Instructions for 120VAC/15A MAX Single Pole Switches with Pressure-Lock® (Push-In) & Screw Terminals.
Pressure-Lak® terminals for use on 15 Amp branch circuitswith No. W AWG solid copper conductors only. Do not use on 20A branch circuit. Screw terminals for use
power to the circuit at fuse box or circuit breaker. Remove wall plate and test to be sure power has been completely disconnected. 21 Remove old switch from wall box and disconnect
31 For screw terminals, strip off 3/4 ■ of insulation from the ends of the wires. Reconnectwiresto FIOT terminals on new switch, forming wireclocl«/ise 3/4 around screw os shown.
For push-in terminals, strip off 1/2" of insulation and insert into the push-in terminals. NOTE; To release Push-In wires, insert screwdriver into release slot and pull outwirewhile applying
(i
Form wires 3/4 around terminal screws (da nat overlap).
downward pressure to screwdriver.
4| Connect GREEN or BARE I'GROUNDING")
wire to GREEN screw on switch bracket.
5) Tighten oil screw terminals
securely to 14 in-lbs Install switch inwall box. Replace wall plate. Restore power.