MDE-4641A
User Quick Reference Guide
for Atlas™ 8800
July 2010
Software Versions
For details on software versions, refer t o MDE-4331 Atlas™ Fuel Systems Installation
Manual, MDE-4363 Atlas Fuel Systems Owner’s Manual, and MDE-4334 Atlas
Startup and Service Manual.
Power on and Command Code 8 displays the current software version.
Display Pump Totals
•Press Enter after making selections.
•Press $Total.
• Select Grade.
•Press Volume Total.
• Select Grade.
•Press Enter to view Side 2 totals.
•Press Clear to exit.
Pin Code Entry
Level 1- Press F1, type 4-digit ID (default 2222), and press Enter.
Press F1 to exit any command code.
Press F2 to return to normal operation.
From Level 1
Command Code 1:
Program PPU
Press Enter after making selections.
• Enter 1
• Select Side**
• Select Grade
• Select Price Level
• Enter new PPU
(Repeat for other Side, Grade, and Price Level)
Command Code 2:
Program Two-Wire/Standalone
Press Enter after making selections.
• Enter 2
• Select Configuration
0 : Standalone
1 : Two-Wire*
2 : Pulse Output
Command Code 3:
Program Allocation
Press Enter after making selections.
• Enter 3
• Select Side**
• Select Hose/Grade
• Enter Allocation amount (000.0 default)
(Repeat for other Side, Hose, and Grade)
Command Code 4:
Program Manual Blank Display
Cash/Volume Pr eset Select
Press Enter after making selections.
• Enter 4
•Select Function Code 1
Function Code 1:
Manual Blank Displays
0 : Display OFF
1 : Display ON*
Command Code 5:
Test/Program
Customer Programmable Preset
Press Enter after making selections.
• Enter 5
•Select Configuration
0 : STOP Test/Program
1 : START Test/Program
(After the test is complete, refer to the
programming steps in MDE-2531
Pump/Dispenser Service Manual).
Command Code 6:
Memory Clear for Error Code 31
or 35
Press Enter after making selections.
• Enter 6
•Select 1
Command Code 7:
Program Totals Input
Press Enter after making selections.
• Enter 7
•Select Side
1 : Side A
2 : Side B
•Select Grade
•Press $Total
• Enter Money Total
(Repeat for other Side and Grade)
• Press Volume Total
(Repeat above procedure for Volume
Totals)
Command Code 8:
Display Version Number
Press Enter after making selections.
• Enter 8
•Select Software Optio n
1 : Pump Controller
* Default to system software if
pump/dispenser is not a Blender.
** 1 : Side A
2 : Side B
3 : Both Sides
Error Codes
31- Totals Data Error
35- Configuration Data Error
44- Pump Handle Up at Power Up
© 2010 GASBOY International. All Rights Reserved.
AtlasTM is a trademark of Gasboy International.
© 2010 GASBOY International · 7300 West Friendly Avenue · Post Office Box 22087
Call GASBOY Technical Support at: 1-800-444-5529
Greensboro, NC 27420 · Phone 1-800-444-5529
http://www.gasboy.com