . . . . . . 12

LIMITED WARRANTY . . . . . . . . . . . 13

CONSUMER SUPPORT . . . . . . . . . . 14

Write the model and serial numbers here:

Model #_________________

Serial # _________________

Find these numbers on a label on the side of the air conditioner.

GE is a trademark of the General Electric Company. Manufactured under trademark license.

49-5000436 Rev. 0 09-19 GEA

THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.

Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.

We take pride in the craftsmanship, innovation and design that goes into every GE Appliances product, and we think you will too. Among other things, registration of your appliance ensures that we can deliver important product information and warranty details when you need them.

Register your GE appliance now online. Helpful websites and phone numbers are available in the Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration card included in the packing material.

2

 

49-5000436 Rev. 0

 

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

Ŷ 8VH WKLV DSSOLDQFH RQO\ IRU LWV LQWHQGHG SXUSRVH DV described in this Owner’s Manual.

Ŷ This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.

Ŷ Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.

Ŷ Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

Ŷ Turn the unit OFF and unplug your air conditioner before cleaning.

Ŷ For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

Ŷ If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.

 

 

 

 

Risk of Fire or Explosion. This unit contains flammable refrigerant.

 

 

 

WARNING

 

 

 

 

Additional safety precautions must be followed.

Ŷ 'R QRW XVH PHDQV WR DFFHOHUDWH WKH GHIURVWLQJ SURFHVV

Ŷ Do not drill holes in the unit.

or to clean, other than those recommended by the

Ŷ Maintenance, cleaning, and service should only be

manufacturer.

 

 

performed by technicians properly trained and qualified

 

 

 

 

 

Ŷ The appliance shall be stored in a room without

in the use of flammable refrigerants.

continuously operating ignition sources (for example:

Ŷ GE Appliances does not support any servicing of the

open flames, an operating gas appliance or an

air conditioner.

operating electric heater.

 

 

Ŷ Dispose of air conditioner in accordance with Federal

Ŷ Do not pierce or burn refrigerant tubing. Be aware that

refrigerants may not contain an odor.

and Local Regulations. Flammable refrigerants require

special disposal procedures. Contact your local

 

 

 

 

 

Ŷ Keep ventilation openings clear of obstruction.

authorities for the environmentally safe disposal of your

Ŷ When handling, installing, and operating the appliance,

air conditioner.

 

care should be taken to avoid damage to the refrigerant tubing.

<![if ! IE]>

<![endif]>INFORMATION SAFETY

READ AND SAVE THESE INSTRUCTIONS

49-5000436 Rev. 0

3

<![if ! IE]>

<![endif]>SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

WARNING USE OF EXTENSION CORDS

RISK OF FIRE. Could cause serious injury or death.

Ŷ '2 127 XVH VXUJH SURWHFWRUV RU PXOWL RXWOHW DGDSWRUV

Ŷ '2 127 XVH DQ H[WHQVLRQ FRUG ZLWK WKLV :LQGRZ $LU

with this Window Air Conditioner.

 

Conditioner.

 

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

DO NOT use an adapter plug with this appliance.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

For appliance recycling information please visit www.geappliances.com/recycling.

READ AND SAVE THESE INSTRUCTIONS

4

49-5000436 Rev. 0

Controls

Features and appearance will vary.

TEMPERATURE CONTROL

Mode Control

High Cool and Low Cool provide cooling with different fan speeds.

Fan settings provide air circulation and filtering without cooling.

NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least

3 minutes before switching back to a cool setting.

Cooling Descriptions

For Normal Cooling—Select High Cool or Low Cool

ZLWK WKH 7(03(5$785( FRQWURO DW PLGSRLQW

For Maximum Cooling—Select High Cool with the

7(03(5$785( FRQWURO DW WKH KLJKHVW QXPEHU DYDLODEOH on your knob.

For Quieter and Nighttime Cooling—Select Low Cool

ZLWK WKH 7(03(5$785( FRQWURO DW PLGSRLQW

TEMP Control

The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

Wait 3 Min

ĞĨŽƌĞ ZĞƐƚĂƌƟŶŐ

MODE CONTROL

Do Not Operate in Freezing Outdoor Conditions

This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.

