GE AKH08, AKH12 Owner’s Manual & Installation Instructions

GEAppliances.com
Safety Instructions . . . . . . . . . . . . .2, 3
Operating Instructions
Controls . . . . . . . . . . . . . . . . . . . . . .4–6
Care and Cleaning
Air Filter . . . . . . . . . . . . . . . . . . . . . . . .6
Outdoor Coils . . . . . . . . . . . . . . . . . . . .6
Room
Installation Instructions . . . . . . .7–10
Troubleshooting Tips . . . . . . . . . . .11
Normal Operating Sounds . . . . . . . .11
Consumer Support . . . . . . .Back Cover
Ownership Registration for
Customers in Canada only . . . . .13, 14
Warranty for Customers
in Canada . . . . . . . . . . . . . . . . . . . . . .16
Warranty for Customers
in the U.S.A. . . . . . . . . . . . . . . . . . . . .15
Owner’s Manual and
Installation Instructions
AKH08* AKH12*
Climatiseur
Manuel d’utilisation et
instructions d’installation
La section française commence à la page 17
Acondicionador
*ENERGY STA R®labeled product
As an ENERGY STAR®partner, GE has determined that this product meets
NERGY STAR
the E energy efficiency.
Write the model and serial numbers here:
Model # __________________________
Serial # __________________________
Find these numbers on a label on the side of the air conditioner.
Air Conditioners
In Canada, contact us at: www.GEAppliances.ca
®
guidelines for
de aire
Manual del propietario
y instrucciones de
instalación
La sección en español empieza en la página 33
49-7631 01-10 JR
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
Safety Instructions
SAFETY PRECAUTIONS
Use this appliance only for its intended
purpose as described in this Owner’s Manual.
This air conditioner must be properly
Operating
Instructions
Care and Cleaning
installed in accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Replace immediately all electric service
cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
Turn the unit OFF and unplug your air
conditioner before cleaning.
GE does not support any servicing of the air
conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
For your safety…do not store or use
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
If the receptacle does not match the plug,
the receptacle must be changed out by a qualified electrician.
These R410A air conditioning systems
require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only.
Installation
Instructions
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric
Troubleshooting TipsConsumer Support
2
shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
WARNING!
USE OF EXTENSION CORDS—115-Volt models only
Safety Instructions
GEAppliances.com
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14-gauge, 3-wire grounding-type appliance extension cord having a grounding-type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the 230/208 volt models.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
Instructions
Operating
Care and Cleaning
Instructions
Installation
Consumer SupportTroubleshooting Tips
3
About the controls on the air conditioner.
Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Light indicates the unit is in temperature or delay time Set mode.
Safety Instructions
Light indicates the delay timer is set.
Operating
Instructions
(on some models)
NOTE: The display always shows the room temperature except when setting the Set temperature or the Delay timer.
Delay timer and temperature set
Decrease/Increase
Delay 1–24hr
Mode select
Unit power on/off Auto Fan on/off and
Decrease/Increase
Air Conditioner Controls
Remote Control
Controls
Power Pad
Care and Cleaning
Turns air conditioner on and off. When turned on, the display will show the room temperature.
Display
Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.
Installation
Instructions
NOTE: The display will change to show the
room temperature after settings have been made. To recall the Set temperature, press the
Temp Increase or Decrease pads.
Temp Increase / Decrease Pads
Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while
setting.
Delay Timer Increase / Decrease Pads
Each touch of the Increase / Decrease pads on the unit or on the remote control will
Troubleshooting TipsConsumer Support
set the delay time when using the Delay 1–24hr timer. The Set light will turn on while setting.
Fan Speed Pad
Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the Fan button to set the fan speeds to Low, Med, High or Auto.
Mode Pad
Use to set the air conditioner to Cool, Energy Saver or Fan mode.
Delay Pads
Delay ON—When the air conditioner is off, it
can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.
Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.
How to set:
Press the Delay 1–24hr pad on the unit or on the remote control. Each touch of the Increase / Decrease ▼ pads on the unit or on the remote control will set the timer in 1/2-hour intervals until the time reaches 10 hours; then it will increase in 1-hour intervals. The Set light will turn on while setting.
To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or on the remote control. Use the Increase / Decrease ▼ pads on the unit or on the remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.
4
Clean Filter
The “Clean Filter” light will come on to tell you it is time to change your filter.
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.
Safety Instructions
GEAppliances.com
Remote Control
To ensure proper operation, aim the remote
control at the signal receiver on the air conditioner.
The remote control signal has a range of
up to 20 feet.
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase / Decrease pads to set the desired temperature
between 62°F and 86°F in 1°F increments. An electronic thermostat is used to maintain the
room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.
Energy Saver Mode
Controls the fan. ON—The fan will cycle on and off with the
compressor. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan may continue to run
for a short time after the compressor cycles off.
