Safety Instruc_tions ........... 2, 3
gO.COrn
Operating Instruotions
About the Controls
on the Dehumidifier ........... 4
Automatic Deflost .............. 5
Choosing a Location ............ 5
How the Dehumidifier Operates . . .5
Installing the _v\ater Bucket ....... 6
Removing Collected _Aater . ..... 6
V\ater Level ................... 6
Care and Cleaning
Air Filter ..................... 7
Cleaning the Coil .............. 7
Grille and Case ................ 7
*Aater Bucket .................. 7
Troubleshooting Tips .......... 8
Consumer Support
Consumer Support ............ 12
Warranty .................... 11
*ENERGY STAR ('_ labeled product
aHw3ou
AHH401_*
ENERGYSTAR
As an ENERGY STAR_ partner, GE has
determined that this product meets the
ENERGY STAR_ guidelines fin" energy
efticiency.
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the back
of the dehumidifier behind the bucket.
3828A20315T 49-7532 11-05JR
iMPORTANTSAFETYiNFORMATiON.
READALLiNSTRUCTiONSBEFOREUSING.
WARNING!
For your safetg the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injurg
SAFETYPRECAUTIONS
When using this dehumidifier, always follow basic safe_ precautions, including the following:
[] Use this appliance only fbr its intended [] Turn the dehumidifier OFFand unplug it
purpose as described in this Owner's
Manual.
[]
Th[_ dehumidifier mttst be properly
irLstalled and grounded as described
in this manual before it is ttsed.
[]
Never operate tlfis dehumidifier in an area
that is likely to accumulate standing water.
If this condition de_lops, for your safety
disconnect the power supply' before
stopping into the wamr.
[]
Never unplug y'our dehumidifier by pulling
on the power cord. Always grip plug firmly
and pull straight out flom the receptacle.
[]
Replace immediately all electric service
cords that have become flaved or otherwise
damaged. A damaged power supply cord
nmst be replaced with a new power supply
cord obtained flom the manufi_cturer and
not repaired. Do not use a cord that shows
cracks or abrasion damage along its length
or at either the plug or connector end.
before making any' repairs or cleaning.
[]
GE does not support any servicing of
the dehumidifier. _¢\%strongly recommend
that you do not at/erupt to seiMce the
dehumidifier yourself.
[]
For your safety, do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
[]
All dehumidifiers con rain refrigerants,
which under federal law must be removed
prior to product disposal. If you are g>tting
rid of an old product with refl_igerants,
check with the company handling disposal
about what to do.
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
For personal safely, this appliance must be
properly grounded.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall
outlet to minimize the possibility of electric
shock hazard flom this appliance.
Hme the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
2
_]lere a 2-piong wall outlet is encounmred,
it is your personal responsibility and obligation
to have it replaced with a properly gTounded
3-prong wall outlet.
The dehumidifier should always be
plugged into its own individual electrical
outlet, which has a xoltag> rating matching
the rating plato.
This provides the best per%rmance and also
piexents oxerloading house wiring circuits,
which could cause a fire hazard flom
oxerheated wires.
USEOFEXTENSIONCORDS
ge.com
Because of potential safety hazards under
certain conditions, we strongly recommend
against the use of an extension cord.
USEOFADAPTERPLUGS
Because of potential safety hazards under
certain conditions, we strongly recommend
against the use of an adapter plug.
However, if you must use an adapter,
where local codes permit, a temporary
connection may be made to a properly
grounded 9-i)rong wall outlet 1)yuse of
a Ui,-lismd adapter available at most
local hardware stores.
The larger slot in the adapter must be
aligned with the larger slot in the wall
outlet to provide proper polarity in the
connection of the power cord.
However, if you must use an extension
cord, it is absolumly necessa_ T that it be
a Ui,-lismd, 14 gauge, 3-wire grounding
type appliance extension cord having a
grounding type plug and outlet and that
the electrical rating of the cord be
15 amperes (minimum) and 195 volts.
When disconnecting the power cord fiom
the adapter, always hold the adaptor in place
with one hand while pulling the power cord
plug with the other hand. If this is not done,
the adaptor ground mrmina] is very likely to
break with repeated use.
If the adapter ground terminal 1)reaks,
DO NOT USE the dehumidifier until a proper
ground has been established.
Attaching the adapter groundterminal to a waft
outlet cover screw does not ground the appliance
unless the cover screw is metal, not insulated, and
the waft outlet is grounded through the house wiring.
Youshould have the circuit checkedby a qualified
electrician to make sure the outlet is properly
grounded.
READANDFOLLOWTHISSAFETYINFORMATIONCAREFULLY.
SAVETHESEINSTRUCTIONS
About the controls onthedehumidifier.
Bucket
Full Fan
ControlsO POWER Pad
Press to mrn the dehmnidifier on and off,
HUMIDITY CONTROLPads
The lmmidi_' lexel can be set within a range
of 35% RH (Relafixe Hmnidity) to 70% RH
(Relatixe Hmnidit)) in 5% increments,
For drier ai_, press the • pad and set to
a lower percent xflue (%).
For damper ai_; press the • pad and set
to a higher, I)ercent.... xal ue (%).
When vou first use the dehumidifier; set the
hmniditv control to 45% or 50%. Mlow at
least 24 hem5 fin" the dehumidifier to
achieve the humidity level. If you still have
damper air than desired, set the humidity
level to a lower setting.
• High
Humidity
Control
O FAN SPEEDPad
Controls the tim speed,
Press to set to HIGH or LOWfim speed.
Set the tim control to HIGHfin" maMm um
moisture remowfl. When the hmniditv has
been reduced and quiet operation is
preferred, set the tim control to LOW,
O HUMIDITY LEVELDISPLAY
Displa)s percent hmnidit) lexel.
Its accuracy is (+/- 5%).
O BUCKETFULLLED
Indicates presence of bucket and its
fill lexel.
OtherFeatures
BUCKETFULLLight
Glows when the bucket is ready to be emptied,
or when the bucket is removed or not replaced
in the proper position.
Auto Shut Off
The XAater I,e\'el Control Switch shuts off the
dehumidifier when the bucket is fifll, or when
the bucket is removed or not replaced in the
proper position. Mso, when the bucket is out
of position, the refit will beep 3 times.
Auto Defrost
X4]_en frost builds up on the cooling coils,
the compressor will cycle off' tmtil the frost
disappears. The tim continues to run.
4
PowerOutage
If a power outage occmTed or if the refit was
tmI)lugged, the refit will display its prior setting.
Note:If ONis in the displa> the dehumidifier is
operating confinuousl B but a specific hmnidity
level is not set. You will need to reset the
HgMIOID'CONrBOL t,, the desired level.
Auto Restart
Once power is restored after a power outage,
the refit automatically resumes operation alter
a 2 minute delay: