GE AEV05LVW1, AEV05LVQ2, AEV05LVL1 Owner’s Manual

Page 1
GEAppliances.com
Safety Instructions ............. 2, 3
Recycle Information ...................3
Operating Instructions
Controls ...........................4–6
Care and Cleaning
Air Filter ..............................7
Room
Outdoor Coils .........................7
Installation Instructions ...... 8-11
Troubleshooting Tips ............12
Consumer Support
Consumer Support ..........Back Cover
Warranty ............................13
Owner’s Manual and
Installation Instructions
AEV05
Acondicionador
de aire
Manual del propietario
y instrucciones de
instalación
La sección en español empieza en la página 14
Write the model and serial numbers here:
Model # _________________________
Serial # __________________________
Find these numbers on a label on the side of the air conditioner.
Air Conditioners
49-7743-1 11-15 GE
Page 2
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
SAFETY INFORMATION
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety
messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”. These words are defined as:
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
SAFETY PRECAUTIONS
 Use this appliance only for its intended purpose as
described in this Owner’s Manual.
 This air conditioner must be properly installed in
accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and pull straight out from the receptacle.
Replace immediately all electric service cords that
have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
 Turn the unit OFF and unplug your air conditioner
before cleaning.
 GE does not support any servicing of the air
conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
For your safety…do not store or use combustible
materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
 All air conditioners contain refrigerants, which under
federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
 If the receptacle does not match the plug, the
receptacle must be changed out by a qualified electrician.
 These R410A air conditioning systems require
contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only.
2
Page 3
WARNING
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
DO NOT use an extension cord with this Window Air Conditioner.
DO NOT use surge protectors or multi-outlet adaptors with this Window Air Conditioner.
READ AND FOLLOW THIS SAFETY INFORMATION
CAREFULLY
SAVE THESE INSTRUCTIONS
RECYCLING INFORMATION
For appliance recycling information please visit www. geappliances.com/recycling.
.
3
Page 4
About the controls on the air conditioner.
Features and appearance will vary.
MODE CONTROL TEMPERATURE CONTROL
Controls
Mode Control
High Cool and Low Cool provide cooling with different fan speeds.
Fan settings provide air circulation and filtering without cooling.
NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.
Cooling Descriptions
)RU1RUPDO&RROLQJ³Select High Cool or Low Cool with the TEMPERATURE control at midpoint.
For Maximum Cooling³6HOHFWHigh Cool with the TEMPERATURE control at the highest number available on your knob.
For Quieter and Nighttime Cooling³6HOHFWLow Cool with the TEMPERATURE control at midpoint.
TEMP Control
The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
4
Page 5
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.
Remote Control
 To ensure proper operation, aim the remote control at the
signal receiver on the air conditioner.
 Make sure nothing is between the air conditioner and the
remote control that could block the signal.
Air Direction
Use the lever to adjust the air direction left and right only.
 The remote control signal has a range of
up to 20 feet.
 Make sure batteries are fresh and installed correctly as
indicated on the remote control.
 Remote contains a magnet allowing it to attach to metal
surfaces.
5
Page 6
Care and cleaning of the air conditioner.
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Air Filter
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Pull the tab on the right side of the unit until the filter is out.
To remove:
Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
CAUTION: DO NOT operate the air conditioner without
a filter because dirt and lint will clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.
How to Insert the Batteries in the Remote Control
Remove the battery cover by sliding it according to the arrow
1
direction.
Insert new batteries, making sure that the (+) and (–) of
2
battery are installed correctly.
Reattach the cover by sliding it back
3
into position.
Tab
NOTES:
 Use 2 “AAA” (1.5 volt) alkaline batteries. Do not use
rechargeable batteries.
 Remove the batteries from the remote control if the system is
not going to be used for a long time.
 Do not mix old and new batteries. Do not mix alkaline,
standard (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc) batteries.
Tab
6
Page 7
Installation
Air Conditioner
Instructions
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT ³ Save these instructions
for local inspector’s use.
IMPORTANT ³ Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions for
future reference.
Skill level – Installation of this appliance requires
basic mechanical skills.
Completion time –
• We recommend that two people install this product.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not covered under the Warranty.
