GE AEM05*, AEM06*, AER08* Owner’s Manual & Installation Instructions

GEAppliances.com
Safety Instructions ............. 2, 3
Operating Instructions
Controls ...........................4–6
Care and Cleaning
Air Filter ..............................6
Outdoor Coils .........................6
Room
Installation Instructions ......7–10
Troubleshooting Tips ............11
Consumer Support
Consumer Support ..........Back Cover
Warranty ............................12
Owner’s Manual and
Installation Instructions
AEM05* AEM06* AER08*
Climatiseur
Manuel d’utilisation et
instructions d’installation
La section française commence à la page 13
Acondicionador
de aire
*ENERGY STAR® labeled product
As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.
Write the model and serial numbers here:
Model # _________________________
Serial # __________________________
Find these numbers on a label on the side of the air conditioner.
Air Conditioners
Manual del propietario
y instrucciones de
instalación
La sección en español empieza en la página 27
49-7746 12-14 GE
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
SAFETY PRECAUTIONS
Use this appliance only for its intended
purpose as described in this Owner’s Manual.
This air conditioner must be properly
installed in accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Replace immediately all electric service
cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
Turn the unit OFF and unplug your air
conditioner before cleaning.
 GE does not support any servicing of the
air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
For your safety…do not store or use
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
 All air conditioners contain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
 If the receptacle does not match the plug,
the receptacle must be changed out by a qualified electrician.
 These R410A air conditioning systems
require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
2
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
GEAppliances.com
WARNING!
USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
DO NOT use an extension cord with this
Window Air Conditioner.
DO NOT use surge protectors or multi-outlet
adaptors with this Window Air Conditioner.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
3
About the controls on the air conditioner.
Features and appearance will vary. Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Light indicates the unit is in the temperature or delay time Set mode.
Light indicates the delay timer is set.
Power
On/Off
Auto High Med Low
Fan Mode
NOTE: The display always shows the room temperature except when setting the Set temperature or the Delay timer.
Cool Fan Only Energy Saver
Reset Filter
Set
Air Conditioner Controls
Controls (on some models)
Power Pad
Turns air conditioner on and off. When turned on, the display will show the room temperature.
Display
Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.
NOTE: The display will change to show the room temperature after settings have been made.
Temp Increase Ÿ /Decrease ź Pads
Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while
setting.
Delay Timer Increase Ÿ (+) /Decrease ź(–) Pads
Each touch of the Increase Ÿ/ Decreaseź pads on the unit or the Increase + / Decrease pads on the remote control will set the delay time when using the Delay 1–24hr
Set light will turn on while setting.
Fan Speed Pads
Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + /
Decrease pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto
fan on.
+
-
Delay
1-24 Hrs
8
timer. The
Delay 1–24hr
Delay timer Decrease
Mode select
Fan speed Decrease
Temperature set Increase and Decrease
Fan Fan
Remote Control
Mode Pad
Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.
Delay Pads/Delay 1-24hr Pad
Delay ON³:KHQWKHDLUFRQGLWLRQHULVRIILWFDQ
be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.
Delay OFF³:KHQWKHDLUFRQGLWLRQHULVRQ it can be set to automatically turn off in 1 to 24 hours.
How to set: Press the Delay 1–24hr pad on the unit or the
Delay pad on the remote control. Each touch
of the Increase Ÿ / Decrease źpads on the unit or the Increase + / Decrease pads on the remote control will set the timer in 1-hour intervals. The Set light will turn on while setting.
To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or the Delay pad on the remote control. Use the Increase Ÿ/ Decreaseźpads on the unit or the Increase remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.
Reset Filter
LED will turn on when fan has accumulated 250 hours of run time as a reminder to clean filter. Press Reset Filter to turn off the LED and reset the accumulated run time.
+ / Decrease pads on the
Delay timer Increase
Auto Fan on
Fan speed Increase
Unit power on/off
Note: The default temperature reading on the display is degree Fahrenheit ( °F). To change the display to degree Celcius (°C), press the Temp Increase Ÿ and Temp Decrease ź buttons together and hold for 3
4
seconds. Repeat the process to change back to degree Fahrenheit (°F)
GEAppliances.com
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in
Remote Control
 To ensure proper operation, aim the remote
control at the signal receiver on the air conditioner.
 Make sure nothing is between the air conditioner
and the remote control that could block the signal.
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase Ÿ / Decrease ź pads to set the desired temperature
between 64°F and 86°F in 1°F increments. An electronic thermostat is used to maintain the room
temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting
freezing outdoor conditions.
 The remote control signal has a range of
up to 20 feet.
 Make sure batteries are fresh and installed
correctly as indicated on the remote control.
 Remote contains a magnet allowing it to attach
to metal surfaces.
to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling³6HOHFWWKHCool mode and High or Med fan with a middle set temperature.
