You can find the rating label on the
side of the air conditioner.
AIR CONDITIONER
GE is a trademark of the General Electric Company. Manufactured under trademark license.
49-5000442 Rev. 0 09-19 GEA
0011500765
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration
card included in the packing material.
249-5000442 Rev. 0
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
SAFETY INFORMATION
WARNING
fire, electric shock or personal injury.
■ Use this appliance only for its intended purpose as
described in this Owner’s Manual.
■ This air conditioner must be properly installed in
accordance with the Installation Instructions before it is
used.
■ Never unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and pull straight
out from the receptacle.
■ Replace immediately all electric service cords that
have become frayed or otherwise damaged. A
damaged power supply cord must be replaced with a
new power supply cord obtained from the manufacturer
and not repaired. Do not use a cord that shows cracks
or abrasion damage along its length or at either the
plug or connector end.
■ Do not use means to accelerate the defrosting process
or to clean, other than those recommended by the
manufacturer.
■ The appliance shall be stored in a room without
continuously operating ignition sources (for example:
open flames, an operating gas appliance or an
operating electric heater.
■ Do not pierce or burn refrigerant tubing. Be aware that
refrigerants may not contain an odor.
■ Keep ventilation openings clear of obstruction.
■ When handling, installing, and operating the appliance,
care should be taken to avoid damage to the
refrigerant tubing.
For your safety, the information in this manual must be followed to minimize the risk of
WARNING
Risk of Fire or Explosion. This unit contains flammable refrigerant.
Additional safety precautions must be followed.
■ Turn the unit OFF and unplug your air conditioner
before cleaning.
■ For your safety…do not store or use combustible
materials, gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.
■ If the receptacle does not match the plug, the
receptacle must be changed out by a qualified
electrician.
■ Do not drill holes in the unit.
■ Maintenance, cleaning, and service should only be
performed by technicians properly trained and qualified
in the use of flammable refrigerants.
■ GE Appliances does not support any servicing of the
air conditioner.
■ Dispose of air conditioner in accordance with Federal
and Local Regulations. Flammable refrigerants require
special disposal procedures. Contact your local
authorities for the environmentally safe disposal of your
air conditioner.
READ AND SAVE THESE INSTRUCTIONS
49-5000442 Rev. 03
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING
RISK OF FIRE. Could cause serious injury or death.
■ DO NOT use an extension cord with this Window Air
Conditioner.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord. For personal safety,
this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
SAFETY INFORMATION
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall outlet to minimize the possibility
of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test
and reset button is provided on the plug case. The device
should be tested on a periodic basis by first pressing the
TEST button and then the RESET button while plugged
into the outlet. If the TEST button does not trip or if the
RESET button will not stay engaged, discontinue use of the
air conditioner and contact a qualified service technician.
USE OF EXTENSION CORDS
■ DO NOT use surge protectors or multi-outlet adaptors
with this Window Air Conditioner.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its
own individual electrical outlet which has a voltage rating
that matches the rating plate.
This provides the best performance and also prevents
overloading house wiring circuits which could cause a
fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection
requirements.
READ AND SAVE THESE INSTRUCTIONS
449-5000442 Rev. 0
Controls
Features and appearance will vary.
USING THE AIR CONDITIONER
56
4
3
7
8
Air Conditioner Controls
Controls
1. Temperature Control
This determines how much cooling is provided.
Max Cool - 10 provides the most cooling and
Min Cool - 1 provides the least.
Cooling Descriptions
For Normal Cooling—Select 4-7 on the dial with
HCool r LCool selected.
For Maximum Cooling—Select 8-10 on the dial with
HCool selected.
2
1
Min Max
Cool Cool
L FanH Fan
OFF
10
H CoolL Cool
2. Mode Control
9
HCool and LCool provide cooling with different fan
speeds.
HFan and LFan provide circulation and filtering without
cooling.
NOTE: If you move the Temperature control from a
cool setting to a fan setting or power off the unit while
cooling, wait at least 3 minutes before switching back
to a cool setting.
For Quieter and Nighttime Cooling—Select 1-3 on
the dial with LCool selected.
Air Direction
Use the lever to adjust the air direction left to right.
49-5000442 Rev. 05
Care and Cleaning
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing
outdoor conditions. It must not be used when the outdoor
temperature is below freezing (32°F).
Grille and Case
Turn the air conditioner off and remove the plug from the
wall outlet before cleaning.
Air Filter
The air filter behind the front grille should be checked
and cleaned at least every 30 days or more often if
necessary.
