RAVRMS (AZ Series*—7500)
Wall-Mounted Room Air Sensor
• Wall-mounted room air sensor provides Temperature
Limiting and Freeze Sentinel™ capability.
• Includes 3-meter conductor wire for hook-up to
Vertical Zoneline.
• Required for Motion Sensor/Door Switch applications.
RAVWP6 (AZ Series*—7500)
Wall Plenum
• Wall Plenum for installation in walls less than 6" thick.
• Wall Plenum 19-3/4" x 32".
• Wall cutout dimensions 20" x 32-1/4".
• Warm gray beige color.
RAVWP8 (AZ Series*—7500)
Wall Plenum
• Wall Plenum for installation in walls less than 8" thick.
• Wall Plenum 19-3/4" x 32".
• Wall cutout dimensions 20" x 32-1/4".
• Warm gray beige color.
RAVWP12 (AZ Series*—7500)
Wall Plenum
• Wall Plenum for installation in walls less than 12" thick.
• Wall Plenum 19-3/4" x 32".
• Wall cutout dimensions 20" x 32-1/4".
• Warm gray beige color.
* A-B Series: Zonelines® built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
3
5
Vertical Zoneline® units
RAVWP15 (AZ Series*—7500)
Wall Plenum
• Wall Plenum for installation in walls less than 15" thick.
• Wall Plenum 19-3/4" x 32".
• Wall cutout dimensions 20" x 32-1/4".
• Warm gray beige color.
RAVAL1 (AZ Series*—7500)
Aluminum Outdoor Grille
• Extruded Aluminum Outdoor Grille for installation
on RAVWP series wall plenums.
• Grille is 19-3/4" x 32" x 1-1/4".
• Mill finish.
RAVRG1 (AZ Series*—7500)
Access Panel with Return Air Grille
• Access Panel with Return Air Grille for installation
in closet wall.
• Allows access/removal of Vertical Zoneline for
cleaning or service.
• Outside dimensions 30" x 50".
• Wall cutout dimensions 28" x 48".
• Accepts 20" x 20" x 1" field-supplied filter.
• Warm gray beige color.
* A-B Series: Zonelines® built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
4
RAVRG2 (AZ Series*—7500)
Return Air Grille
• Return Air Grille for installation in common wall to closet.
• Exterior dimensions 22-1/2" x 22-1/2".
• Wall cutout dimension 20-3/8" x 20-3/8".
• Accepts 20" x 20" x 1" field-supplied filter.
• Warm gray beige color.
RAK5157/5207/5307†
(AZ Series*—2800, 3800, 5500, 5800 and 7500 only)
265/277-Volt Universal Power Supply Kit
• 9-pin connector with three 7" 12-gauge conductor wires.
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
† The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: All power cord kits and permanent connection
kits may be used on all units (of matching voltage). NOTE: 7,000 BTU models do not have 5,000 watt heaters.
5
7
Zoneline® units
6
Zoneline units
RAB71A (All Zoneline Series)
Standard Wall Case
The RAB71A is a galvanized steel wall sleeve with expanded
polystyrene foam insulation. It is welded and protected with
baked-on enamel. Welded areas are protected with a sealing
compound to prevent rust. The RAB71 wall case accepts all
Zoneline chassis models.
RAB77A4 (All Zoneline Series)
SMC Wall Case
The Zoneline SMC universally designed wall case by
GE utilizes a fiberglass-reinforced polyester compound to
produce a durable, non-corrosive wall case for all Zoneline
Packaged Terminal Air Conditioners and Heat Pumps. The
RAB77A4 SMC wall case accepts all Zoneline chassis models.
For more positive control of condensate water, the RAD10
drain kit routes condensate to the exterior or to the interior
of the building through the wall case. Suitable provision (field
applied) should be made to connect the RAD10 drain tube to
a drain system in the building. Drain tube assemblies are
1/2" O.D. copper and consist of a short right-angle tube and
a 6"-long straight tube to suit the particular application.
RAF452 (AZ Series*—2200, 3200 and 5200 only)
Replacement Standard Room Cabinet
Room cabinet with wrap-around design has attractive
textured finish which matches unit sleeve. Cabinet is
injection-molded of high-impact polystyrene. Cabinet fastens
to chassis without tools or hardware. The room cabinet
contains the slide-out filters and 2-position reversible
discharge louvers.
