Safety Instructions . . . . . . . . . . . . . 2, 3
Operating Instructions
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Care and Cleaning
Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Outdoor Coils . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation Instructions . . . . . . 6–10
Troubleshooting Tips . . . . . . . . . . . .11
Normal Operating Sounds . . . . . . . . . . . .11
Consumer Support
Consumer Support . . . . . . . . . . . . . . . . . . .14
Warranty for Customers
in the U.S.A. . . . . . . . . . . . . . . . . . . . . . . . . . .13
Owner’s Manual and
Installation Instructions
AHR05
Write the model and serial numbers here:
Model # _________________________
Serial # __________________________
Find these numbers on a label on the side of the air conditioner.
Air Conditioners
In Canada, contact us at: www.GEAppliances.ca
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
SAFETY PRECAUTIONS
n Use this appliance only for its intended
purpose as described in this Owner’s Manual.
n This air conditioner must be properly
installed in accordance with the Installation Instructions before it is used.
n Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly and pull straight out from the receptacle.
n Replace immediately all electric service
cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
n Turn the unit OFF and unplug your air
conditioner before cleaning.
n GE does not support any servicing of the
air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
n For your safety…do not store or use
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
n All air conditioners contain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
n If the receptacle does not match the plug,
the receptacle must be changed out by a qualified electrician.
n These R410A air conditioning systems
require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue
2
use of the air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
GEAppliances.com
WARNING!
USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
DO NOT use an extension cord with this Window Air Conditioner.
DO NOT use surge protectors or multi-outlet adaptors with this Window Air Conditioner.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY SAVE THESE INSTRUCTIONS
.
3
About the controls on the air conditioner
Features and appearance will vary.
Speed
Low
Cool
Fan Only
High Cool
Power
Wait 3 Mins. Before
Restarting
Controls
Temperature Control
Setting determines how much cooling is provided. High Cool provides the most cooling and Low Cool provides the least.
Fan Only turn off the cooling. NOTE: If you move the Temperature control
from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.
Hi
On
w
Lo
Off
Fan Speed
The fan speed button can be set on HI or LOW. In both cooling mode and fan only mode.
Power
Turns the unit on or off.
Cooling Descriptions For Normal Cooling—Select High Cool or Low
Cool. For Maximum Cooling—Select High Cool with the
FAN SPEED set to HI.
For Quieter and Nighttime Cooling—Select Low Cool with the FAN SPEED set to LOW.
Air Direction
Use the lever to adjust the air direction left and right only.
lever is in middle
4
Care and Cleaning the air conditioner GEAppliances.com
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Air Filter
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.
5
Installation
Air Conditioner
Instructions
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these instructions
for local inspector’s use.
IMPORTANT — Observe all governing
codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill level – Installation of this appliance
requires basic mechanical skills.
• Completion time – Approximately 1 hour
• We recommend that two people install
this product.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not covered under the Warranty.
• You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
TOOLS YOU WILL NEED
Phillips head screwdriver
Drill and 1/8” drill bit
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt AC,
60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt AC,
protected with a time-delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Pencil
Level
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the
RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not
stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
6
Ruler or tape measure
Scissors or knife
PARTS INCLUDED
(Appearance may vary)
Top channel
Installation Instructions
Foam seal
Air
conditioner
Type A screws (3)
Side curtains (2)
Type B screws (7)
Side curtains frames (2)
Window lock bracket (3)
7
Installation Instructions
1
WINDOW REQUIREMENTS
•These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
•The air conditioner can be installed without the side curtain if needed to fit in a narrow window. See the window opening dimensions.
•All supporting parts must be secured to firm wood, masonry or metal.
•The electrical outlet must be within reach of the power cord.
•Follow the dimensions in the table and illustration for your model.
12” 3/8”
23 1/4”- 36”
(With side curtain)
3
PREPARE THE AIR CONDITIONER
Install the top mounting rail with 3 Type A
A
screws from the outside of the case.
Top mounting rail
B
Slide curtain panel into side rails.
2
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.
WOOD PIECES
WIDTH: 2” LENGTH: Long enough to fit inside the window
frame. THICKNESS: To determine the thickness, place a
piece of wood on the sill to make it 1/2” higher than the top of the storm window frame or the vinyl frame.
Attach securely with nails or screws provided by the installer.
1/2” higher than vinyl frame (on some windows)
1/2” higher than storm window frame
Storm window frame
Sill
Vinyl frame
Wood
C
Slide left and right side curtain frames into top and bottom mounting rail. Make sure curtain snaps into place.
Top left
Bottom mounting rail
Top mounting rail
Top right
8
Installation Instructions
5
PREPARING THE WINDOW FOR INSTALLATION
Measure the width of the window opening and
A
mark the center line on the inside windowsill.
Width of window opening
Center line
B
Install the window lock bracket behind the inner windowsill, with the short side of window lock. Use 2 type B screws provided. The window lock bracket helps hold unit securely in place. Be sure to place window lock bracket edge flush against back or inner sill.
Type B screws
Inner sill
Outer sill
Window lock
brackets
Center line
6
INSTALL THE AIR CONDITIONER IN THE WINDOW
A
Set the air conditioner in the window so that is centered. Place the air conditioner so that front edge of the bottom mounting rail is against the back edge of the sill.
Window frame
Top channel
About 1/4”
Bottom guide
Window lock
bracket
Bring the window down so that the front
B
edge of the top mounting is in front of the window. Make sure that that air conditioner is level or tilting slightly to the outside.
Short side
7.5”
7.5”
Type B screws
C
Extend the curtain panels until they fill the window. Mark the location of the holes in each corner. Use the drill and 1/8” drill bit to drill pilot holes. Use 4 type B screws to to secure the side panels in place.