GE AHW50LLG1, AHW40LLG1, AHW30LLG1, AHR40LLG1 Owner’s Manual

Safety Instruc_tions ........... 2, 3
ge.com
Operating Instruc_tions
About the Controls
on the Dehumidifier . ........... 4
Automatic Deflost ................ 5
Choosing a Location ............. 5
How tile Dehumidifier Operates . . .5
Remoxing Collected Water . ..... 6
Water Lmel .................... 6
Care and Cleaning
Grille and Case ................. 7
Troubleshooting Tips ........... 8
Consumer Support
Consumer Support ............. 12
Warranty ..................... 11
ENERGY STAR ® labeled product
AHR30 AHW30 AHH40 AHR40 AHW40 AHRSO AHWSO AHR65 AHW65
ENERGYSTAR
As an ENERGY STAR ® partner, (;E has
determined that this product meets the ENERGY STAR ® guidelines for enero_
efliciencx.
Write the model and serial numbers here: Model # Serial #
You can find them on a label on the back
of the dehmnidifier.
49-7589 12-07JR
IMPORTANTSAFETYINFORMATION. READALLINSTRUCTIONSBEFOREUSING.
WARNING!
For your safe_ the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
SAFETYPRECAUTIONS
When using this dehumidifier, always follow basic safety precautions, including thefollowing:
Use this appliance only for its intended Turn tile dehumidifier OFFandunI)lug it
i)urpose as described in this Owner's Mannal.
This dehumidifier must be properly installed and grounded as described
in this manual before it is used.
before cleaning. GE does not support any servicing of
the dehumidifier. VVestrongly recommend that you do ,lot attempt to serxdce the
dehumidifier yourself.
Never operate this dehmnidifier in an area that is likely to accumulate standing water.
If this condition dex>lops, for your safbrv
disconnect the power supply befose
stepping into the water. Nexer unplug your dehumidifier 1)ypulling
on tile power cord. Always grip plug firmly and pull straight out from the receptacle.
Replace immediately all elecedc service cords that haw become flaved or odserwise damaged. A damaged power supply cord must be replaced with a new power supply
cord obtained flom the mannfact/5ier and
not repaired. Do not use a cord flint shows cracks or abrasion damag_ along its length or at eiflser rise plug or connector end.
If the receptacle does not match tile plug,
the receptacle must be changed out by a
qualified electrician.
HOWTOCONNECTELECTRICITY
For your safety, do not store 05 use combnsdble materials, gasoline or other flammable vapors or liquids ill the vicinity of this or any other appliance.
All dehumidifiers contain refiigerants,
which under federal law must be remox>d prior m product disposal. If you are g_tdng
rid of all old product with refrigerants, check with tile company handling disposal
about what to do.
Do not ttse outdoors.
This dehumidifier is intended %5 indoor residential applications only.
This dehumidifier should not be used for commercial or industrial applications.
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
For personal safety, this appliance must be properly grounded.
DO NOT use an adapterplug with this appliance.
Tile power cosd of dfis appliance is equipped with a 3q)rong (grounding) plug which mates with a standard 3-prong (grounding) wall
outlet to minimize tile possil)iligv of electric
shock hazard fiom this appliance.
Haxe the wall outlet and circuit checked 1)v a
qualified electrician to make sure the outlet is
properly grounded.
_411eie a 2-plong wall outlet is encounmred, it is your personal responsibility and obligation to haxe it 5ei)laced with a properly grounded 3-prong wall outlet.
The dehumidifier should always be plugged into its own individual electrical oudet, which has a x_ltag> rating matching the rating plato.
This proxqdes the best performance and also piexents oxerloading house wiring circuits,
which could cause a fire hazard flom oxerheated wires.
2
USEOFEXTENSIONCORDS
ge.com
Because of potential safety hazards under certain conditions, we strongly recommend
against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessa_ T that it be
a UL-lismd, 14 gauge, 3-wire grounding type appliance extension cord having
a grounding type plug and outlet and that the electrical rating of the cord be
15 amperes (minimum) and 195 volts.