RAF452A (AZ Series*—2500, 3500 and 5500 only)
Replacement Standard Room Cabinet
Room cabinet with wrap-around design has attractive
textured finish which matches unit sleeve. Cabinet is injectionmolded of high-impact polystyrene. Cabinet fastens to chassis
without tools or hardware. The room cabinet contains the
slide-out filters and 2-position reversible discharge louvers.
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
7
9
Zoneline® unitsZonelineunits
RAF453 (AZ Series*—2800, 3800 and 5800 only)
Replacement Standard Room Cabinet
Room cabinet with wrap-around design has attractive
textured finish which matches unit sleeve. Cabinet is injectionmolded of high-impact polystyrene. Cabinet fastens to chassis
without tools or hardware. The room cabinet contains the
slide-out filters and 2-position reversible discharge louvers.
RAG60 (AZ Series*)
Stamped Aluminum Exterior Rear Grille
The standard exterior grille is made of durable aluminum to
protect chassis components and minimize air recirculation.
RAG61/62/63 (AZ Series*)
Architectural Rear Grille
Optional, one-piece molded grille and frame assembly for
improved appearance and protection. Grilles are molded of
GE Cycoloy® and have a slightly textured, colorfast surface to
blend with most walls.
RAG61/62/63
RAG61 – Beige, RAG62 – Maple, RAG63 – Dark Brown
RAG67 (AZ Series*)
Aluminum Architectural Outdoor Grille
• Extruded aluminum outdoor grille for use with RAB71, RAB77,
and extended wall cases.
• Grilles are paintable to match building décor.
RAKOIM (AZ Series*—2200, 3200 and 5200 only)
Optional Interface Module for Central Desk
Control or Remote Thermostat Control
The RAKOIM is required if a unit is to be installed with a Central
Desk Control or a Remote Thermostat Control. Includes screw,
and a short wire harness on the RAKOIM that is plugged into
the mating receptacle on the front of the control box.
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
8
RAK40 (AZ Series*)
Air Deflector Kit
Kit adapts AZ chassis for use with older GE architectural grilles.
The aluminum deflectors are installed to the condenser end
sheet flanges to prevent condenser airflow recirculation. The kit
also allows some custom (non-standard) rear grilles to be used,
provided they have sufficient open area.
7-3/32"
6-1/2"
7-3/32"
6-1/2"
RAK605 (AZ Series*—2100 and 3100 only)
Duct Adapter
(Not for 2600 and 5100 Series)
The RAK605 duct adapter is attached to the top of the wall case
to allow the air from the Zoneline to heat or cool an adjacent
room. Duct extension RAK601 can be applied to right or left of
the adapter. (Zoneline 5100 Series not approved for ducted
application).
RAK6052 (AZ Series*—2200, 2500, 2800, 3200, 3500,
and 3800 only)
Duct Adapter
(Not for 5200, 5500 or 5800 Series)
The RAK6052 duct adapter is attached to the top of the wall case
to allow the air from the Zoneline to heat or cool an adjacent
room. Duct extension RAK601 can be applied to right or left of
the adapter. (Zoneline 5200 and 5500 Series not approved for
ducted application).
RAK601/602 (AZC and AZ Series*—2100, 2200, 2500,
2800, 3100, 3200, 3500 and 3800 only)
Duct Extension, Register and Trim Flange
RAK601 is a 44"-long duct and includes an air register and trim
flange for the secondary space. If two extensions are made
from one RAK601 duct, an additional air register and trim flange
can be ordered separately as an RAK602–reducing the cost of
the installation. For use with RAK605 and RAK6052.
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
9
11
Zoneline® units
8-3/8"
6-1/2"
RAK7012 (AZ Series*—2200, 2500, 3200, 3500,
2800 and 3800 only)
Duct Adapter for Replacement of
A-B with Rounded Front AZ Chassis
The RAK7012 duct adapter is designed to line up with the duct
extension where the original chassis was a flat-top discharge
A-B Series. Using the RAK7012 will allow the existing duct
extension to be used without requiring the relocation of the hole
through the wall to the adjacent room. Discharge grille, end
plate, and extension mounting hardware must be removed from
old duct adapter and installed on the RAK7012.
