GE AHG30LH, AHG40LH User Manual

GEAppliances.com
Safety Instruc_tions ........... 2, 3
Operating Instruc_tions
About the Controls
on the Dehumidifier . .......... 4
AutomaOc Defrost .............. 5
Choosing a LocaOon ............ 5
How the Dehumidifier Operates . . .5
Installing the V(ater Bucket ....... 6
Removing Collected _4'ater ...... 6
V(ater Level ................... 6
Care and Cleaning
Air Fiher . .................... 7
Cleaning the Coil .............. 7
Grille and Case ................ 7
VVater Bucket .................. 7
Troubleshooting Tips .......... 8
Consumer Support ............ 12
Product Registration ......... 9, 10
_'arranty .................... 11
A HG3OLH A HG40L H* AHG5OLH*
*ENERGY STAR labeled product
®
ENERGYSTAR
As an ENERGYSTAR¢_partner, (;E has
determined that this product meets the
ENERGY STAR ® guidelines for enero"_
etticienc'_,
Write the model and serial numbers here: Model # Serial #
You can find them on a label on the back
of the dehumidifier behind the bucket.
3828A20315S 49-7504 11-04JR
IMPORTANTSAFETYINFORMATION. READALLINSTRUCTIONSBEFOREUSING.
WARNING!
For your safe_ the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
SAFETYPRECAUTIONS
When using this dehumidifier, always follow basic safety precautions, including the following:
Use this appliance only %r its intended
purpose as described in this Owner's Manual.
This dehumidifier must be properly installed and grounded as described
in this manual before it is used.
Never operate this dehumidifier in an area that is likely to accumulate standing water.
If this condition dex>lops, for your safety
disconnect the power supply before
stopping into the wamn
Nexex unplug your dehumidifier by pulling
on the power cord. Always grip plug firmly and pull straight out flom the receptacle.
Repair or replace immediately all eleca'ic service cords that have become flayed or otherxvise damaged. Do not use a cord
that shows cracks or abrasion damage along its length or at either rite plug or
connector end.
Turn the dehumidifier OFFand unplug it
before making any repairs or cleaning.
NOTE:V\:estrongly recommend that any
servicing be performed by a qualified indix idual.
For your safety, do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All dehumidifiers contain refligerants,
which under federal law must be remoxed prior m product disposal. If you are getting
rid of an old product with refrigerants, check with the company handling disposal
about what to do.
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
For personal safe_ this appliance must be properly grounded.
The power cord of dfis appliance is equipped
with a 3q)rong (gTounding) plug which mates with a standard 3-prong (grounding) wall
outlet m minimize the possibility of electric shock hazard flom this appliance.
Haxe the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
2
Where a 9-prong wall outlet is encounmred, it is your personal responsibility and obligation to haxe it replaced xvith a properly gTounded 3-piong wall outlet.
The dehumidifier should always be plugged into its own individual electrical oudet, which has a x_ltage rating matching the rating plato.
This provides the best performance and also prexents oxerloading house wiring circuits,
which cou]d cause a fire hazard flom
oxeflteated wires.
USEOFEXTENSIONCORDS
GEAppl_nce_com
Because of potential safety hazards under certain conditions, we strongly recommend
against the use of an extension cord.
USEOFADAPTERPLUGS
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
However, if you must use an adapter,
where local codes permit, a temporary
connection may be made to a properly
grounded 2-i)rong wall outlet by use of a Ui,-lismd adapter available at most
local hardware stores.
Tlle larger slot in tlle adapter must be aligned with tile larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
However, if you must rise an extension cord, it is absolutely necessary that it be
a Ui,-listed, 14 gauge, 3-wire grounding type appliance extension cord having a
grounding type plug and outlet and that tile electrical rating of the cord be
15 amperes (minimum) and 195 volts.
When disconnecung the power cord flom the adapter, always hold tile adaptor in place with one hand while pulling the power cord plug with tile other hand. If this is not done, tile adaptor ground mrmina] is very likely to break with repeated use.
If tile adapter ground terminal 1)teaks, DO NOT USE tile dehumidifier until a proper ground has been established.
Attaching the adapter ground terminal to a waft outlet cover screw doesnot ground the appfiance
unless the coverscrew is metal, not insulated, and the wall outlet is grounded threugh the house wiring.
Youshould have the circuit checkedby a qualified electrician to make sure theoutlet is properly grounded.
READANDFOLLOWTHISSAFETYINFORMATIONCAREFULLY. SAVETHESEINSTRUCTIONS
Aboutthe controlsonthe dehumidifier.
jO
BUCKET
FULL
POWER Pad
Controls0
Press to turn the delmmidifier on and off.
HUMIDITY CONTROLPads
@
The lmmidiq' level can be set within a range
of 35% RH (Relative Humidity) to 70% RH
(Relative Humidity) in 5% increments.
For drier ai_; press the pad and set to a lower percent ',_llue (%).
D)r damper ai_; press the pad and set to a higher percent wflue (%),
When you fit_t use the dehumidifier, set the humidity control to 45% or 50%. Allow at
least 24 hou_ fi)r the dehumidifier to achieve the humidity' level. If you still have
damper air than desired, set the humidity level to a lower setting,
HIGH
LOW
POWER
O FAN SPEEDPad
()mtrols the lira speed.
Press to set to HIGHor LOWfim speed.
Set the fan control to HlGHfor m'a_mum
moisture remowfl, X*\]_en the humidity has been reduced and quiet operation is
preferred, set the thn control to LOW.
O HUMIDITY LEVELDISPLAY
Displays percent humidit,_ lexel. Its accuracy is (+/- 5%).
O BUCKETFULLLED
Indicates presence of bucket and its fill level,
OtherFeatures
BUCKETFULLLight
Glows when the bucket is read)' to be emptied, or when the btlcket is removed or not replaced
in the l)r(>per position.
Auto Shut Off
The Water I,e\'el Control Switch shuts oft the dehumidifier when the bucket is fifll, or when
the bucket is removed or not replaced in the proper position. _Mso, when the bucket is out
of position, the unit will beep 3 times.
Auto Defrost
X._]_en fi'ost builds up on the cooling coils,
the compressor will wcle off until the fl'ost disappears. The lira continues to run.
4
PowerOutage
If a I)ower outage occurred or if the unit was
unI)lugged, the unit will display its prh)r setting. Note: If 0N is in the displa 5 the dehumidifier is
operating contintlOtlsl 5 but a specific humidity level is not set. You will need to reset the
HUMIOIrI'CONrBOL t(> the desired level.
Auto Restart
Once power is restored after a power outage, the unit automatically resumes operation atter
a 2 minute delay:
Loading...
+ 8 hidden pages