• You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
Approximately 1 hour
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special
SUREOHPV³FRQVXOWDTXDOLILHGHOHFWULFLDQ
TOOLS YOU WILL NEED
Phillips head screwdriver
Flat-blade screwdriver
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt AC,
60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt AC,
protected with a time-delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Ruler or tape measurePencil
Level
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the
RESET button while plugged into the outlet. If the TEST button does not trip or
if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
7
Scissors or knife
Page 8
Installation Instructions
PARTS INCLUDED
(Appearance may vary)
Top mounting rail
Air
conditioner
Window
sash seal
Foam top window
gasket
Right
accordion
panel
Left
accordion
panel
Type A (4) Type B (6)
Top mounting rail
seal strip
Window locking
bracket (1)
8
Page 9
Installation Instructions
WINDOW REQUIREMENTS
1
• These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
• The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
• All supporting parts must be secured to firm wood, masonry or metal.
• The electrical outlet must be within reach of the power cord.
• Follow the dimensions in the table and illustration for your model.
Models A B
AET05, AEY05 12 1/2smin. 23s–38s AEW05, AEZ05 AEW06, AEZ06 13 1/2smin. 22 1/2s–38s AEW08, AEZ08
A
B
(With accordion panels)
ATTACH THE TOP MOUNTING RAIL
3
SEAL STRIP
(Some models may have the seal strip already attached to the top mounting rail. If applicable, skip this step.)
Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top mounting rail, along the front edge.
Top mounting rail
Remove backing from seal strip
FRONT VIEW
Seal strip
Top mounting rail
STORM WINDOW REQUIREMENTS
2
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.
WOOD PIECES WIDTH: 2s LENGTH: Long enough to fit inside the window
frame. THICKNESS: To determine the thickness, place a
piece of wood on the sill to make it 1/2s higher than the top of the storm window frame or the vinyl frame.
Attach securely with nails or screws provided by the installer.
1/2shigher than vinyl frame (on some windows)
1/2shigher than storm window frame
Storm window frame
Sill
Vinyl frame
Wood
4
PREPARE THE AIR CONDITIONER
Install the top mounting rail with 4 Type A
A
screws from the outside of the case.
Top mounting rail
Bottom mounting rail
Hold the accordion panel in one hand and
B
gently pull back to free the open end.
9
Page 10
Installation Instructions
PREPARE THE AIR CONDITIONER
4
(cont.)
Slide the free end of the accordion panel into
C
the side panel rails. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
NOTE: There is a right and a left accordion panel. Be sure to use the proper panel for each side.
Slide the left and right accordion panels into
D
the top and bottom mounting rails.
INSTALL THE AIR CONDITIONER IN
6
THE WINDOW
A
Place the air conditioner on the sill with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the outside. Use a level; about a 1/3 bubble will be the correct case slant to the outside.
or
Type B screws
B
Extend the left and right accordion panels to the vertical window sashes and attach, through the holes in the panels, with 5 Type B screws, as appropriate.
or
Top left
Bottom mounting rail
PREPARE THE WINDOW
5
Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.
Top mounting rail
Top right
INSTALL SUPPORT BRACKET AND
7
FOAM TOP WINDOW GASKET
A
B
C
CAUTION:
To prevent broken glass or damage to windows, on vinyl or other similarly constructed windows, attach the window locking bracket to the window side jamb with one Type B screw.
Cut the foam top window gasket to the window width.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room. NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
Vinyl
Wood
10
Page 11
Troubleshooting Tips.
Problem Possible Causes What To Do
Air conditioner The air conditioner Make sure the air conditioner plug is pushed does not start is unplugged. completely into the outlet.
The fuse is blown/circuit Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
Power failure. The unit will automatically restart in the settings last used after the power is restored.
There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.
The current interrupter Press the RESET button located on the power cord plug.
use of the air conditioner and contact a qualified service technician.
Air conditioner does Airflow is restricted. Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.
The temp control may On models with touch pads: In the Cool mode, press the not be set correctly. Decrease
• On models with control knobs, turn the temperature knob to a higher number.
The air filter is dirty. Clean the filter at least every 30 days. See the Care and Cleaning section.
The room may have been hot. When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping. Check for open furnace registers and cold air returns. Cooling coils have iced up. See “Air conditioner freezing up” below.
device is tripped.