RAK702 (AZ Series*—2100 and 3100 only)
Duct Transition for Replacement of
AZC with Sloped Front AZ Chassis
The RAK702 duct transition is designed to allow duct installation
where the original chassis was a slope front discharge (AZC or
AZR) chassis. Using the RAK702 will allow the existing duct
adapter and extension to be used without requiring the
relocation of the hole through the wall to the adjacent room.
RAK7022 (AZ Series*—2200, 2500, 2800, 3200,
3500 and 3800 only)
Duct Transition for Replacement
of AZC with Rounded Front AZ Chassis
The RAK7022 duct transition is designed to allow duct installation where
the original chassis was a slope front discharge (AZC/AZR/AZ21/AZ31)
chassis. Using the RAK7022 will allow the existing duct adapter and
extension to be used without requiring the relocation of the hole through
the wall to the adjacent room.
RAK201 (AZC and AZ Series*)
Access Plate Cover
The RAK201 access plate cover is made of heavy-gauge steel
with multiple knockouts for special applications. Will adapt to
service conduit .875" or 1.125"; circuit breaker up to 30 amp or
30 amp receptacle. The RAK201 fits old sub-bases RAK120,
RAK121 and RAK122 for easy replacement of A-B series with
AZC and AZ series.
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
10
Zoneline units
Chaseway
Power cord and junction box
not included with sub-base.
Chaseway
RAK204 (AZ Series*—2200, 2500, 3200 and 3500 only)
Standard Sub-Base
The RAK204 sub-base is made of heavy-gauge steel to provide support of the
wall case. It has full base enclosure with break-away side channels, simple
connection to wall case, and 4-point leveling legs. The sub-base will adapt to
service conduit, circuit breakers and receptacles up to 30 amps. It may also be
used as a non-electrical sub-base to provide support for the unit.
Circuit
Kit No. Sub-Base Ampacity Chaseway Power Cord
RAK204U** Standard N/A Not Included Not Included
RAK204D20 Sub-Base 230/208V 15 & 20 Included Not Included
RAK204D30 Sub-Base 230/208V 30 Included Not Included
RAK204E15 Sub-Base 265/277V 15 Included Not Included
RAK204E20 Sub-Base 265/277V 20 Included Not Included
RAK204E30 Sub-Base 265/277V 30 Included Not Included
RAK204 (AZ Series*—2800, 3800, 5200, 5500 and 5800 only)
Standard Sub-Base
The RAK204 sub-base is made of heavy-gauge steel to provide support
of the wall case. It has full base enclosure with break-away side channels, simple
connection to wall case, and 4-point leveling legs. The sub-base will adapt to
service conduit, circuit breakers and receptacles up to 30 amps. It may also be
used as a non-electrical sub-base to provide support for the unit.
Circuit
Kit No. Sub-Base Ampacity Chaseway Power Cord
RAK204D15P Sub-Base 230/208V 15 Included Included
RAK204D20P Sub-Base 230/208V 20 Included Included
RAK204D30P Sub-Base 230/208V 30 Included Included
RAK205CW
(AZ Series*—2200, 2500, 2800, 3200, 3500, 3800, 5200, 5500
and 5800 only)
Chaseway
Chaseway for wiring containment between junction box on
chassis and RAK204U sub-base.
RAK5157/5207/5307†
(AZ Series*—2800, 3800, 5500 & 5800 only)
265/277-Volt Universal Power Supply Kit
• 9-pin connector with three 7" 12-gauge conductor wires.
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800/3800/5800.
**RAK204U May be used with AZC and AZ 2100, 3100, 2600 and 5100.
†The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: All power cord kits and permanent
connection kits may be used on all units (of matching voltage). NOTE: 7,000 BTU models do not have 5,000 watt heaters.
11
13
Zoneline® units
RAK4157/4207/4307†
(AZ Series*—2800, 3800, 5500, 5800 and 7500 only)
230/208-Volt Universal Power Supply Kit
• 9-pin connector with three 7" 12-gauge conductor wires.
