Gasboy EDS-CCIS User Manual

Page 1
Gasboy CFN Series
EDS-CCIS
Credit and Debit Card Networks
Site Controller II
Versions 2.0 and above
part number: C35904
Gasboy International LLC
Page 2
Page 3
Gasboy CFN Series
Credit and Debit Card Networks
Site Controller II Versions 2.3 and above
03/12/03
C35904
Gasboy International LLC
Lansdale, Pennsylvania
Page 4
Gasboy International LLC
P. O. Box 309
Lansdale, PA 19446
Copyright 2003 by Gasboy International LLC
All rights reserved.
Printed in the United States of America.
The information in this document is confidential and proprietary. No furth er disclosure thereof shall be made without permission from Gasboy International LLC.
Gasboy International LLC believes that the information in this document is accurate and reliable. However, we assume no responsibility for i ts use, nor for any infringements of patents or other rights of third parties resulting from its use. We reserve the right to make changes at any time without notice.
REVISION RECORD OF THIS DOCUMENT
Part No. Date Published SC II Release Levels
C35904 May 1, 1997 Version 2.0 and above C35904 March 12, 2003 Version 2.3 and above
i
Page 5
Site Controller II Related Publications
Site Controller Il - version 2.0 and later
Part No. Title
C09212 SC II Manager’s Manual C01918 SC II Installation Manual C09213 SC II Configuration Manu a l C09326 SC II Configuration Manual, version 2.1 C09159 SC II Pocket Reference C09204 Check Point Reference Manual C09201 Profit Point Clerk’s Manual C09203 Profit Point Reference Manual C35745 Profit Point Clerk’s Manual - Modular series C35746 Profit Point Reference Manual - Modular series C09205 Enhancements Between Versions 1.0-2.0 C09215 Point of Sale and Shift Change
Credit and Debit Card Networks
C35931 Amoco/DataCard C35908 Gensar C35901 Buypass C35910 NaBANCO C35902 Alliance-Citgo C35911 NDC C35903 Comdata C35913 Sinclair C35904 EDS-CCIS C35914 SPS/Phillips C35905 FDR C35915 T-Chek C35906 BSI-FINA C35916 UFDA C35930 Gasboy Dial C35917 VDOT C35907 Gascard C35918 VisaNet C35909 Generic Dial C35919 BSI-ZION
Forms, Quick Refere nc e, Tutorials
C09134 SC II Configuration Orde r For m call SC II Sample Reports
Pump Interface
C09146 Pump Interface Manual (forthcoming) C01745 Current Loop Interface Unit Manual
Card Encoding and Miscellaneous
C09136 CFN Series Clubcard Format C01687 CFN Series Card Encoding Manual
Remote Communications
C09137 SC II-Host Communications C09138 SC II Raw Mode Communicatio ns C09140 Applications Guide for Host-SC Communications C09141 PC/SiteControl User’s Manual
Technical Publications
internal SC II Technical Manual C01759 CFN Diagnostic Manual
ii
Page 6
Page 7
Credit & Debit Card Ne tworks EDS/CCIS 1
EDS/CCIS
If you are connecting your site to the EDS/CCIS (Cummins Cash and Information Services, which is owned by EDS) network for card verification, use this manual for reference.

Cards accepted

The EDS network accepts only CCIS cards.

Preparing for configuration

Before you configure the Site Controller for connection to the network, you must determine the types of cards you will accept. Your EDS/CCIS representative will need to know this, too.
Before you configure, you must also make sure you know the following information. Consult with
your EDS/CCIS representative to determine the information you do not know.
• Your EDS/CCIS truck stop number.
• The primary and backup phone numbers you will use for authorizations.
• The baud rate for the modem communications.
• The phone number to call for authorization and settlement questions.
• The price code to use for refrigerated-trailer fuel, which is not subject to road taxes. You will need a modem for authorization. This is in addition to a modem used to poll transactions. Determine the Site Controller port to be used to connect to the EDS/CCIS host, and connect that port
to a Hayes modem capable of communicating at 1200 or 2400 baud or a modem that is 100% compatible with the Hayes standard. (See the Hayes dial-out settings in the Modem appendix in the Site Controller II Manager’s Ma nu a l.)
Use the command LOAD PHONE X to load the phone numbers supplied by EDS/CCIS into the Site
Controller. Substitute each of the nu m ber s (3 and 4) in the t able b e low to lo a d th e ph o ne n um b er s in dic a ted.
X Function of the Command LOAD PHONE X
3 Loads the primar y authorization phone number. 4 Loads the backup authorization phone number.