Air Direction

8VH WKH OHYHU WR DGMXVW WKH DLU GLUHFWLRQ OHIW DQG ULJKW only.

<![if ! IE]>

<![endif]>CONDITIONER AIR THE USING

49-5000436 Rev. 0

5

<![if ! IE]>

<![endif]>CARE AND CLEANING

Care and Cleaning

Grille and Case

Turn the air conditioner off and remove the plug from the

To clean, use water and a mild detergent. Do not use

wall outlet before cleaning.

bleach or abrasives.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove:

Pull the tab on the right side of the unit until the filter is out.

To remove:

Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Your filter is also dishwasher safe, top rack and straight placement in dishwasher is recommended.

CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

Tab

Tab

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

6

49-5000436 Rev. 0

Installation Instructions

Questions? Call GE Appliances at 800.GE.CARES (800.432.2737) or visit our Website at: GEAppliances.com.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT Save these instructions for local inspector’s use.

IMPORTANT Observe all governing codes and ordinances.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Skill level – Installation of this appliance requires basic mechanical skills.

Completion time – Approximately 1 hour

We recommend that two people install this product.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

<RX 0867 XVH DOO VXSSOLHG SDUWV DQG XVH SURSHU installation procedures as described in these instructions when installing this air conditioner.

ELECTRICAL REQUIREMENTS

Some models require a 115/120-volt AC, 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

CAUTION

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

TOOLS YOU WILL NEED

 

Phillips head screwdriver

 

Flat-blade screwdriver

Pencil

Ruler or tape measure

Level

Scissors or knife

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

<![if ! IE]>

<![endif]>INSTRUCTIONS INSTALLATION

49-5000436 Rev. 0

7

GE AKV05 Owner’s Manual & Installation Instructions
<![if ! IE]>

<![endif]>INSTRUCTIONS

Installation Instructions

 

 

 

PARTS INCLUDED

 

 

 

 

 

(Appearance may vary)

 

 

 

 

 

 

 

 

Window

 

 

 

Top mounting rail and

Foam top window

sill and sash seal

 

 

gasket

 

 

 

 

 

seal strip

 

 

 

<![if ! IE]>

<![endif]>INSTALLATION

 

 

 

 

 

 

 

Left

 

 

 

 

 

 

accordion

 

Right

 

 

 

 

panel

 

 

 

 

 

 

 

accordion

 

 

 

 

 

 

panel

 

 

Air

 

 

 

 

 

 

conditioner

 

 

 

 

 

 

Type A (4)

Type B (7)

Lock frame (2)

Lock frame (2)

Sash lock (1)

 

 

3/8” screws

3/4” or 1/2” screws

For wooden windows

For Vinyl-Clad windows

 

 

 

 

 

 

(on some models)

 

 

 

8

 

 

 

49-5000436

Rev. 0

Installation Instructions

1.WINDOW REQUIREMENTS

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

Follow the dimensions in the table and illustration for your model.

13” min

23” - 36”

(With accordion panels)

2. STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will

NHHS LW IURP GUDLQLQJ SURSHUO\ 7R DGMXVW IRU WKLV attach a piece of wood to the sill.

WOOD PIECES

:,'7+ Ǝ

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place

D SLHFH RI ZRRG RQ WKH VLOO WR PDNH LW Ǝ KLJKHU than the top of the storm window frame or the vinyl frame.

Attach securely with nails or screws provided by the installer.

Ǝ KLJKHU than storm window

frame

Storm window frame

Ǝ KLJKHU than vinyl frame

(on some windows)

Wood

Sill

Vinyl frame

3.PREPARE THE AIR CONDITIONER

A.Install the top mounting rail with 4 Type A screws from the outside of the case.

Top mounting rail

Bottom

mounting rail

B.Hold the accordion panel in one hand and gently pull back to free the open end.

C.Slide the free end of the accordion panel into the side panel rails. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.

NOTE: There is a right and a left accordion panel. Be sure to use the proper panel for each side.

Top mounting rail

Bottom

mounting rail

D.Slide the left and right accordion panels into the top and bottom mounting rails.

<![if ! IE]>

<![endif]>INSTRUCTIONS INSTALLATION

49-5000436 Rev. 0

9

Loading...
+ 19 hidden pages