RAK4002 (AZ Series*—2200, 3200 and 5200 only)
Direct Connect Junction Box
(230/208 and 265/277 Volts)
RAK4002 junction box kit for permanent connection of 230/208and 265/277-volt units to building power supply.
Includes multi-circuit connector harness for use on value line
units. Junction box is included on 265/277-volt units.
RAK4002A (AZ Series*—2500, 2800, 3500 and 3800 only)
Direct Connect Junction Box
(230/208 and 265/277 Volts)
RAK4002 junction box kit for permanent connection of 230/208- and
265/277-volt units to building power supply.
Includes multi-circuit connector harness for use on value line units.
Junction box is included on 265/277-volt units.
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
†The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: All power cord kits and permanent connection
kits may be used on all units (of matching voltage). NOTE: 7,000 BTU models do not have 5,000 watt heaters.
12
Zoneline units
RAK4002B (AZ Series*—5500 and 5800 only)
Direct Connect Junction Box
(230/208 and 265/277 Volts)
RAK4002 junction box kit for permanent connection of 230/208and 265/277-volt units to building power supply.
Includes multi-circuit connector harness for use on value line
units. Junction box is included on 265/277-volt units.
RAK4002CW (AZ Series*)
Direct Connect Junction Box Wiring
(230/208 and 265/277 Volts)
In-line 3-pin connector and wiring harness.
Allows easy disconnect of direct connected applications.
RAK5172/5202/5302†
(AZ Series*—2800, 3800, 5500 and 5800 only)
15, 20, and 30 Amp (265/277 Volts)
Universal Power Supply
Required for 5200 series 265/277-volt units.
• Branch circuit plug to be used only in connection to
appropriate sub-base.
Circuit
Kit No. Volts Heater Wattage Ampacity
RAK5172 265/277 2,550 15
RAK5202 265/277 3,450 20
RAK5302 265/277 5,000 30
RAK8022
(AZ Series*—2200, 2500, 3200, 3500, 5200
and 5500 only)
Locking Door Kit
The RAK8022 provides door lock kit and key to prevent access to
Zoneline unit controls. Also provides two thumb screws for
securing the room cabinet to the chassis on the lower right and
left sides.
RAK8023 (AZ Series*—2800, 3800 and 5800 only)
Locking Door Kit
The RAK8023 provides door lock kit and key to prevent access to
Zoneline unit controls. Also provides two thumb screws for
securing the room cabinet to the chassis on the lower right and
left sides.
*
A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
†The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: All power cord kits and permanent connection
kits may be used on all units (of matching voltage). NOTE: 7,000 BTU models do not have 5,000 watt heaters.
13
15
Zoneline® units
RAK806 Universal Cover Label (10 covers per kit)
The RAK806 provides a cover for the control area to refer
room occupant to use a remote thermostat. Double-sided
tape provided.
RAA62 (AZ Series*—2200, 3200 and 5200 only)
Replacement Filters for AZ Models
(20 pairs per box)
The up-front filters on the GE Zoneline unit are conveniently
accessed by simply pulling them up from the top of the room
cabinet. By simplifying the task, filter cleaning is more likely to
occur on schedule and the unit will operate as efficiently as
possible. Sold in pairs.
RAA62A (AZ Series*—2500, 3500 and 5500 only)
Replacement Filters
• Replacement filters, in pairs.
• 20 pairs per box.
RAA63 (AZ Series*—2800, 3800 and 5800 only)
Replacement Filters
• Replacement filters, in pairs.
• 10 pairs per box.
RAK901L (AZ Series*)
Wall Case Insulation Kit
Five pieces of 13" x 14" x 1/4" adhesive-backed polyethylene
to insulate the inside of the RAB70 or RAB77A4 wall case. The
RAK901L minimizes the formation of moisture on exterior of
wall case.
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
14
Built-in units
15
17
Built-in units
RAD4A1 Drain Kit
Internal/External Drain Kit
Drain kit for use on “J” series wall cases. For more positive
control of condensate water, the RAD4A1 drain kit routes
condensate to the exterior or to the interior of the building
through the wall case. Suitable provision (field applied) should
be made to connect the drain tube to a drain system in the
building. Drain tube assembly is 1/2" O.D. copper.