Make sure nothing is between the air conditioner
and the remote control that could block the signal.
Make sure batteries are fresh and installed
correctly as indicated on the remote control.
Cooling Descriptions
For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.
For Quieter and Nighttime Cooling—Select the Cool mode and Low fan with a middle set
temperature.
OFF—The fan runs all the time, while the compressor cycles on and off.
Instructions
Operating
Care and Cleaning
Instructions
Installation
Fan Mode
Use the Fan Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.
Auto Fan Speed
Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.
Power Outage Recovery Feature
In the case of a power outage or interruption, the unit will automatically restart in the settings last used after the power is restored. If the Delay 1–24hr
NOTE: Auto Fan Speed is available in the Fan Mode.
NOTE: Auto Fan Speed is available in the Fan Mode.
Consumer SupportTroubleshooting Tips
feature was set, it will resume countdown. You may need to set a new time if desired.
5
About the controls on the air conditioner.
Additional important information.
Air Direction
Use the lever to adjust the air direction left and right only.
Safety Instructions
Fresh Air Vent Control (on some models)
The Fresh Air Vent Control allows you to let fresh
Operating
Instructions
air into the room.
To open the vent, pull the tab out to allow fresh air to circulate into the room.
To close the vent, push the tab in.
Vent open
Vent closed
Care and cleaning of the air conditioner.
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Care and Cleaning
Air Filter
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.
Installation
Instructions
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
Tab
Tab
CAUTION:DO NOT operate the air conditioner
without a filter because dirt and lint will clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.
Troubleshooting TipsConsumer Support
How to Insert the Batteries in the Remote Control
Remove the battery cover by sliding it
1
according to the arrow direction. Insert new batteries, making sure that the (+)
2
and (–) of battery are installed correctly. Reattach the cover by sliding it back
3
into position.
6
NOTES:
Use 2 “AAA” (1.5 volt) alkaline batteries. Do not
use rechargeable batteries.
Remove the batteries from the remote control if
the system is not going to be used for a long time.
Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc.) batteries.
Installation
Air Conditioner
Instructions
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these
instructions for future reference.
Skill level – Installation of this appliance
requires basic mechanical skills.
Completion time – Approximately 1 hour
We recommend that two people insta
his product.
t
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
ll
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
TOOLS YOU WILL NEED
Phillips head screwdriver
Flat-blade screwdriver
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt AC, 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt AC, protected with a time-delay fuse or circuit breaker. These models should be installe on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Ruler or tape measurePencil
Level
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a
d
periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
7
Scissors or knife
Installation Instructions
PARTS INCLUDED
(Appearance may vary)
Top mounting rail
Air
conditioner
Window
sash seal
Foam top
window gasket
Right
accordion
panel
Left
accordion
panel
3/8" Type A (4) 3/4" Type B (6)
If top rail is not
already attached
Window locking
bracket (1)
8
Frame locking
bracket (2)
Installation Instructions
1
WINDOW REQUIREMENTS
These instructions are for a standard double­hung window. You will need to modify them for other types of windows.
The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
All supporting parts must be secured to firm wood, masonry or metal.
The electrical outlet must be within reach of the power cord.
Follow the dimensions in the table and illustration for your model.
Models AB
AKH08LN 13 1/2min. 22 3/16–39 AKH12AN 16min. 23–38 1/8
A
3
PREPARE THE AIR CONDITIONER
If not already attached, install the top
A
mounting rail with 4 Type A screws from the outside of the case.
Top mounting rail
Bottom mounting rail
Hold the accordion
B
panel in one hand and gently pull back to free the open end.
B
(With accordion panels)
2
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.
WOOD PIECES WIDTH: 2 LENGTH: Long enough to fit inside the
window frame. THICKNESS: To determine the thickness, place
a piece of wood on the sill to make it 1/2 higher than the top of the storm window frame or the vinyl frame.
Attach securely with nails or screws provided by the installer.
1/2higher than storm window frame
Storm window frame
1/2higher than vinyl frame (on some windows)
Sill
Vinyl frame
Wood
C
Slide the free end of the accordion panel into the side panel rails. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
NOTE:There is a right and a left accordion panel. Be sure to use the proper panel for
h s
eac
D
Slide the left and right accordion panels
ide.
into the top and bottom mounting rails.
Top left
Bottom mounting rail
Top mounting rail
Top right
9
Installation Instructions
4
PREPARE THE WINDOW
Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.
5
INSTALL THE AIR CONDITIONER IN THE WINDOW
A
Place the air conditioner on the sill with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the outside. Use a level; about a 1/3 bubble will be the correct case slant to the outside.