READANDFOLLOWTHISSAFETYINFORMATIONCAREFULLY.
SAVETHESEINSTRUCTIONS
Aboutthe controlsonthe dehumidifier.
4houror2 hour High,Medklm
delayoff andLowfan
indicatorlights indicatorlights
4 hour
2 hour
/VOTE'._'_hen the bucket is tull or removed, the
conti'ols cannot be set.
Controls
O Power Pad
Press to turn the dehumidifier on and oil
O Filter Timer
After 250 hours of operation, the Cleanthe
Filterindicator light MII gl()_ to remind you to
clean the filtei: Remove the filter and clean it. Press to turn off the Clean the Filterlight. See
the Care and Cleaning section.
Humidity Set Control Pads
@
The humidiff level can be set within a range of 35% RH (Relative Humidity) to 80% RH
(Relative Humidity) in 5% increments or at
COfi)r continuous operation.
/VOTE'.If CO (Continuous) is selected, the
dehumidifier will operate continuously at its maMm um dehumidification settings if
attached to a hose to drain or until the bucket is flfll.
For drier ai_; press the pad and set to a lower percent vahle (%).
For damper ai_; press the pad and set to a higher percent vahle (%).
CleantheFilter Continuousoperationon
indicatorlight indicatorlight
Humidity %
'u m
Conti ous Bucket Full
Clean the Filter indicatorlight
ling
When you fi_st use the dehumidifie_; set the humidity control to 45% or 50%. Mlow at least 24 l_otu_ fi)r the dehumidifier to
achieve the humidity level. If you still have damper air than desired, set t'he humidiQ'
level to a lower setting or select ContintlOtlS for maximum dehumidification.
0 Display
Sho_s the set % humidity level _dfile setting, then shows the actual (+/- 5%
accm'ac)) room % humidity lmel.
Fan Speed Pad
O
Controls the tim speed. Press to select either High, Medium or Low
fan speed. Set the tim control to Highfor maximum
moisture remowfl. When the humidity has been reduced and quiet operation is
preferred, set the fan control to Medium or Low.
Delay Off
0
%hile the dehumidifier is in operation, press this pad to set it to automatically mrn
off in 2 hom_ or 4 hom_.
BucketFulllightindicates
bucketneedstobeemptied
orisnotinplaceintheunit
PowerOn
OtherFeatures
BUCKETFULLLight
(;lows when the bucket is ready to be emptied, or when the bucket is removed or not replaced
in the proper position.
Alarm
]f the bucket is fifll or missing tbr more than three
minutes, an alarm will sound filr about l 0 seconds to remind you to erupt} and replace the bucket.
Auto Shut Off
4
The Water I,evel Control Switch shuts off' the
dehumidifier when the bucket is fifll, or when
the bucket is removed or not replaced in the proper position.
Auto Defrost
%l_en fix)st builds up on the evaporator coils, the compressor will cycle off and the tim will
continue to rtm until the fi'ost disappears.
Power Outage
In the case of a power outage or interruption, the unit will automatically re-start, in the settings
last used, after the power is restored.
Usingthe dehumidifier, gecom
When first using the dehumidifier, operate the unit continuously 24 hours.
How the Dehumidifier Operates Automatic Defrost
Moist, lmmid air is drawn over a cold refi_igerated
delmmidif)ing coil. Moisture in the air condenses on this coil and drains into a bucket (or through
a hose and drain).
Dr,x; clean air is drawn through the condenser where it is heated and discharged out the top grille
into the room.
It isnormalfor the surroundingairto becomeslightly warmeras thedehumidifieroperates.
Choosinga Location
A dehumidifier operating in a basement will have
little or no effect in dr)ing an ac!jacent enclosed storage area, such as a closet, unless there is
adequate circulation of air in and out of the area.