Note: The RAG14E exterior grille is NOT compatible with the
RAD4A1 EXTERNAL drain tube. Use of this grille would require
the use of the INTERNAL TUBE configuration to drain the unit.
RAK65A1 Window Installation Kit
for “J” Series Built-in Units
Adapts built-in wall case for window installation. (This kit is
included in “J” series units designed for window installation.)
Window opening width—26-7/8" to 40". Window opening height
—16-3/8" minimum.
RAB46 Standard Wall Case
for “J” Chassis Built-in Unit
Solid-sided wall case fabricated of galvanized steel with baked
enamel (beige) finish. Welded areas are coated with a sealing
compound to help resist rust and corrosion. Polymer gasket
surrounds opening to assure tight weather seal. Aluminum grille
(RAG13) is included. Panels on interior and between case and
grille provide weather protection prior to installation of chassis.
RAB47/48 Tenant Option Wall Cases for “J” Chassis
When the air conditioner is offered as a tenant option, these
wall cases provide protection against outside elements.
Kit consists of an insulated steel front cover and a black-painted
ESP rear cover. When installed in a RAB46 standard wall case,
the kit will protect room from the outside elements prior to
installation of a GE “J” series chassis.
16
Built-in units
RAG13 Stamped Aluminum Exterior Grille “J” Series
Used to replace exterior grille on old “J” wall case to maximize
efficiency and capacity of new chassis. The grille is included
with new wall cases RAB46, 47, or 48.
RAG14E Architectural Louvered Exterior Grille
for “J” Series
Extruded aluminum grille for application with RAB46, 47, or 48.
NOTE: The RAG14E exterior grille is NOT compatible with the
RAD4A1 EXTERNAL drain tube. Use of this grille would require
the use of the INTERNAL TUBE configuration to drain the unit.
RAF622 Replacement Room Front
for Rounded Front “J” Chassis
Used as replacement grille for rounded front “J” chassis units.
(Not for use with high mount units.)
RAF622A Replacement Room Front
for Rounded Front “J” Chassis
• Replacement Room Front for “J” series chassis with Oval
Control Knob opening.
• Not for use on High Mount Models.
RAK690 Architectural Louver Grille Adapter
for “J” Chassis Units
Permits most existing architectural louvered grilles to be used
with sloped front or rounded front “J” chassis units. Kit consists
of two wire mesh screen sections, clips to attach screen to
existing wall case, and two aluminum air deflectors to be
mounted to new chassis.
17
19
Built-in units
RAK1072 Hotpoint Chassis Sleeve Adapter
Kit adapts Hotpoint ACXB 10 and ACXB 11 wall case (used with
ACTB chassis) to the sloped front or rounded front “J” chassis.
Existing case dimensions are 25-3/4" W, 16-7/8" H, 18-5/8" D.
All needed gaskets and hardware, including the outdoor grille,
are included.
RAK1082 Whirlpool Sleeve Adapter
Kit adapts Whirlpool Type 23W wall case for installation of the
sloped front or rounded front “J” model chassis. The Whirlpool
case dimensions are 25-7/8" W, 16-1/2" H, 23-1/8" D.
RAK1102/RAB30 (F Model Sleeve) Adapter
Kit adapts RAB30 wall case for installation of the sloped front or
rounded front “J” model chassis. The RAB30 case dimensions
are 26" W, 18" H, 24" D.
RAK123A64 Fedders Sleeve Adapter
Kit adapts Fedders “A” wall case for installation of the “J” wall
case (includes outdoor grille) and “J” model chassis. Existing
Fedders wall case dimensions are 27" W, 16-3/4" H, 16-3/4" D.
Kit consists of four gaskets which are applied to the wall case
to assure a tight weather seal between the two cases.
18
Built-in units
RAA72 Replacement Filter
for Rounded Front “J” Chassis
• Replacement filter for use in Room Fronts with
2 Round Control Knob openings ONLY.
• Washable/reusable nylon mesh filter.
• Order individually or by box of 20.