For Maximum Cooling³6HOHFWWKHCool mode and High fan with a lower set temperature.
For Quieter and Nighttime Cooling³6HOHFWWKH Cool mode and Low fan with a middle set
temperature.
Energy Saver Mode
This mode optimizes the cooling power of your air conditioner, thereby saving you energy. Once the set point temperature has been reached, the fan will cycle off to save energy. The fan will cycle back on periodically to insure all cooling capacity in the system is used. This mode is the default mode for the unit. Each time the unit is powered off, it will restart in Energy Saver mode ON. This includes Delay timer mode. The first time the unit is turned on, the settings will be 70° and Low fan. You can adjust the fan speed and temperature to your personal comfort.
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.
Auto Fan Speed
Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.
Energy Saver ON³Helps minimize electricity use. It is normal for the fan to cycle off and then back on in this mode. This on/off cycle can repeat multiple times. Because the fan will cycle off, you may notice a variation in room temperature and humidity.
Energy Saver OFF³When this mode is not engaged, the fan will run continuously, and in Cool mode the compressor will cycle on and off to maintain room temperature.
NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.
NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.
Power Outage Recovery Feature
In the case of a power outage or interruption, the unit will automatically restart in the settings last used after the power is restored. If the Delay 1–24hr
feature was set, it will resume countdown. You may need to set a new time if desired.
5
About the controls on the air conditioner. GEAppliances.com
Additional important information.
Air Direction
Use the lever to adjust the air direction left and right only.
Care and cleaning of the air conditioner.
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
Air Filter
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
To remove:
Pull the tab on the right side of the unit until the filter is out.
To remove:
Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.
Tab
Tab
How to Insert the Batteries in the Remote Control
Remove the battery cover by sliding it according
1
to the arrow direction.
Insert new batteries, making sure that the (+)
2
and (–) of battery are installed correctly.
Reattach the cover by sliding it back
3
into position.
6
NOTES:
 Use 2 “AAA” (1.5 volt) alkaline batteries. Do not
use rechargeable batteries.
 Remove the batteries from the remote control if
the system is not going to be used for a long time.
 Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc) batteries.
Installation
Air Conditioner
Instructions
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT ³ Save these instructions
for local inspector’s use.
IMPORTANT ³ Observe all governing
codes and ordinances.

Note to Installer – Be sure to leave these
instructions with the Consumer.
 Note to Consumer – Keep these instructions for
future reference.
 Skill level – Installation of this appliance requires
basic mechanical skills.
 Completion time –  :HUHFRPPHQGWKDWWZRSHRSOHLQVWDOOWKLV
product.
 3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKH
installer.
 3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW
covered under the Warranty.
 <RX0867XVHDOOVXSSOLHGSDUWVDQGXVHSURSHU
installation procedures as described in these instructions when installing this air conditioner.
Approximately 1 hour
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special
SUREOHPV³FRQVXOWDTXDOLILHGHOHFWULFLDQ
TOOLS YOU WILL NEED
Phillips head screwdriver
Flat-blade screwdriver
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt AC,
60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt AC,
protected with a time-delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Ruler or tape measurePencil
Level
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the
RESET button while plugged into the outlet. If the TEST button does not trip or
if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
7
Scissors or knife
Installation Instructions
PARTS INCLUDED
(Appearance may vary)
Top mounting rail
Air
conditioner
Window
sash seal
Foam top window
gasket
Right
accordion
panel
Left
accordion
panel
Type A (4) Type B (6)
Top mounting rail
seal strip
Window locking
bracket (1)
8
Installation Instructions
WINDOW REQUIREMENTS
1
These instructions are for a standard double-hung
window. You will need to modify them for other types of windows.
The air conditioner can be installed without the
accordion panels if needed to fit in a narrow window. See the window opening dimensions.
All supporting parts must be secured
to firm wood, masonry or metal.
The electrical outlet must be within reach of the
power cord.
Follow the dimensions in the table and illustration
for your model.
Models A B
AEL06 13 1/2smin. 22 1/2s–38s AEL08
A
B
(With accordion panels)
ATTACH THE TOP MOUNTING RAIL
3
SEAL STRIP
(Some models may have the seal strip already attached to the top mounting rail. If applicable, skip this step.)
Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top mounting rail, along the front edge.
Top mounting rail
Remove backing from seal strip
FRONT VIEW
Top mounting rail
STORM WINDOW REQUIREMENTS
2
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.
WOOD PIECES WIDTH: 2s LENGTH: Long enough to fit inside the window
frame. THICKNESS: To determine the thickness, place a
piece of wood on the sill to make it 1/2s higher than the top of the storm window frame or the vinyl frame.
Attach securely with nails or screws provided by the installer.