Donotuseoutdoors.
Thisdehumidifieris intendedforindoorresidential applicationsonly.Thisdehumidifiershouldnotbe
usedfor commercialorindustrialapplications.
Placethedehumidifierona smooth,levelfloor strong enoughto supporttheunit with a full bucket of water.
Allowatleast 12-18inchesof airspace on allsides of the unitfor goodair circulation.
Placethedehumidifierin anareawhere the temperaturewill not fallbelow 4I°F (5°0. Thecoils
can becomecoveredwith frostat temperatures below41°F,which mayreduceperformance.
Usethedehumidifierin cooking,laundrg,bathing and dishwashingareas that haveexcessive
moisture.NOTE:Placethedehumidifieraway fromthe clothesdryer.
Usethe dehumidifiertoprevent moisturedamage anywherebooksor valuablesare stored.
Usethedehumidifierin a basementto help prevent moisturedamage.
Thedehumidifiermustbeoperatedinan enclosed areato be mosteffective.
Closeall doors,windows and other outsideopenings tothe room.
&&]_en fl'ost builds up on the evaporator coils, the
compressor will Q:cle off and the tim will continue to run until the ti'ost disappears.
_]_en the coil is defrosted, the compressor or tim
will automatically restart and dehumidifying will
I'eStllI/e.
YES NO
12 18" rain. 12 1U rain.
NOTE"Thedehumidifierhas rollerstoaid placement, but it shouldonlyberolled onsmooth,flat surfaces.
Donot attempttoroll the dehumidifieron carpet or
overobjects.
Usingthe dehumidifier.
Always make sure the water bucket is locked into place on the dehumidifier.
Removing Collected Water
Thereare2 ways toremovecollected water."
[] Usethebucket"_&hen the bucket isremoxed,
the unit will shut off. Erupt' and replace the
bucket.
NOTE:Supportbucketwith bothhandswhen empHing.
IMPORTANT"Do not use thehoseif usingthe buckettocollect water. Whenthe hoseis
connected,waterwill flow throughit ontothe floorinsteadof into thebucket.
NOTES:
Donotremovethebucket whilethe dehumidifieris operatingorif it hasjust
stoppedoperating.Thismightcausesome water to drip fromthe drainpan.
Thebucketmustbe in place andsecurely seatedfor thedehumidifiertooperate.
[]
Use a hose. _&'ater can be automaticall_ emptied into a floor drain by attaching
a garden water hose (not included).
1. Remove tile bucket fl'om tile fl'ont of tile unit.
2. Open tile drain cover on tile side of tile unit.
3. Thread a garden hose (not supplied) onto tile nozzle, cut to length, and lead it to tile
floor drain.
Sideofunit
4. Replace tile bucket in tile unit.
NOTE:Thebucketmustbein place andsecurely seatedfor thedehumidifiertooperate.
Water Level
The deh tunidifier will tui'n off a utomaticall_ when tile bucket is fldl, or when tile bucke{ is
remoxed or not replaced in tile proper position.
Thebucket mustbe replacedin the properpositionfor thedehumidifierto work. Thelightwill be on and the dehumidifierwill not runff thebucketis notin the
proper position.
Careand cleaning of the dehumidifier, ge.com
Turn the dehumidifier off and remove the plug from the wall outlet before cleaning.
Grille and Case
Toclean the case:
Use water and a mild detergent. Do not use bleach or abrasives.
Water Bucket
Toclean'.
Every few week_, clean the bucket to prevent growth of mold, mildew and bacmria. Partially fill
the bucket with clean water and add a little mild detergent. Swish it around in the bucket, empty
and rinse.
NOTE:Do not use a dishwasher to clean the
water bucket.
Toremove:
Remove the bucket and pour any water out.
Toreplace:
Slide the bucket into the dehumidifier
NOTE:Thebucket mustbe inplace and securelyseated for the dehumidifierto operate.
