Find these numbers on a label on the side of
the air conditioner.
Air Conditioners
49-7743-1 11-15 GE
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
SAFETY INFORMATION
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety
messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”. These words are defined as:
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal
injury.
SAFETY PRECAUTIONS
Use this appliance only for its intended purpose as
described in this Owner’s Manual.
This air conditioner must be properly installed in
accordance with the Installation Instructions before it
is used.
Never unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and pull straight
out from the receptacle.
Replace immediately all electric service cords that
have become frayed or otherwise damaged. A
damaged power supply cord must be replaced
with a new power supply cord obtained from the
manufacturer and not repaired. Do not use a cord
that shows cracks or abrasion damage along its
length or at either the plug or connector end.
Turn the unit OFF and unplug your air conditioner
before cleaning.
GE does not support any servicing of the air
conditioner. We strongly recommend that you do not
attempt to service the air conditioner yourself.
For your safety…do not store or use combustible
materials, gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants, which under
federal law must be removed prior to product
disposal. If you are getting rid of an old product
with refrigerants, check with the company handling
disposal about what to do.
If the receptacle does not match the plug, the
receptacle must be changed out by a qualified
electrician.
These R410A air conditioning systems require
contractors and technicians to use tools, equipment
and safety standards approved for use with this
refrigerant. DO NOT use equipment certified for
R22 refrigerant only.
2
WARNING
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord. For personal safety,
this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall outlet to minimize the
possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case. The
device should be tested on a periodic basis by first
pressing the TEST button and then the RESET button
while plugged into the outlet. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a
qualified service technician.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its
own individual electrical outlet which has a voltage
rating that matches the rating plate.
This provides the best performance and also prevents
overloading house wiring circuits which could cause a
fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements
section for specific electrical connection requirements.
• DO NOT use an extension cord with this Window Air
Conditioner.
• DO NOT use surge protectors or multi-outlet adaptors
with this Window Air Conditioner.
READ AND FOLLOW THIS SAFETY INFORMATION
CAREFULLY
SAVE THESE INSTRUCTIONS
RECYCLING INFORMATION
For appliance recycling information please visit www.
geappliances.com/recycling.
.
3
About the controls on the air conditioner.
Features and appearance will vary.
MODE CONTROLTEMPERATURE CONTROL
Controls
Mode Control
High Cool and Low Cool provide cooling with different fan
speeds.
Fan settings provide air circulation and filtering without
cooling.
NOTE: If you move the mode control from a cool
setting to OFF or to a fan setting, wait at least
3 minutes before switching back to a cool setting.
Cooling Descriptions
)RU1RUPDO&RROLQJ³Select High Cool or Low Cool with the
TEMPERATURE control at midpoint.
For Maximum Cooling³6HOHFWHigh Cool with the
TEMPERATURE control at the highest number available on your
knob.
For Quieter and Nighttime Cooling³6HOHFWLow Cool with the
TEMPERATURE control at midpoint.
TEMP Control
The TEMP control is used to maintain the room temperature.
The compressor will cycle on and off to keep the room at the
same level of comfort. When you turn the knob to a higher
number, the indoor air will become cooler. Turn the knob to a
lower number and the indoor air will become warmer.
4
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing outdoor
conditions. It must not be used in freezing outdoor conditions.
Remote Control
To ensure proper operation, aim the remote control at the
signal receiver on the air conditioner.
Make sure nothing is between the air conditioner and the
remote control that could block the signal.
Air Direction
Use the lever to adjust the air direction left and right only.
The remote control signal has a range of
up to 20 feet.
Make sure batteries are fresh and installed correctly as
indicated on the remote control.
Remote contains a magnet allowing it to attach to metal
surfaces.
5
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.