GE AJES12DCA Specification

AJES12DCA—GE 230 Volt ”J Series” Window/Wall Mount Heat and Cool Unit with Mechanical Controls
GE Appliances
Specification Created 5/01
26
15-5/8
16-7/8
Wall Case Dimensions (in inches)
230/208V 20 Amp
R
R
Total capacity and E.E.R. ratings are calculated based on the Association of Home Appliance Manufacturers’ standards.
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
Note: When installing slide-out chassis units in through-the-wall applications, keep louvers free. Do not restrict air flow areas.
Specification Created 5/01
GE Appliances
AJES12DCAGE 230 Volt J Series Window/Wall Mount Heat and Cool Unit with Mechanical Controls
Dimensions (in inches)
Installation Information: A finished opening of
26-1/8" x 15-3/4" clear of intrusions is required. Keep clearance of 4" from side walls. Brick veneer or frame walls should have wood studding surrounding case to provide firm anchoring with screws. Case can be fastened directly to brick or block walls with screws sunk in lead expansion shields.
Note: Units should be caulked on all four sides of case to the building exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these wall cases provide protection against outside elements. RAB47–includes wall case, exterior grille and steel closure panels. RAB48–includes wall case, exterior grille, steel closure panel and two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with baked enamel finish. Welded areas are coated with a sealing compound to help resist rust and corrosion. Polymer gasket surrounds opening to assure tight weather seal. Aluminum grille (RAG13) is included. Panels on interior and between case and grille provide weather protection prior to installation of chassis.provide firm anchoring with screws. Case can be fastened directly to brick or block walls with screws sunk in lead expansion shields.
Brick Block and Brick Frame Construction
Fill open cells with mortar or insulation
15-3/4
26-1/8
Lintel
Make frame if desired or caulk between case and siding
15-3/4
26-1/8
Frame Construction
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding (if desired)
Plaster Line
Flexible Mounting Position
R
R
Total capacity and E.E.R. ratings are calculated based on the Association of Home Appliance Manufacturers standards.
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
Specification Created 5/01
GE Appliances
AJES12DCAGE 230 Volt J Series Window/Wall Mount Heat and Cool Unit with Mechanical Controls
Features and Benefits
11,600/11,400 BTUH, 230/208 Volts
9.0/9.0 E.E.R
Electric Resistance Heating: 11,600/9,480 BTHU, 16.0 Amps, 3400/2780 Watts
Mechanical Controls with Variable Setting Thermostat
2 Cooling/2 Heating/2 Fan Only Speeds
Fan Cycle Switch for Reduced Energy Consumption
Slide-Out Chassis
3.2 Dehumidification (pints/hr)
265/230 Airflow (CFM) Roomside Hi/Low
Exhaust for Air Exchange
1290/1265 Watts/5.8/6.3 Amps
Slide-Out Filter for Easy Cleaning
Wall CaseRequired Accessory (RAB46/47/48)
Optional Wall Mount Installation Kit
Plug Type–Perpendicular
Rotary Compressor
Model AJES12DCA