• Used for Standard or High Mount models.
RAA72A Replacement Filter
for Rounded Front “J” Chassis
• Replacement filter for use in Room Fronts with Oval Control
Knob openings ONLY.
• Washable/reusable nylon mesh filter.
• Order individually or by box of 20.
• Used for Standard or High Mount models.
19
21
Thermostats—Heat pump
RAK147 (A-B, AZ, and AZR Series*)
Wall-Mounted Remote Thermostat
RAK147 is used with heat pump units. Units have integral
low-voltage terminal board to connect with thermostat.
Temperature, operation mode, and fan operation are controlled
at wall-mounted thermostat.
Note: 3200/5200 series requires RAKOIM.
RAK348T1—Wall-Mounted Thermostat (transmitter)
(AZ3500, 3800, 5500, 5800 and 7500 series)
Heat Pump Wireless Programmable Remote Thermostat
RAK348R1—Chassis-Mounted Receiver
(AZ3500, 3800, 5500, 5800 and 7500 series)
Heat Pump Wireless Programmable Remote Receiver
• Programmable wireless remote thermostat with Single-Stage Cooling
and 2-Stage Heating for heat pump models.
• Programmable for 7-day programs.
• Battery-operated transmitter uses standard AA batteries.
• Receiver is mounted on chassis and wired to low voltage-terminals.
RAK148D1 (A-B, AZ, 3500, 3800, 5500, 5800,
7500 and AZR Series*)
Heat Pump Digital Remote Thermostat
• 24V AC digital remote wall thermostat with Single-Stage
Cooling and 2-Stage Heating for heat pump models.
• Requires 6-wire hook-up.
RAK148P1 (A-B, AZ, 3500, 3800, 5500, 5800,
7500 and AZR Series*)
Heat Pump Programmable Remote Thermostat
• 24V AC programmable remote wall thermostat with
Single-Stage Cooling and 2-Stage Heating for heat pump models.
• Programmable for 7-day or 5 + 2-day programs.
• Requires 6-wire hook-up.
* A-B Series: Zonelines® built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
20
Thermostats—Electric Resistance Heat
RAK163A1 (A-B, AZ, and AZR Series*)
Cooling with Electric Heat Remote Thermostat
RAK163A1 is used with resistance heat models. Units have
integral low-voltage terminal board to connect with thermostat.
Temperature, operation mode, and fan operation are controlled
at wall-mounted thermostat.
Note: 2200 series requires RAKOIM.
RAK364T1—Wall-Mounted Thermostat (transmitter)
(AZ2500, 2800, and 7500 series*)
Electric Heat Wireless Programmable Remote Thermostat
RAK364R1—Chassis-Mounted Receiver
(AZ2500, 2800, and 7500 series*)
Electric Heat Wireless Programmable Remote Receiver
• Programmable wireless remote thermostat with Single-Stage Cooling
and Single-Stage Heating for electric (resistance) heat models.
• Programmable for 7-day programs.
• Battery-operated transmitter uses standard AA batteries.
• Receiver is mounted on chassis and wired to low-voltage terminals.
RAK164D1 (A-B, AZ, 2500, 2800, 7500 and AZR Series*)
Cooling with Electric Heat Digital Remote Thermostat
• 24V AC digital remote wall thermostat with Single-Stage
Cooling and Single-Stage Heating for resistance heat models.
• Requires 5-wire hook-up.
RAK164P1 (A-B, AZ, 2500, 2800, 7500 and AZR Series*)
Cooling with Electric Heat Programmable Remote Thermostat
• 24V AC programmable remote wall thermostat with Single-Stage
Cooling and Single-Stage Heating for resistance heat models.
• Programmable for 7-day or 5+2-day programs.
• Requires 5-wire hook-up.
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500, Zoneline 2800, 3800, 5800.
21
23
Order information
Vertical Zoneline® units
NumberDescriptionModel Type*Page No.