CARE AND CLEANING
To remove:
Slide the filter from the left side of the unit. Remove the
filter.
Clean the filter with warm, soapy water. Rinse and let the
filter dry before replacing it. Do not clean the filter in a
dishwasher.
To clean, use water and a mild detergent. Do not use
bleach or abrasives.
CAUTION
without a filter because dirt and lint will clog it and reduce
performance.
DO NOT operate the air conditioner
Outdoor Coils
The coils on the outdoor side of the air conditioner should
be checked regularly. If they are clogged with dirt or soot,
they may be professionally cleaned.
649-5000442 Rev. 0
Installation Instructions
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
INSTALLATION INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
•
IMPORTANT –Save these
instructions for local inspector’s use.
•
IMPORTANT –Observe all
governing codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill level – Installation of this appliance requires
basic mechanical skills.
• Completion time – Approximately 1 hour
• We recommend that two people install
this product.
• Proper installation is the responsibility
of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
• You MUST use all supplied parts and use proper
installation procedures as described in these
instructions when installing this air conditioner.
ELECTRICAL
REQUIREMENTS (CONT)
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case.
The device should be tested on a periodic basis
by first pressing the TEST button and then the
RESET button while plugged into the outlet. If the
TEST button does not trip or if the RESET button
will not stay engaged, discontinue use of the air
conditioner and contact a qualified service technician.
TOOLS YOU WILL NEED
Phillips head screwdriver
Drill and 1/8” drill bit
ELECTRICAL REQUIREMENTS
These models require a 115/120-volt AC,
60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility
of electric shock hazard. If the wall outlet you plan to
use is only a 2-prong outlet, it is your responsibility
to have it replaced with a properly grounded 3-prong
wall outlet.
CAUTION
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.
Do not change the plug on the power cord of this air
conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
Level
Ruler or tape measurePencil
Scissors or knife
49-5000442 Rev. 07
Installation Instructions
PARTS INCLUDED
(Appearance may vary)
Top mounting rail
Air
conditioner
INSTALLATION INSTRUCTIONS
Foam top window
gasket
Side
Curtain (2)
Side Curtain
Left
Frame
Right
Type A (3)
Type B (9)
Side Brackets (2)
Window locking
bracket (1)
849-5000442 Rev. 0
Installation Instructions
CLICK
INSTALLATION INSTRUCTIONS
1. WINDOW REQUIREMENTS
• These instructions are for a standard
double-hung window. You will need to modify
them for other types of windows.
• The air conditioner can be installed without the
side curtain panels if needed to fit in a narrow
window. See the window opening dimensions.
• All supporting parts must be secured to firm
wood, masonry or metal.
• The electrical outlet must be within reach of the
power cord.
• Follow the dimensions in the table and
illustration for your model.
13 3/8”
21 7/8” - 36”
(With side curtain panels)
3. PREPARE THE AIR
CONDITIONER
A. Install the top mounting rail with 3 Type A screws
Top Mounting rail
B. Slide the side curtain panels into the side panel
rails.
2. STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will
keep it from draining properly. To adjust for this,
attach a piece of wood to the sill.
WOOD PIECES
WIDTH: 2″
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place
a piece of wood on the sill to make it 1/2″ higher
than the top of the storm window frame or the
vinyl frame.
Attach securely with nails or screws provided by
the installer.
1/2″ higher
than vinyl frame
(on some windows)
1/2″ higher
than storm
window
frame
Storm window
frame
Sill
Vinyl frame
Wood
C. Slide left and right side curtain frames into top
and bottom rails. Make sure that side curtains
snap into side of the frames.
49-5000442 Rev. 09
Installation Instructions
4. INSTALL THE AIR CONDITIONER
IN THE WINDOW
A. Measure the width of the window opening and
mark the center line on the inside window sill.
Place the unit in the window. Lower the window
to hold unit in place.
Width of window opening
Center line
B. Set the air conditioner in the window so that is
centered. Place the air conditioner so that front
edge of the bottom mounting rail is against the
back edge of the sill.
INSTALLATION INSTRUCTIONS
4. INSTALL THE AIR CONDITIONER
IN THE WINDOW (continues)
D. Bring the window down so that the front edge
of the top mounting is in front of the window.
Make sure that the air conditioner is level or
tilting slightly to the outside.
Type B screws
E. Extend the curtain panels until they fill the
window. Mark the location of the holes in each
corner. Use the drill and 1/8” drill bit to drill pilot
holes. Use 4 type B screws to secure the side
panels in place.
C. Install the side bracket into the unit and into the
window sill using two 1” wood screws provided.
repeate on other side.