GE AKL05, AKN05, AKQ05, AKS05, AKV05 Owner’s Manual & Installation Instructions

...
AKL05 AKN05 AKQ05
AKS05 AKV05 AKL06 AKN06 AKQ06 AKV06
Safety Instructions . . . . . . . .2, 3

Operating Instructions

Control Knob Models . . . . . .6, 7
Touch Pad Models . . . . . . . . .4, 5
Air Filter . . . . . . . . . . . . . . . . . .8
Grille and Case . . . . . . . . . . . . .8
Outdoor Coils . . . . . . . . . . . . . .8
Installation Instructions . .9–17
Troubleshooting Tips . . .19, 20
Normal Operating Sounds . . .20

Consumer Support

Consumer Support . . . . . . . . .24
Product Registration . . . . .21, 22
Warranty . . . . . . . . . . . . . . . . .23
49-7452-1 12-02 JR
Owner’s Manual and
Installation Instructions
Write the model and serial numbers here:
Model # __________________________
Serial # __________________________
Find these numbers on a label on the side of the air conditioner.
Air Conditioners
Room
www.GEAppliances.com
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
Use this appliance only for its intended
purpose as described in this Owner’s Manual.
This air conditioner must be properly
installed in accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by
pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Repair or replace immediately all electric
service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
Turn the mode control to OFF and unplug
your air conditioner before making any repairs or cleaning.
NOTE: We strongly recommend that any
servicing be performed by a qualified individual.
For your safety…do not store or use
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
SAFETY PRECAUTIONS
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
HOW TO CONNECT ELECTRICITY
Consumer Support

Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions

2
3
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
WARNING!
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the 230/208 volt models.
USE OF EXTENSION CORDS—115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.
USE OF ADAPTER PLUGS—115-Volt models only
www.GEAppliances.com
SAVE THESE INSTRUCTIONS
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
4
About the controls on the air conditioner—models with touch pads.
Features and appearance will vary.
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
To ensure proper operation, aim the remote
control at the signal receiver on the air conditioner.
The remote control signal has a range of
up to 21 feet.
Make sure nothing is between the air conditioner
and the remote control that could block the signal.
Make sure batteries are fresh and installed
correctly as indicated on the remote control.
Air Conditioner Controls
Controls
ON/OFF Pad
Turns air conditioner on and off.
MODE
Use to set the air conditioner to COOL or FAN mode.
Increase /Decrease Pads
Use to set temperature when in COOL mode.
FAN Pad
Use to set the fan speed to LOW, MED or HIGH.
TIMER Pad
ON—When the air conditioner is off,
it can be set to automatically turn on in 1 to 12 hours at its previous setting. Each touch will set the timer in hours.
OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 12 hours. Each touch will set the timer in hours.
To cancel the timer, press the TIMER pad until the display time disappears.
NOTE: All timer settings are automatically cancelled if the unit is turned on or off after setting the timer.
Display
Shows the room temperature, set temperature or the time remaining on the timer. After setting the controls, the display will change to show the room temperature.
To recall the set temperature to the display, press the Increase / Decrease pad once.
To recall the time remaining on the timer, if it was set, press the TIMER pad once.
Display Codes E1—Automatic filter clean reminder.
Turn the air conditioner OFF and unplug it. NOTE: The air conditioner must be unplugged
for the automatic filter clean timer to reset. Clean the filter. See the Care and Cleaning section. After cleaning, replace the filter and plug the air conditioner back in.
Er—Room temperature sensor failure. Call for service.
Remote Control Signal Receiver
Remote Control
Remote Control
Cool on
Fan on
High fan on
Medium fan on
Low fan on
5
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
www.GEAppliances.com
When the air conditioner is turned on, it will automatically start in the setting last used, except the timer will be cancelled if it was set.
Lights in the display or beside the touch pads on the air conditioner control panel indicate the selected settings.
Use the COOL mode with HIGH, MED or LOW fan for cooling. Use the Increase / Decrease pads to set the desired temperature between 60°F and 90°F in 2°F increments (or between 16°C and 31°C in 1°C increments if the control has been set to use Celsius).
A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the COOL mode and HIGH or MED fan with a middle set temperature.
For Maximum Cooling—Select the COOL mode and HIGH fan with a lower set temperature.
For Quieter & Nighttime Cooling—Select the COOL mode and LOW fan with a middle set
temperature.
NOTE: If you switch from a COOL setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a COOL setting.
COOL Mode
Use the FAN at HIGH, MED or LOW to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.
Your control is set to use and display Fahrenheit temperature selections, but you may change it to use and display Celsius selections.
Press and hold the Increase / Decrease ▼ pads at the same time to switch to ˚C or ˚F as desired.
FAN Mode Fahrenheit or Celsius
The vent control is located on the inside of the air louvers at the bottom of the vent.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at
OPEN, some inside air is exhausted outside.
Vent Control
Up and Down
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
Side-to-Side
The side-to-side air direction is adjusted by moving the air direction lever to the left or right.
Air Direction
To open the vent.
To close the vent.
Vent control lever
Vent control lever
Air direction lever
6
About the controls on the air conditioner—models with control knobs.
Features and appearance will vary.
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
Controls
Mode Controls
HIGH COOL, MED COOL and LOW COOL provide
cooling with different fan speeds.
COOL provides cooling with a fixed fan speed.
LOW FAN, HIGH FAN or FAN provides air
circulation and filtering without cooling.
NOTE: If you move the switch from a cool setting to OFF or to a fan setting, wait at least 3 minutes before
switching back to a cool setting.
Cooling Descriptions
For Normal Cooling—Select HIGH COOL or MED COOL with the temp control at midpoint.
For Maximum Cooling—Select HIGH COOL with
the temp control at the highest number available on your knob.
For Quieter and Nighttime Cooling—Select LOW COOL with the temp control at midpoint.
Temp Controls (on some models)
The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
TEMP CONTROL (on some models)
MODE CONTROLS
Your model will have one of the above type controls.
OFF
LOW
FAN
LOW
COOL
HIGH
FAN
HIGH COOL
MED
COOL
OFF
FANCOOL
7
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
www.GEAppliances.com
Additional controls and important information.
The vent control is located on the inside of the air louvers at the bottom of the vent.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at
OPEN, some inside air is exhausted outside.
Vent Control
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
Air Direction—Up and Down
The side-to-side air direction is adjusted by moving the air direction lever to the left or right.
Air Direction—Side-to-Side (on some models)
To open the vent. To close the vent.
Vent control lever
Vent control lever
Air direction lever
8
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
Care and cleaning of the air conditioner.
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.

Grille and Case

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned, a service available through your GE service outlet.

Outdoor Coils

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
E1 in the display (on models with touch pads) is an automatic filter clean reminder. Turn the air conditioner OFF and unplug it.
NOTE: The air conditioner must be unplugged for the automatic filter clean timer to reset.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.
NOTE: DO NOT rinse, or put the filter in an automatic dishwasher.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will clog it and reduce performance.
To remove:
Pull to unlatch the lower corners of the inlet grille and lift it up and off.
Using the tab, pull up slightly on the filter to release it and pull it down to remove.
2
1

Air Filter

Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions

9
Preparing to install the air conditioner.
Read these instructions completely and carefully.
NOTE TO INSTALLER: Leave these instructions with
the air conditioner after installation is completed.
NOTE TO CONSUMER: Keep this Owner’s Manual and Installation Instructions for future use.
IMPORTANT NOTES:
For personal safety, this air conditioner must be properly grounded.
It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.
Follow National Electrical Codes (NEC) and/or local codes and ordinances.
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems
consult a qualified electrician.
Before You Begin
Some models require 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Electrical Requirements
Phillips-head screwdriver
Adjustable wrench
Ruler or tape measure
Drill
Scissors or knife
Pencil
Level
Tools You Will Need
Type A (7)
Support bracket (2)
Right accordion
panel frame
Foam top
window gasket
Window
sash seal
Left accordion
panel frame
Type B (11)
Accordion panel
clamp (2)
10
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
Window installation instructions.
Parts Included
Leveling bolt (2)
Top mounting rail
seal strip
Bottom
mounting rail
Air conditioner case
To p
mounting
rail
Window locking
bracket
Locking bar (2)
Type C (4)
Nut (2)
Left accordion
panel
Right accordion
panel
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
11
Read completely, then follow step-by-step.
Window Requirements
These instructions are for a standard double-
hung window. You will need to modify them for other types of windows.
The air conditioner can be installed without
the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
All supporting parts must be secured to firm
wood, masonry or metal.
The electrical outlet must be within reach of the
power cord.
1
14min.
22to 351⁄2
(With accordion panels)
171⁄2min.
(Without accordion panels)
Storm Window Requirements
A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.
WOOD PIECES
WIDTH: 2
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2higher than the top of the storm window frame.
Attach securely with nails or screws provided by the installer.
2
1/2higher than frame
Storm window frame
Wood
Stool
12
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
Remove the Air Conditioner From the Case
Remove the screw from each side of the case. Keep them in a safe location.
Pull to unlatch the lower corners of the inlet grille and lift it up and off.
Using the tab, pull up slightly on the filter to release it and pull it down to remove.
Remove the three grille frame screws.
Grasp the lower corners of the grill frame while pressing in on the case sides with your finger tips. Pull out to release and lift it up.
NOTE: Do not pull the bottom edge toward you more than 3 ″ or you may damage the tabs of the grille.
Remove the screw securing the ground wire to the left side of the face of the unit.
Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case.
G
F
E
D
C
B
A
3
Window installation instructions.
Grille
frame
screws
Ground wire
Screw
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
13
Remove the Shipping Pad
Remove and discard the shipping pad next to the compressor.
4
Install the Mounting Rails onto the Case
Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail.
Attach the top mounting rail onto the top of the case with 5 Type A screws.
Attach the bottom mounting rail to the bottom of the case from the inside, using 2 Type A screws in the back holes of the bottom rail sides.
C
BA
5
Remove and discard shipping pad
Type A screws
Type A screws
Type A
screws
Type A screw
14
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
Install the Side Accordion Panels
Insert the notch on the wider side of one shutter into the groove on the left front side of the case.
Slide the shutter all the way down into the groove.
Slide the left accordion panel into the top and bottom mounting rails.
Pull the shutter all the way out until the notch on the outside edge of the shutter is visible through the hole in the top corner of the frame. Insert the notch on the shutter into the groove on the locking bar and slide the bar all the way down to secure the shutter.
Repeat steps A–C for the right side accordion panel.
D
C
BA
6
Window installation instructions.
Prepare the Window
Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash.
7
Window sash seal
Shutter
Notch
Locking bar
Notch
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
15
Install the Case in the Window
Carefully position the case in the window so that the bottom mounting rail is nested against the window stool.
Center the case and lower the window behind the top mounting rail.
Secure the bottom mounting rail of the case to the window stool using 4 Type B screws.
Loosely thread a leveling bolt into a support bracket.
Position the support brackets near the outermost point on the sill. From inside the case, attach the support bracket to the case bottom flange using 2 Type C screws.
Repeat steps D and E to install the second support on the other side of the case.
Adjust the leveling bolts against the sill so that the supports had a slight tilt to the outside. Use a level; about 1/2 bubble will be the correct slant to the outside. After leveling is done, tighten the leveling bolt nut.
NOTE: Use a steel washer between the leveling bolts and the sill if the sill is weak.
Extend the left and right accordion panels to the vertical window sashes. Drill 1/8″ pilot holes and attach the top corners with 2 Type B screws. Use an accordion panel clamp on each lower corner to trap the panels. Drill 1/8pilot holes and attach the panel clamps with 2 Type B screws.
NOTE: Seal any openings around the case or accordion panels with sealer or foam gaskets.
H
G
F
E
D
C
B
A
8
1/2 bubble slant to outside
Leveling bolt
Type C screws
Support bracket
Type B screws
Support bracket
Leveling bolt
Type B screw
Type B screw
Panel clamp and Type B screw
Top mounting rail
Panel clamp and Type B screw
Loading...
+ 33 hidden pages