3 Screws
6
INSTALL SUPPORT BRACKET AND FOAM TOP WINDOW GASKET
A
B
C
CAUTION:
To prevent broken glass or damage to windows, on vinyl or other similarly constructed windows, attach the window locking bracket to the window side jamb.
Attach the window locking bracket with one Type B screw.
Cut the foam top window gasket to the window width.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room. NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
Vinyl
Wood
2 Frame locking brackets
B
Extend the left and right accordion panels to the vertical window sashes and attach 3 Type B screws through the holes in the upper panels, as appropria
nstall the frame locking brackets between
I
C
the bottom of the accordion panel and the window sill. Attach with 2 Type B screws. NOTE:To prevent the window sill from splitting, drive the pilot holes before driving the screws.
te.
10
Troubleshooting Tips. GEAppliances.com
Problem Possible Causes What To Do
Air conditioner The air conditioner Make sure the air conditioner plug is pushed does not start is unplugged. completely into the outlet.
The fuse is blown/circuit Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
Power failure. The unit will automatically restart in the settings last
used after the power is restored.
There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.
The current interrupter Press the RESET button located on the power cord plug. device is tripped.
Air conditioner does Airflow is restricted. Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.
The temp control may In the Cool mode, press the Decrease pad. not be set correctly.
If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Safety Instructions
Instructions
Operating
Care and Cleaning
The air filter is dirty. • Clean the filter at least every 30 days.
See the Care and Cleaning section.
The room may have been hot. • When the air conditioner is first turned on, you need
to allow time for the room to cool down.
Cold air is escaping. Check for open furnace registers and cold air returns.
Cooling coils have iced up. See “Air conditioner freezing up” below.
Air conditioner Ice blocks the air flow • Set the controls at High Fan or High Cool and set the freezing up and stops the air conditioner thermostat to a higher temperature.
from cooling the room.
The remote control The batteries are inserted Check the position of the batteries. They should be is not working incorrectly. inserted in the opposite (+) and (–) direction.
The batteries may be dead. Replace the batteries.
Water drips outside Hot, humid weather. This is normal.
Water drips indoors The air conditioner is not For proper water disposal, make sure the air conditioner
tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture removed from air This is normal for a short period in areas with little base pan and drains into base pan. humidity; normal for a longer period in very humid areas.
Instructions
Installation
Normal Operating Sounds
You may hear a pinging noise caused by water
being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
You may hear the thermostat click when the
compressor cycles on and off.
Water will collect in the base pan during
high humidity or on rainy days. The water may overflow and drip from the outdoor side
of the unit.
The fan may run even when the compressor
does not.
Consumer SupportTroubleshooting Tips
11
Notes.
Safety Instructions
Operating
Instructions
Care and Cleaning
Installation
Instructions
Troubleshooting TipsConsumer Support
12
Please place in envelope and mail to: Veuillez mettre dans une enveloppe et envoyez à :
OWNERSHIP REGISTRATION P.O. BOX 1780 MISSISSAUGA, ONTARIO L4Y 4G1
(FOR CANADIAN CONSUMERS ONLY)
13
14
GE Air Conditioner—One-Year Limited Warranty. (For customers in the U.S.A.)
Staple your receipt here. Proof of the original purchase date is needed to make a warranty claim.
For The Period Of: We Will Replace:
One Year Replacement unit for any product which fails due to a defect in materials or workmanship.
From the date of the The replacement unit is warranted for the remainder of your product’s original one-year original purchase warranty period.
In Order to Make a Warranty Claim:
Safety Instructions
Instructions
Operating
Properly pack your unit. We recommend using the
original carton and packing materials.
Return the product to the retail location where it
was purchased.
Include in the package a copy of the sales receipt or other
evidence of date of original purchase. Also print your name and address and a description of the defect.
What Is Not Covered:
Customer instruction. This owner’s manual provides
information regarding operating instructions and user controls.
Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner is of improper cooling capacity, contact your dealer or installer. You are responsible for providing adequate electrical, plumbing and other connecting facilities.
Failure of the product resulting from modifications to
the product or due to unreasonable use, including failure to provide reasonable and necessary maintenance.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product replacement as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
Replacement of house fuses or resetting of circuit
breakers.
Failure due to corrosion on models not corrosion-
protected.
Damage to the product caused by improper power supply
voltage, accident, fire, floods or acts of God.
Incidental or consequential damage caused by possible
defects with this air conditioner.
Damage caused after delivery.
Care and Cleaning
Instructions
Installation
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Exclusion of implie
express, oral or statutory which extend beyond the description on the face hereof, including specifically the implied warranties of merchantability or fitness for a particular purpose.
arranties: Except where prohibited or restricted by law, there are no warranties, whether
d w
Warrantor: General Electric Company. Louisville, KY 40225
Consumer SupportTroubleshooting Tips
15
Loading...
+ 33 hidden pages