RAK3152208/230V Universal power supply kit (15 Amp)AZ5
RAK3202208/230V Universal power supply kit (20 Amp)AZ5
RAK3302208/230V Universal power supply kit (30 Amp)
RAK4157208/230V Universal power supply kit (15 Amp)AZ5
RAK4207208/230V Universal power supply kit (20Amp)AZ5
RAK4307208/230V Universal power supply kit (30 Amp)AZ5
RAK5157265/277V Universal power supply kit (15 Amp)AZ5
RAK5207265/277V Universal power supply kit (20 Amp) AZ5
RAK5307265/277V Universal power supply kit (30 Amp)AZ5
RAVAL1Aluminum outdoor grilleAZ4
RAVRG1Access panel with return air grille for closet wallAZ4
RAVRG2Return air grille for common closet wallAZ5
RAVRMSWall-mounted room air sensorAZ3
RAVWP6Wall plenum for up to 6" wallsAZ3
RAVWP8Wall plenum for up to 8" wallsAZ3
RAVWP12Wall plenum for up to 12" wallsAZ3
RAVWP15Wall plenum for up to 15" wallsAZ4
Zoneline units
NumberDescriptionModel Type*Page No.
RAA62Replacement filters for AZ models (20 pairs per box) for 2200, 3200 & 5200 onlyAZ14
RAA62AReplacement filters (20 pairs per box) for 2500, 3500 & 5500 onlyAZ 14
RAA63Replacement filters (10 pairs per box) for 2800, 3800 & 5800 only
RAB71AStandard wall caseAll Zoneline7
RAB77A4SMC wall caseAll Zoneline7
RAD10Internal/external drain kitAll Zoneline7
RAF452Replacement standard room cabinet (2-position louvers) for 2200, 3200 & 5200 onlyAZ7
RAF452AReplacement standard room cabinet (2-position louvers) for 2200, 3200 & 5200 onlyAZ7
RAF453Replacement standard room cabinet (2-position louvers) for 2800, 3800 & 5800 onlyAZ8
RAG60Stamped aluminum exterior rear grilleAZ8
RAG61Architectural rear grille, beigeAZ8
RAG62Architectural rear grille, mapleAZ8
RAG63
RAG67Aluminum architectural outdoor grilleAZ8
RAKOIMOptional interface module for central desk control or remote thermostat control for 2200, 3200 & 5200 onlyAZ8
RAK40Air deflector kitAZ9
RAK4002Direct connect junction box, 230/208 and 265/277V for 2200, 3200 & 5200 onlyAZ12
RAK4002A230/208V direct connect junction box for 2500, 3500, 2800, 3800 onlyAZ12
RAK4002B230/208V direct connect junction box for 5500, 5800 onlyAZ13
RAK4002CW230/208V and 265/277 direct connect junction box wiringAZ13
RAK201Access plate coverAZC, AZ10
RAK204UStandard sub-base non-electricalAZ11
RAK205CWChaseway for RAK204U sub-baseAZ11
RAK3152208/230V Universal power supply kit (15 amp)AZ12
RAK3153Universal power supply, 15 Amp for 5200, 2800, 3800, 5500, 5800 only
RAK3202208/230V Universal power supply kit (20 amp)AZ12
RAK3203Universal power supply, 20 Amp for 5200 2800, 3800, 5500, 5800 only
RAK3302208/230V Universal power supply kit (30 amp)AZ12
RAK3303Universal power supply, 30 Amp for 5200 2800, 3800, 5500, 5800 only
RAK4157208/230V Universal power supply, 15 Amp for 2800, 3800, 5500, 5800, 7500 onlyAZ12
RAK4207208/230V Universal power supply, 20 Amp for 2800, 3800, 5500, 5800, 7500 onlyAZ12
RAK4307208/230V Universal power supply, 30 Amp for 2800, 3800, 5500, 5800, 7500 onlyAZ12
RAK5157265/275V Universal power supply, 15 Amp for 2800, 3800, 5500, 5800, 7500 onlyAZ11
RAK5207265/275V Universal power supply, 20 Amp for 2800, 3800, 5500, 5800, 7500 onlyAZ11
RAK5307265/275V Universal power supply, 30 Amp for 2800, 3800, 5500, 5800, 7500 onlyAZ11
RAK5172Universal power supply, 15 Amp, 265V for 5200 2800, 3800, 5500, 5800 onlyAZ13
RAK5202Universal power supply, 20 Amp, 265V for 5200 2800, 3800, 5500, 5800 onlyAZ13
RAK5302Universal power supply, 30 Amp, 265V for 5200 2800, 3800, 5500, 5800 only
Architectural rear grille, dark brownAZ8
AZ5
AZ14
AZ12
AZ12
AZ12
AZ13
All sales kits are stocked in Appliance Distribution Centers
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
22
Order information
Zoneline units
NumberDescriptionModel Type*Page No.
