Ge Ahk65lkm1, Ahk50lkm1, Ahk40lkg1, Ahk30lkg1 Owner's Manual

Safety Instru_tions ........... 2, 3
ge.com
Operating Instruc_tions
About the Controls
on the Dehumidifier . .......... 4
Automatic Deflost .............. 5
Choosing a Location ............ 5
How the Dehumidifier Operates . . .5
Removing Collected Water ...... 6
Water Level ................... 6
Care and Cleaning
Grille and Case ................ 7
Water Bucket .................. 7
Troubleshooting Tips .......... 8
Consumer Support ............ 12
Product Registration ......... 9, 10
_\arranty .................... 11
*ENERGY STAR _ labeled product
AHK30 AHK40 AHKSO* AHK65*
ENERGYSTAR
As an ENERGY STAR _ partneL GE has
determined that this product meets the ENERGY STAR _ guidelines for energy
efficiency.
Write the model and serial numbers here: Model # Serial #
You can find them on a label on the back
of the dehmnidifier.
220264A036
49-7557 11-06JR
iMPORTANTSAFETYiNFORMATiON. READALLiNSTRUCTiONSBEFOREUSING.
WARNING!
For your safetg the information in this manual must be followed to minimize the risk of fire, electric shock or personal injurg
SAFETYPRECAUTIONS
When using this dehumidifier, always follow basic safe_ precautions, including the following:
[] Use this appliance only fbr its intended [] If tile receptacle does not match the plug,
purpose as described in fl_is Owner's the receptacle must be changed out by a Man ual. qualified electrician.
[] Th[_ dehumidifier mttst be properly []
irLstalled and grounded as described in this manual before it is ttsed.
[]
Never operate tlfis dehumidifier in an area that is likely to accumulate standing water.
If this condition de_lops, fbr your safety
disconnect the power supply' before
stopping into the wamr.
[]
Never unplug y'our dehumidifier by pulling on the power cord. Ahvays grip plug firmly and pull straight out flom the receptacle.
[]
Replace immediately all electric service cords that have become flaved or otherwise
damaged. A damaged power supply cord nmst be replaced with a new power supply
cord obtained flom the manufi_cturer and
not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
Turn the dehumidifier OFFand unplug it before making any' repairs or cleaning.
NOTE:_% strongly recommend that any
servicing be perfbrmed by a qualified individual.
[]
For your safety, do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
[]
All dehumidifiers con tain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting
rid of an old product with ,efi_igerants, check with the company handling disposal
about what to do.
[]
Do not use outdoors.
[]
This dehumidifier is intended %r indoor residential applications only'.
This dehumidifier should not be used %r commercial or industrial applications.
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
For personal safely, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall
outlet to minimize the possibility of electric
shock hazard flom this appliance.
Hme the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
2
Where a 2-prong wall outlet is encounmred, it is your personal responsibility and obligation to haw it replaced with a properly gTounded 3-prong wall outlet.
The dehumidifier should always be plugg>d into its own individual electrical outlet, which has a xoltag> rating matching the rating plato.
This provides the best per%rmance and also prments oxerloading house wiring circuits,
which could cause a fire hazard from
ox eflleated wires.
USEOFEXTENSIONCORDS
ge.com
Because of potential safety hazards under certain conditions, we strongly recommend
against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessa_ T that it be
a UL-lismd, 14 gauge, 3-wire grounding type appliance extension cord having
a grounding type plug and outlet and that the electrical rating of the cord be
15 amperes (minimum) and 195 volts.
READANDFOLLOWTHISSAFETYINFORMATIONCAREFULLY.
SAVETHESEINSTRUCTIONS
What dehumidifier do you need?
Conditionwithoutdehumidification--
Durin_lwarm andhumidoutdoorconditions 500 1000
Moderately damp--Space feels damp
and has musty odor only in humid weather. _0 AHK30
Very damp--Space always feels damp and has musty
odor. Damp spots show on walls or floor. _0 AHK30
Wet--Space feels and smells weL Walls or floor sweat,
orseepage ispresent. _0 AHK30 Extremely wet--Laundry drying, wet floor, high-load conditions _0 AHK30
Tableindicates recommended GEdehumidifier models, based on the area of the spaceto be dehumidified and the conditions that would exist in that space when a dehumidifier is not in use. Dehumidification variables also include such other factors as climate, laundry equipment, number of family members, number of doors andwindows and degree and intensity of
area activity.
Area (in squarefeet)
1500 2000 2500 3000 3500
HK30 AHK30 AHK40 AHK40 AHK40
K30 AHK40 AHK40 AHK40 AHK50
AHK40 AHK40 AHK40 AHKS0 AHK50 AHK40 AHK40 AHK50 AHK50 AHK65
Aboutthe controlsonthe dehumidifier.
Poweron
indicatorlight
Power
\
O Power Pad
Controls
Press to turn the delmmiditier on and off.
Continuous
Select flw the delmmidflier to operate continuously at its maMmum
dehumidification settings until the bucket is flfll. The HumidiP,' Set Control Pads cannot
be used when (_ontin/IO/IS is Oil.
Continuous Bucketfulllight
operationon indicatesbucket
®
Continuous
needstobe
emptied
Humidity %
Highfan Normalfan
indicatorlight indicatorlight
ONormal
Fan Speed Pads
Control the tim sl)eed.
Press to select either Highor Normaltml speed.
Set the tan control to Highfi)r maximum
moisture remowd. When the humidity
has been reduced and quiet operation is
preti_rred, set the tim control to Normal
HumiditySet ControlPads
@
Tile humidib' level can be set within a range of 35% RH (Relative Humidity) to 80% RH
(Relative HumidiV) in 5% increments.
For drier ai_, press the pad and set to a lower pelvent \_due (%).
For damper ai_; press the pad and set to a higher percent wdue (%).
When you fi_t use the dehumidifier, set the humidiP,' control U) 45% or 50%. Mlow at least 24 l/otu_ tot the dehumidifier to
achieve the humidity level. If you still have daml)er air than desired, set die humidi V
level to a lower setting or select Continuous tot maximum dehumidification.
0 Display
Shows the set % humidit) lexel while
setting, then shows the actual (+/- 5% accm'ac)) room % humidit_ lexel.
Error Codes
El- Humi(liw sensor error - Unl)lug the
unit and phlg it back in. If error repeats, call for service.
E2- Temperature sensor error- Unl)lug
the unit and l)lug it back in. If error repeats, call tot service.
PI- Unit is defl'osting - Mlow the unit time
to automatically defrost. The error will clear after the unit self defl'osts.
P2- Water bucket is flfll - Erupt) tile water
bucket and replace. See the Removing
Collected Water section.
OtherFeatures
BUCKETFULLLight
Glows when the bucket is ready to be empded, or when the bucket is removed or not replaced in the proper position.
Auto Shut Off
The Water i,e\'el Control Switch shuts off the dehumidifier when the bucket is flfll, or when the bucket is removed or not replaced in the
proper position.
4
Auto Defrost
X'_hen frost builds up on the evaporator coils, the compressor will cycle off and the tim will continue to run until the fl'ost disal)pea_.
Power Outage
In the case of a power outage or interruption, the unit will automatically re-start, in the settings last used, after the power is restored.