Toclean the frontgrille:
Use a w_cuum attachment or brush.
\
Air Filter
The air filter behind the fi'ont grille should be checked and cleaned at least eve_' 250 hom_ of
()l)eI';Itioll or I//oI'e oJ[[en if necess}lI "V,
_Mier 250 houi_ ot operation, the Clean the Filter
indicator light will glow to remind you to clean the film_: Remove the filter and clean it. Replace the
filter and press the Filter Timerpad to turn off the
Clean the Filter light. Toremove:
Remove the bucket. Grasp the filter edge, and pull it straight down and out.
Toclean:
Clean the filter with wamL soapy water: Rinse and let the filter dry beti)re replacing it.
NOTE."DONOT rinse orput the filter in an automatic
dishwasher
CAUTION:DoNoroperatetbedebumidifier
without afilter becausedirt and lint will clog it and reduce
performance.
NOTE:Avoidusinga dishwasherto cleanthe filter
7
Troubleshootingtips...S e ime,,,money!Reviewthechartbelowfirstandyoumaynotneedtocallforservice,
Problem Possible Causes What To Do
Dehumidifier The dehmnidifier Make sure the delmmidifier's plug is i)ushed completely
does notstart is unplugged, into the outlet.
The fuse is blown/circuit "Check the house fllse/circuit breaker box and replace breaker is tripped, the filse or reset the breaker:
Dehumidifier has reached its "The dehumidifier automatically turns off when either preset level or bucket is full. condition occurs. Change to a lower setting or erupt)'
the bucket and replace prol)erly:
Bucket is not in the The bucket Inust be in place and securely seated fin" the proper position, dehumidifier to operate.
Power failure. There is a protective tilne delay (up to 3 Ininutes) to
prevent tripping of the compressor overload. For this reason, the unit may not start n/mnal dehtuniclil_ng
fin" 3 minutes alter it is turned back on.
Dehumidifier does not Did not allow enough time "X._q/en f]ist installed, allow at least 24 l_otus to maintain dry the airas #should to remove the moisture, the desired dryness.
Airflow is restricted. Make sure there are no curtains, blinds or flu'niture
blocking the front ()r back of the dehumidilie_: See the
Choosing a Location section. Dirty f'dter. See the Care and Cleaning section. The HmnidJty Con_ol may For drier ai_; press the pad and set to a lower percent
not be set low enough. \:llue (%) OI" lit CO (con[intlOtlS) toI" Ill}lXillltlll]
deh umidilication.
Doors and windows may not Check that all (loo_s, windows and other openings be dosed tightly, are securely closed.
Clothes dryer may be Install the dehumidifier away fl'om the (lrve_: blowing moisture-laden The dryer should be xented'to the outside. air into the room.
Room temperature Moisture remowll is best at higher room temperatures. is too low. I,ower room teml)eratures will reduce the moisture
remowll rate. Models are designed to be operated at temperatures al)ove 41°F (5°C).
Dehumidifier runs Area to be dehumidified "The capacib roI your dehumidifier may not be adequate. too much is too large.
Doors and windows axe open. Close all do(n_ and windows to the outside.
Frost appears on DehmnidJfier has been recently "This is nomml. Frost will usually disapl)ear the coils turned on, or room temperature within 60 minutes. See the Automatic Defrost section.
is below 41°F (5°C).
Controls cannot be set The compressor will turn off "This is nomml. Wait approximately 3 minutes and set the
mad the fan will automatically tim as desired. continue to run for
approximately 3 minutes at a fLxed setting.
Fan noise Air is moving through This is nomml.
Water on floor Hose connection may be loose. Check the hose c(mnecfion. See the Removing Collected
the dehumidifier.
Intend to use the bucket to collect water, but a hose
is attached.
Water section.
"Discomaect the hose if using the bucket to collect water:
See the Removing Collected Watersection.
8
Loading...
+ 16 hidden pages