Ge Ahw50lmg1, Ahm30lkg1, Ahm40lkg1, Ahw50llg1, Ahw40llg1 Owner's Manual

...
Safety Instruc_tions ........... 2, 3
gO.COrn
Operating Instruotions
About the Controls
on the Dehumidifier ........... 4
Automatic Deflost .............. 5
Choosing a Location ............ 5
How the Dehumidifier Operates . . .5
Installing the _v\ater Bucket ....... 6
Removing Collected _Aater . ..... 6
V\ater Level ................... 6
Care and Cleaning
Air Filter ..................... 7
Cleaning the Coil .............. 7
Grille and Case ................ 7
*Aater Bucket .................. 7
Consumer Support
Warranty .................... 11
*ENERGY STAR ('_ labeled product
aHw3ou
AHH401_*
ENERGYSTAR
As an ENERGY STAR_ partner, GE has
determined that this product meets the ENERGY STAR_ guidelines fin" energy
efticiency.
Write the model and serial numbers here:
Model # Serial #
You can find them on a label on the back
of the dehumidifier behind the bucket.
3828A20315T 49-7532 11-05JR
iMPORTANTSAFETYiNFORMATiON. READALLiNSTRUCTiONSBEFOREUSING.
WARNING!
For your safetg the information in this manual must be followed to minimize the risk of fire, electric shock or personal injurg
SAFETYPRECAUTIONS
When using this dehumidifier, always follow basic safe_ precautions, including the following:
[] Use this appliance only fbr its intended [] Turn the dehumidifier OFFand unplug it
purpose as described in this Owner's Manual.
[]
Th[_ dehumidifier mttst be properly irLstalled and grounded as described
in this manual before it is ttsed.
[]
Never operate tlfis dehumidifier in an area that is likely to accumulate standing water.
If this condition de_lops, for your safety
disconnect the power supply' before
stopping into the wamr.
[]
Never unplug y'our dehumidifier by pulling on the power cord. Always grip plug firmly and pull straight out flom the receptacle.
[]
Replace immediately all electric service cords that have become flaved or otherwise
damaged. A damaged power supply cord nmst be replaced with a new power supply
cord obtained flom the manufi_cturer and
not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
before making any' repairs or cleaning.
[]
GE does not support any servicing of the dehumidifier. _¢\%strongly recommend that you do not at/erupt to seiMce the dehumidifier yourself.
[]
For your safety, do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
[]
All dehumidifiers con rain refrigerants,
which under federal law must be removed prior to product disposal. If you are g>tting
rid of an old product with refl_igerants, check with the company handling disposal
about what to do.
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
For personal safely, this appliance must be properly grounded.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall
outlet to minimize the possibility of electric
shock hazard flom this appliance.
Hme the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
2
_]lere a 2-piong wall outlet is encounmred, it is your personal responsibility and obligation to have it replaced with a properly gTounded 3-prong wall outlet.
The dehumidifier should always be plugged into its own individual electrical outlet, which has a xoltag> rating matching the rating plato.
This provides the best per%rmance and also piexents oxerloading house wiring circuits,
which could cause a fire hazard flom oxerheated wires.
USEOFEXTENSIONCORDS
ge.com
Because of potential safety hazards under certain conditions, we strongly recommend
against the use of an extension cord.
USEOFADAPTERPLUGS
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
However, if you must use an adapter,
where local codes permit, a temporary
connection may be made to a properly
grounded 9-i)rong wall outlet 1)yuse of
a Ui,-lismd adapter available at most
local hardware stores.
The larger slot in the adapter must be
aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
However, if you must use an extension
cord, it is absolumly necessa_ T that it be
a Ui,-lismd, 14 gauge, 3-wire grounding type appliance extension cord having a
grounding type plug and outlet and that
the electrical rating of the cord be 15 amperes (minimum) and 195 volts.
When disconnecting the power cord fiom
the adapter, always hold the adaptor in place with one hand while pulling the power cord plug with the other hand. If this is not done,
the adaptor ground mrmina] is very likely to break with repeated use.
If the adapter ground terminal 1)reaks,
DO NOT USE the dehumidifier until a proper ground has been established.
Attaching the adapter groundterminal to a waft
outlet cover screw does not ground the appliance
unless the cover screw is metal, not insulated, and
the waft outlet is grounded through the house wiring.
Youshould have the circuit checkedby a qualified electrician to make sure the outlet is properly grounded.
READANDFOLLOWTHISSAFETYINFORMATIONCAREFULLY. SAVETHESEINSTRUCTIONS
About the controls onthedehumidifier.
Bucket
Full Fan
ControlsO POWER Pad
Press to mrn the dehmnidifier on and off,
HUMIDITY CONTROLPads
The lmmidi_' lexel can be set within a range of 35% RH (Relafixe Hmnidity) to 70% RH
(Relatixe Hmnidit)) in 5% increments,
For drier ai_, press the pad and set to a lower percent xflue (%).
For damper ai_; press the pad and set
to a higher, I)ercent.... xal ue (%).
When vou first use the dehumidifier; set the hmniditv control to 45% or 50%. Mlow at
least 24 hem5 fin" the dehumidifier to achieve the humidity level. If you still have
damper air than desired, set the humidity level to a lower setting.
High
Humidity
Control
O FAN SPEEDPad
Controls the tim speed,
Press to set to HIGH or LOWfim speed.
Set the tim control to HIGHfin" maMm um
moisture remowfl. When the hmniditv has been reduced and quiet operation is
preferred, set the tim control to LOW,
O HUMIDITY LEVELDISPLAY
Displa)s percent hmnidit) lexel. Its accuracy is (+/- 5%).
O BUCKETFULLLED
Indicates presence of bucket and its fill lexel.
OtherFeatures
BUCKETFULLLight
Glows when the bucket is ready to be emptied, or when the bucket is removed or not replaced
in the proper position.
Auto Shut Off
The XAater I,e\'el Control Switch shuts off the dehumidifier when the bucket is fifll, or when
the bucket is removed or not replaced in the proper position. Mso, when the bucket is out
of position, the refit will beep 3 times.
Auto Defrost
X4]_en frost builds up on the cooling coils,
the compressor will cycle off' tmtil the frost disappears. The tim continues to run.
4
PowerOutage
If a power outage occmTed or if the refit was
tmI)lugged, the refit will display its prior setting.
Note:If ONis in the displa> the dehumidifier is
operating confinuousl B but a specific hmnidity level is not set. You will need to reset the
HgMIOID'CONrBOL t,, the desired level.
Auto Restart
Once power is restored after a power outage, the refit automatically resumes operation alter
a 2 minute delay:
Loading...
+ 8 hidden pages