RAK204D15PStandard sub-base for 2800, 3800, 5200, 5500 & 5800 onlyAZ11
RAK204D20PStandard sub-base for 2800, 3800, 5200, 5500 & 5800 onlyAZ11
RAK204D30PStandard sub-base for 2800, 3800, 5200, 5500 & 5800 onlyAZ11
RAK204E15Standard sub-base for 2200, 2500, 3200 & 5800 onlyAZ11
RAK204E20Standard sub-base for 2200, 2500, 3200 & 5800 onlyAZ11
RAK204E30Standard sub-base for 2200, 2500, 3200 & 5800 only
RAK601Duct extension, register and trim flange AZC, AZ9
RAK602Duct extension, register and trim flange AZC, AZ 9
RAK605Duct adapter for 2100 & 3100 onlyAZ9
RAK6052Duct adapter for 2200, 3200, 2500, 3500, 2800 & 3800AZ9
RAK7012Duct adapter for replacement of A-B with rounded front AZ chassis for 2200, 3200, 2500, 3500, 2800 & 3800 onlyAZ10
RAK702Duct transition for replacement of AZC with sloped front AZ chassis for 2100 & 3100 onlyAZ10
RAK7022Duct transition for replacement of AZC with rounded front AZ chassis for 2200, 3200 2500, 3500, 2800 & 3800 onlyAZ10
RAK8022Locking door kit for 2200, 3200 & 5200 onlyAZ13
RAK8023Locking door kit for 2800, 3800 & 5800 only
RAK806Universal cover label (10 covers per kit)AZ14
RAK901LWall case insulation kitAZ14
Built-in units
NumberDescriptionPage No.
RAA72Replacement filter for rounded front "J" chassis – 2 round control knob openings19
RAA72AReplacement filter for rounded front "J" chassis – oval control openings19
RAB46Standard wall case for "J" chassis built-in unit16
RAB47Tenant option wall case for "J" chassis16
RAB48Tenant option wall case for "J" chassis16
RAK66Wall case insulation kit16
RAD4A1Drain kit16
RAF622Replacement room front for rounded front "J" chassis – 2 round control knob openings17
RAF622AReplacement room front for rounded front "J" chassis – oval control openings17
RAG13Stamped aluminum exterior grille for "J" series17
RAG14EArchitectural louvered exterior grille for "J" series17
RAK123A64Fedders sleeve adapter18
RAK65A1Window installation kit for "J" series16
RAK690Architectural louvered grille adapter for "J" chassis unit17
RAK1072Hotpoint® chassis sleeve adapter18
RAK1082Whirlpool® sleeve adapter18
RAK1102RAB30 (F model sleeve) adapter18
AZ11
AZ13
Thermostats
NumberDescriptionModel Type*Page No.
RAK147Wall-mounted mechanical remote heat pump thermostatA-B, AZ, AZR20
RAK148D1Heat pump digital remote thermostatA-B, AZ, AZR20
RAK148P1Heat pump programmable remote thermostatA-B, AZ, AZR20
RAK163A1
RAK164D1Cooling with electric heat digital remote thermostatA-B, AZ, AZR21
RAK164P1Cooling with electric heat programmable remote thermostatA-B, AZ, AZR21
RAK348T1Heat pump wireless programmable remote thermostatAZ20
RAK348R1
RAK364T1Cooling with electric wireless programmable remote thermostatAZ21
RAK364R1Cooling with electric wireless programmable remote thermostat receiverAZ21
All sales kits are stocked in Appliance Distribution Centers
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline® 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
Whirlpool® is a registered trademark of Whirlpool U.S.A.
Cooling with electric heat mechanical remote thermostatA-B, AZ, AZR21