Configuring the Site Controller

Your Gasboy authorized service representative will configure your Site Controller. Before the service representative begins, make sure you have coll ected all the information that will be used for configuration.
Gasboy CFN Series
Page 8
2 EDS/CCIS Credit & Debit Card Networks

System Setup

System Parameters (SYS_PAR)

This information is provided for reference only. The menu programs initialize and/or stores the appropriate values for you in the system parameters.
Reader verification - page 4
Use remote verification (reader): Credit Use local verification (reader): Club Check mod 10 (reade r): None Check expiration date (reader): Credit (and optionally club)
Console verification - page 5
Use remote verification (reader): Credit Use local verification (reader): Club Check mod 10 (reade r): None Check expiration date (reader): Credit (and optionally club)
Serial port configuration - Page 8
Host handler channel: The number of the port used for communicating with the network. This is the same
port you connected to the modem. Host router data: Use for your EDS/CCIS truck stop number. More router data: Two-digit price level to use for refrigerated-trailer-fuel transactions. Host Handler Baud Rat e : The communications baud rate received from your EDS/CCIS representative. Send requests to host handler: Credit Host handler data: Two two-digit numbers; the default numbers are 00 and 20. Enter the numbers by typing:
00 20
ENTER ENTER ENTER
(Repeat as needed to exit host handler data.)
The first two digits are 00 if your modem is a Hayes 1200, 01 if your modem is a Hayes 2400, and
02 if it is a Hayes Optima.
The second two-digit number is a hexadecimal value for the number of seconds to allow for the
carrier to be received. The default 20 sets it for 32 seconds. Setting it for 10 would make it 16
seconds, 18 would be 24 sec onds, 28 would be 40 seconds, and 30 would be 48 seconds.
ENTER
Transaction miscellany - page 11
Verification timeout: 0 seconds (no timeout).
Gasboy CFN Series
Page 9
Credit & Debit Card Ne tworks EDS/CCIS 3

Console (CONSOLE)

The Allow Hand Entry of Card Data parameter in the Console configuration program must be set to Yes.

Island card reader (READER)

Put the Select Pump step before the Verify Card step if you use $ AMOUNT for the Enter Amount prompt, or if the fill limit of the pump is to be used to determine the authorization amount.

Special system setup

EDS/CCIS product names

Most card networks record the volume and dollar amounts of fuel purchased. EDS/CCIS also records the type of fuel purch as e d . The f irs t tw o c ha ra ct ers of th e prod uc t’s name are sent to EDS/CCIS as the pr od uc t code.
The product codes that EDS/CCIS recognizes are:
UR unleaded regular UP unleaded premium US unleaded super LR leaded regular LP leaded premium M1 diesel #1, mini-serve M2 diesel #2, mini-serve F1 diesel #1, full-serve F2 diesel #2, full-serve S1 diesel #1, self-serve S2 diesel #2, self-serve
Use the LOAD PRODUCT command to name the fuel products at your site. Name the products according to the chart above. The first two characters of each name must be the appropriate two char acters shown in the first column. The LOAD PRODUCT command has a 12-character limit for product names, so use the remaining 10 characters to further identi fy th e prod uc t. Fo r inst anc e, a recomme n de d n ame for sel f­serve diesel #2 would be S2_Diesel.

Special operation for EDS/CCIS

Unlike other networks, EDS/CCIS does not have a fo rmal settlement procedure onc e ever y 24 hours. Instead, when your site dials EDS/CCIS to requ e st a tran sactio n autho riza tio n, in fo rmati on on the prev iou s completed EDS/CCIS transaction is tran smitted at the same ti me. If there is a long tim e between EDS/CCIS transactions, data on the previous transaction wou ld no t reach EDS/CCIS in a timely man ne r.
In order to be sure that transaction completion s are set to EDS/CCIS on a tim ely basis, load a cron that will be executed 15 minutes before each hour. This will cause pending completions to be sent to EDS/ CCIS. For example,
LOAD CRON 1 @45 -settle
This command does nothing if there are no pending completions.

The transaction pointer

If you are not regularly polling a nd re sett ing the transac tio n p ointe r, then you should run the PURGE SIT E command once a day so you do not fill up the Site Controller’s memory.
Gasboy CFN Series
Page 10
4 EDS/CCIS Credit & Debit Card Networks

Customer prompts

The standard EDS/CCIS customer prom pt s are:
Unit Number (max 8 digits) Hub Number (max 6 digits) Trailer Number (max 8 digits) Reefer Y/N (yes or no)
Optional prompts sometimes shown by EDS/CCIS are:
Trip Number (max 12 digits) Driver Number (max 12 digits)
Note: The EDS/CCIS network allows alphabetic and numeric data in some fields, and supports additional entries not shown above. Gasboy does not currently allow alphabetic data, and does not support additional manual entries.