1/2shigher than vinyl frame (on some windows)
1/2shigher than storm window frame
Storm window frame
Sill
Vinyl frame
Wood
Seal strip
4
PREPARE THE AIR CONDITIONER
Install the top mounting rail with 4 Type A
A
screws from the outside of the case.
Top mounting rail
Bottom mounting rail
Hold the accordion panel in one hand and
B
gently pull back to free the open end.
9
Installation Instructions
PREPARE THE AIR CONDITIONER
4
(cont.)
Slide the free end of the accordion panel into
C
the side panel rails. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
NOTE: There is a right and a left accordion panel. Be sure to use the proper panel for each side.
Slide the left and right accordion panels into
D
the top and bottom mounting rails.
INSTALL THE AIR CONDITIONER IN
6
THE WINDOW
A
Place the air conditioner on the sill with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the outside. Use a level; about a 1/3 bubble will be the correct case slant to the outside.
or
Type B screws
B
Extend the left and right accordion panels to the vertical window sashes and attach, through the holes in the panels, with 5 Type B screws, as appropriate.
or
Top left
Bottom mounting rail
PREPARE THE WINDOW
5
Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.
Top mounting rail
Top right
INSTALL SUPPORT BRACKET AND
7
FOAM TOP WINDOW GASKET
A
B
C
CAUTION:
To prevent broken glass or damage to windows, on vinyl or other similarly constructed windows, attach the window locking bracket to the window side jamb with one Type B screw.
Cut the foam top window gasket to the window width.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room. NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
Vinyl
Wood
10
Troubleshooting Tips.
GEAppliances.com
Problem Possible Causes What To Do
Air conditioner The air conditioner Make sure the air conditioner plug is pushed does not start is unplugged. completely into the outlet.
The fuse is blown/circuit Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
Power failure. The unit will automatically restart in the settings last used after the power is restored.
There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.
The current interrupter Press the RESET button located on the power cord plug.
use of the air conditioner and contact a qualified service technician.
Air conditioner does Airflow is restricted. Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.
The temp control may On models with touch pads: In the Cool mode, press the not be set correctly. Decrease ź pad.
2QPRGHOVZLWKFRQWURONQREVWXUQWKHWHPSHUDWXUH knob to a higher number.
The air filter is dirty. Clean the filter at least every 30 days. See the Care and Cleaning section.
The room may have been hot. When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping. Check for open furnace registers and cold air returns. Cooling coils have iced up. See “Air conditioner freezing up” below.
device is tripped.
If the RESET button will not stay engaged, discontinue
Air conditioner Ice blocks the air flow On models with control knobs, set the mode control at freezing up and stops the air conditioner
or High Cool and set the thermostat to a higher temperature.
The remote control The batteries are inserted Check the position of the batteries. They should be is not working incorrectly. inserted in the opposite (+) and (–) direction.
The batteries may be dead. Replace the batteries.
Water drips outside Hot, humid weather. This is normal.
Water drips indoors The air conditioner is not For proper water disposal, make sure the air conditioner
tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture removed from air This is normal for a short period in areas with little base pan and drains into base pan. humidity; normal for a longer period in very humid areas.
from cooling the room.
High Fan or High Cool with the Temp at 1 or 2.
2QPRGHOVZLWKWRXFKSDGVVHWWKHFRQWUROVDW High Fan
Normal Operating Sounds
 You may hear a pinging noise caused by
water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
 You may hear the thermostat click when the
compressor cycles on and off.
 Water will collect in the base pan during
high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
 The fan may run even when the compressor
does not.
11
*($LU&RQGLWLRQHU³2QH<HDU/LPLWHG:DUUDQW\
All warranty service provided by our Factory Service Centers,
®
or an authorized Customer Care
technician. To schedule service, visit us on-line at ge.com, or call 800.GE.CARES (800.432.2737). Have serial number and model number available when calling
Staple your receipt here.
Proof of the original purchase
date is needed to obtain service
under the warranty.
for service.
For The Period Of: GE Will Replace:
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship.
From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.
What Is Not Covered:
Service trips to your home to teach you how to
use the product.
Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible
IRUSURYLGLQJDGHTXDWHHOHFWULFDOFRQQHFWLQJIDFLOLWLHV
Failure of the product resulting from modifications to
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
In commercial locations, labor necessary to move the
unit to a location where it is accessible for service by an individual technician.
Replacement of house fuses or resetting of circuit
breakers.
Failure due to corrosion on models not corrosion-
protected.
Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
,QFLGHQWDORUFRQVHTXHQWLDOGDPDJHFDXVHGE\SRVVLEOH
defects with this air conditioner.
Damage caused after delivery.
(;&/86,212),03/,(':$55$17,(6³<RXUVROHDQGH[FOXVLYHUHPHG\LVSURGXFWUHSDLUDVSURYLGHGLQ
this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor: General Electric Company. Louisville, KY 40225
12
Loading...
+ 28 hidden pages