GE AFQ08 Owner’s Manual & Installation Instructions

AFQ08
Safety Instructions . . . . . . . .2, 3

Operating Instructions

Controls . . . . . . . . . . . . . . . . .4, 5

Care and Cleaning

Air Filter . . . . . . . . . . . . . . . . . .6
Grille and Case . . . . . . . . . . . . .6
Outdoor Coils . . . . . . . . . . . . . .6
Troubleshooting Tips . . . . . . .15
Normal Operating Sounds . . .16

Consumer Support

Consumer Support . . . . . . . . .20
Product Registration . . . . .17, 18
Warranty . . . . . . . . . . . . . . . . .19
TINSC2317C2R0 49-7486 02-04 JR
Owner’s Manual and
Installation Instructions
Write the model and serial numbers here:
Model # __________________________
Serial # __________________________
Find these numbers on a label on the side of the air conditioner.
Air Conditioners
Room
www.GEAppliances.com
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
Use this appliance only for its intended
purpose as described in this Owner’s Manual.
This air conditioner must be properly
installed in accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by
pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Repair or replace immediately all electric
service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
Turn the mode control to OFF and unplug
your air conditioner before making any repairs or cleaning.
NOTE: We strongly recommend that any
servicing be performed by a qualified individual.
For your safety…do not store or use
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
SAFETY PRECAUTIONS
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
HOW TO CONNECT ELECTRICITY
Consumer Support

Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions

2
3
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
WARNING!
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the 230/208 volt models.
USE OF EXTENSION CORDS—115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.
USE OF ADAPTER PLUGS—115-Volt models only
www.GEAppliances.com
SAVE THESE INSTRUCTIONS
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
4
About the controls on the air conditioner.
Features and appearance will vary.
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
To ensure proper operation, aim the remote
control at the signal receiver on the air conditioner.
The remote control signal has a range of
up to 21 feet.
Make sure nothing is between the air conditioner
and the remote control that could block the signal.
Make sure batteries are fresh and installed
correctly—see the Care and Cleaning section.
ON/OFF
Turns air conditioner on and off.
Display
MODE
Use to set the air conditioner to COOL, DEHUM (Dehumidification) or FAN mode.
Increase /Decrease Pads
Use to set temperature when in COOL mode.
FAN
Use to set the fan speed at HIGH (F3), MED (F2) or LOW (F1).
AUTO ON/OFF
ON—When the air conditioner is off, it can be
set to automatically turn on in 1 to 24 hours at its previous setting. Each touch will set the time in hours.
OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours. Each touch will set the time in hours.
To cancel the timer, press the AUTO ON/OFF pad until the display shows 00.
Remote Control Signal Receiver
Remote Control
TEMP MODE
POWER
ON/OFF
AUTO
ON/OFF
FAN
Dehum mode on
Cool mode on
Fan mode on
AUTO ON/OFF timer set on
F1 LOW F2 MED F3 HIGH
Air Conditioner Controls Remote Control
5
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
www.GEAppliances.com
When the air conditioner is turned on, it will automatically start in the setting last used, except the timer will be cancelled if it was set.
Lights on the air conditioner control panel indicate the selected settings.
Use the COOL mode with HIGH (F3), MED (F2) or LOW (F1) fan for cooling. Use the Increase / Decrease
pads to set the desired temperature between 60°F and 86°F in 1°F increments.
A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the COOL mode and HIGH (F3), MED (F2) or LOW (F1) fan with a middle set
temperature.
For Maximum Cooling—Select the COOL mode and HIGH (F3) fan with a lower set temperature.
For Quieter & Nighttime Cooling—Select the COOL
mode and LOW (F1) fan with a middle set temperature.
COOL Mode
Use the FAN at HIGH (F3), MED (F2) or LOW (F1) to provide air circulation and filtering without cooling.
Since fan only settings do not provide cooling, a temperature setting will not be displayed.
FAN Mode
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
Air Direction – Up and Down
The side-to-side air direction is adjusted by moving the lever to the left or right.
Air Direction – Side-to-Side
DEHUM Mode—Dehumidification
Use the DEHUM mode to provide dehumidification only. The fan will run at a fixed speed at this setting, so a fan speed cannot be set. Keep windows and doors closed for the best dehumidifying effects.
Press the MODE pad until the DEHUM indicator
light is lit.
In the DEHUM mode, a set temperature will not be displayed.
6
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
Care and cleaning of the air conditioner.
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.

Grille and Case

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned, a service available through your GE service outlet.

Outdoor Coils

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.
NOTE: DO NOT put the filter in an automatic dishwasher.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will clog it and reduce performance.
To remove:
Using the tab, pull the filter to the right to remove.

Air Filter

BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions for future reference.
Skill level – Installation of this appliance requires basic mechanical skills.
Completion time – Approximately 1 hour
We recommend that two people install
this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
Installation
Air Conditioner
Instructions
Model AFQ08
Some models require a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
ELECTRICAL REQUIREMENTS
TOOLS YOU WILL NEED
7
Phillips head screwdriver
Adjustable wrench Ruler or tape measure
Pencil
Level
Scissors or knife
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
Type A (16)
Right
accordion
panel
Foam top
window gasket
Window sash seal
(thin, adhesive-backed)
Left
accordion
panel
Type B (9)
Top mounting rail
seal strip
Top mounting rail
Window
locking bracket
Sill support (2)
Nut (2)
Bolt (2)
8
Installation Instructions
PARTS INCLUDED
9
Installation Instructions
WINDOW REQUIREMENTS
These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
All supporting parts must be secured to firm wood, masonry or metal.
The electrical outlet must be within reach of the power cord.
1
151⁄2min.
241⁄2to 37
(With accordion panels)
17
3
4min.
(Without accordion panels)
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.
WOOD PIECES– WIDTH: 2 LENGTH: Long enough to fit inside the
window frame. THICKNESS: To determine the thickness,
place a piece of wood on the stool to make it 1/2higher than the top of the storm window frame.
Attach securely with nails or screws provided by the installer.
1/2″ higher than frame
Storm window frame
Wood
Stool
2
REMOVE THE AIR CONDITIONER FROM THE CASE
Remove and save the 2 screws from the lower sides of the front grille.
Using the tab, pull the filter to the right to remove.
Remove the front grille screw.
3
A
B
C
Grasp the lower corners of the grille while pressing in on the case sides with your finger tips. Pull out to release and lift it up.
NOTE: Do not pull the bottom edge toward you more than 3or you may damage the tabs of the grille.
Remove the screw from each side of the case. Keep them in a safe location.
Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case.
E
F
D
10
Installation Instructions
FRONT
FRONT
FRONT
FRONT
FRONT
FRONT
REMOVE THE SHIPPING PAD
Remove and discard the shipping pad next to the compressor.
4
Attach the top mounting rail onto the top of the case with 4 Type A screws.
B
Type A screws
11
Installation Instructions
Remove and discard the shipping pad
INSTALL THE TOP MOUNTING RAIL ONTO THE CASE
Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail.
5
A
Seal strip
Top mounting rail
Top mounting rail
Bottom
INSTALL THE SIDE ACCORDION PANELS
Slide the left and right accordion panels into the top and bottom mounting rails.
Attach the accordion panels to the case using 4 Type A screws on each side.
6
A
B
Type A screws
Top mounting rail
Bottom mounting rail
Accordion panel
PREPARE THE WINDOW
Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash.
7
Window
sash seal
12
Installation Instructions
BACK
INSIDE
Loading...