If the RESET button will not stay engaged, discontinue
pad.
Air conditioner Ice blocks the air flow On models with control knobs, set the mode control at freezing up and stops the air conditioner High Fan or High Cool with the Temp at 1 or 2.
or High Cool and set the thermostat to a higher temperature.
The remote control The batteries are inserted Check the position of the batteries. They should be is not working incorrectly. inserted in the opposite (+) and (–) direction.
The batteries may be dead. Replace the batteries.
Water drips outside Hot, humid weather. This is normal.
Water drips indoors The air conditioner is not For proper water disposal, make sure the air conditioner
tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture removed from air This is normal for a short period in areas with little base pan and drains into base pan. humidity; normal for a longer period in very humid areas.
from cooling the room.
• On models with touch pads, set the controls at High Fan
Normal Operating Sounds
 You may hear a pinging noise caused by water being
picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
 You may hear the thermostat click when the
compressor cycles on and off.
 Water will collect in the base pan during
high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
 The fan may run even when the compressor
does not.
11
Page 12
Notes.
12
Page 13
*($LU&RQGLWLRQHU³2QH<HDU/LPLWHG:DUUDQW\(For customers in the U.S.A.
Staple your receipt here. Proof of the original purchase date is needed to make a warranty claim.
For The Period Of: We Will Replace:
One Year Replacement unit for any product which fails due to a defect in materials or workmanship.
From the date of the The replacement unit is warranted for the remainder of your product’s original one-year original purchase warranty period.
In Order to Make a Warranty Claim:
)
Properly pack your unit. We recommend using the original
carton and packing materials.
Return the product to the retail location where it
was purchased.
Include in the package a copy of the sales receipt or other
evidence of date of original purchase. Also print your name and address and a description of the defect.
What Is Not Covered:
Customer instruction. This owner’s manual provides
information regarding operating instructions and user controls.
Improper installation, delivery or maintenance. If you have an
installation problem, or if the air conditioner is of improper cooling capacity, contact your dealer or installer.
<RXDUHUHVSRQVLEOHIRUSURYLGLQJDGHTXDWHHOHFWULFDO
plumbing and other connecting facilities.
Failure of the product resulting from modifications to
the product or due to unreasonable use, including failure to provide reasonable and necessary maintenance.
(;&/86,212),03/,(':$55$17,(6³<RXUVROHDQGH[FOXVLYHUHPHG\LVSURGXFWUHSODFHPHQWDVSURYLGHGLQ
this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
Replacement of house fuses or resetting of circuit breakers.Failure due to corrosion on models not corrosion-protected.Damage to the product caused by improper power supply
voltage, accident, fire, floods or acts of God.
,QFLGHQWDORUFRQVHTXHQWLDOGDPDJHFDXVHGE\SRVVLEOH
defects with this air conditioner.
Damage caused after delivery.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties, whether express, oral or statutory which extend beyond the description on the face hereof, including specifically the implied warranties of merchantability or fitness for a particular purpose.
Warrantor: General Electric Company. Louisville, KY 40225
13
Page 14
Consumer Support.
GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, or even order parts on-line. In Canada: www.GEAppliances.ca
In the U.S.A.: GEAppliances.com
Real Life Design Studio In the U.S.A.: GEAppliances.com
*(VXSSRUWVWKH8QLYHUVDO'HVLJQFRQFHSW³SURGXFWVVHUYLFHVDQGHQYLURQPHQWVWKDWFDQEHXVHGE\ people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).
In Canada, contact: Manager, Consumer Relations, Mabe Canada Inc.
Suite 310, 1 Factory Lane Moncton, N.B. E1C 9M3
Parts and Accessories In the U.S.A.: GEAppliances.com
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. GE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
Customers in Canada should consult the yellow pages for the nearest Mabe service center, or call 1.800.561.3344.
Contact Us In the U.S.A.: GEAppliances.com
If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations
GE Appliances, Appliance Park Louisville, KY 40225
In Canada: www.GEAppliances.ca, or write to: Director, Consumer Relations, Mabe Canada Inc.
Suite 310, 1 Factory Lane Moncton, N.B. E1C 9M3
Printed in China
Loading...