GarrettCom 6K25e User Manual

Magnum 6K25e
Gigabit Fiber Switch
Hardware
Installation and User Guide
www GarrettCom com
..
Magnum Gigabit Fiber Switch Installation and User Guide (10/07)
Magnum
6K25e
Managed Fiber Switch
Hardware
Installation and User Guide
Part #: 84-00163Z (Rev. A)
Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is
a registered trademark of GarrettCom, Inc.
Important: The Magnum 6K25e Managed Fiber Switch contains no user serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. If problems are experienced with Magnum 6K25e Switch products, consult Section 6, Troubleshooting, of this User Guide.
Copyright 2007 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc.
Printed in the United States of America.
www GarrettCom com
..
i
Magnum Gigabit Fiber Switch Installation and User Guide (10/07)
Contacting GarrettCom, Inc
Please use the mailing address, phone and fax numbers and email address listed below:
GarrettCom, Inc.
47823 Westinghouse Dr.
Fremont, CA 94539-7437
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
email support@garrettcom.com
Federal Communications Commission
Radio Frequency Interference Statement
This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.
Canadian Emission This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil respecte toutes les exigences du Réglement sur le matériel du Canada. Cet appareil est Classe A..
www GarrettCom com
..
ii
Magnum Gigabit Fiber Switch Installation and User Guide (10/07)
TABLE OF CONTENTS Page
1.0
SPECIFICATIONS................................................................................1
1.1 Technical Specifications.......................................................................1
1.2 Ordering Information ...........................................................................4
2.0 INTRODUCTION..................................................................................7
2.1 Inspecting the Package and Product.....................................................7
2.2 Product Description - Magnum 6K25e Managed Fiber Switch...........7
2.2.1 Magnum 6K25e and 6K25eR chassis...........................................9
2.2.2 Eight-port SFF fiber modules 100Mb fiber........................................9
2.2.3
Eight-Port Copper Module, 6K8-RJ45
2.2.4
New PoE(Power Inside), model PI6KP8-45RJ (MDIX) 8-port
2.2.5 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX) 8-port
2.2.6 Six-Port “4 + 2”Combo Modules,
2.2.7 Four-Port 10 Mb mm Fiber ST Modules.................................13
2.2.8 Gigabit (1000Mbps) port modules.............................................14
2.2.9 Packet Prioritization, 802.1p QOS .............................................15
2.2.10 Frame Buffering and Flow Control............................................15
2.2.11 Managed Network Software (MNS-6K) for 6K25e-Series........16
3.0 INSTALLATION................................................................................21
3.1 Locating Magnum 6K25e Switches...................................................21
3.2 Connecting Ethernet Media................................................................22
3.2.1 Connecting Fiber Optic ST-type, “twist-lock”..........................22
3.2.2 Connecting Fiber Optic SC-type, "Snap-In" ..............................23
3.2.3 Connecting Single-Mode Fiber Optic ........................................23
3.2.4
Connecting Twisted Pair (RJ-45,CAT3, CAT5,)
3.2.5
Connecting Twisted Pair (CAT5E or better, )
3.2.6 Gigabit SFP (SF-factor Pluggable) Optical Transceivers...........25
3.3 Table-Top or Shelf Mounting.............................................................26
3.3.1 Rack-mounting (for 19” RETMA racks), regular 6K25es..........27
3.3.2 Rack-mounting, Reverse version of the Magnum 6K25es................28
3.4 Powering the Magnum Managed Fiber Switch..................................28
3.4.1 Alarm Contacts for monitoring internal power, Software Traps....29
3.5 6K25e Port Module (6KPM) Installation...........................................30
3.5.1 Preparation for Installing and Removing 6KPMs............................30
3.5.2 Installing 6KPM Cards in the Magnum 6K25e..........................32
3.6 Connecting the Console Terminal to Magnum 6K25e.......................36
3.6.1 RS-232 (DB-9) Console Com port (Serial port) pin...................37
4.1 Switching Functionality .....................................................................37
4.2 Status LEDs........................................................................................38
4.3 Up-link MDI-MDIX on RJ-45 port modules, for port 1 only............38
4.4 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports...............39
4.5 Flow-control, IEEE 802.3x standard..................................................40
4.6 Power Budget Calculations for Magnum 6K25e PM’s with Fiber Media
www GarrettCom com
..
iii
.............................................10
ST or SC
...............................12
...............................23
...................................24
............11
........12
.....41
Magnum Gigabit Fiber Switch Installation and User Guide (10/07)
5.0 6K25E MANAGED FIBER SWITCH PORT MODULES....................42
5.1 Inspecting the Package and Product...................................................43
5.2 6KPM Module Description................................................................43
5.2.1 6KP6-RJMST, multi-mode FX-ST “twist lock” Module...........44
5.2.1a 6KP6-RJ10ST FX-ST “twist lock” Combo Module ..................44
5.2.1b 6KP4-F10ST, “twist lock” Module..........................................44
5.2.1c 6KP4-FLSTFX, multi-mode FX-ST “twist lock” Module.......45
5.2.2. 6KP6-RJMSC multi-mode FX-SC “snap-in” Fiber connector
5.2.3
6KP6-RJSSC single-mode FX-SC-type, “snap-in” connector
5.2.4
6KP6-RJSSCL single-modeFX-SC-type, “snap-in” connector
5.2.4a 6KP6-RJ10ST multi-modeFL-ST-type, “twist-lock” connector
5.2.5 6KP8-MTRJSmall-Form-factor......................................................48
5.2.5a 6KP6-MT10ST FX , MTRJ Small-Form-Factor ST-Fiber port....48
5.2.6
6KP8-45MTmulti-mode FX MTRJ Small-Form-Factor............49
5.2.7 6KP8-MLC multi-mode LC connector Small-Form Factor.......49
5.2.8 6KP8-45LC, Combo multi-mode -LC small-formfactor............50
5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port...........................50
5.2.10 New PoE(Power Inside), model PI6KP8-45RJ (MDIX)
5.2.11 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX)
5.2.12 6KP8-45-2MT, multi-mode FX , MTRJ Small-Form-Factor.....53
5.2.12a
6KP8-45-2LCsingle-mode FX , LC Small-Form-Factor........53
5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), mm SC Connector..........54
5.2.13a
GBIC-LXSC & ZXSC Gigabit fiber (1000Mb), sm SC.........54
5.2.14 6KM-BLNK ...............................................................................55
6.0 TROUBLESHOOTING.......................................................................55
6.1 Before Calling for Assistance.............................................................55
6.2 When Calling for Assistance..............................................................56
6.3 Return Material Authorization (RMA) Procedure..............................56
6.4 Shipping and Packaging Information.................................................57
APPENDIX A: WARRANTY INFORMATION .........................................57
APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS.................58
APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION......60
Revisions Rev A 10/07 : This rev. is the initial release of the 6K25e manual.
...................46
.............46
............47
..........47
.....................51
.............52
www GarrettCom com
..
iv
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
The Magnum Line
INDUSTRIAL NETWORKING PRODUCTS
"DESIGNED AND MANUFACTURED IN THE USA"
OVERVIEW
GarrettCom, Inc. offers the premium-quality Magnum line of INDUSTRIAL conectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Industrial Grade, Carrier Class, POWER UTILITY and OEM applications where reliability is a primary consideration.
6K-Series Managed Field Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and match. Features SFF fiber and DC power in 1U units.
DX-Series Serial Device Routers, Ethernet and Serial 4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-negotiating
full switching performance. Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media types, full switching performance. mP62 and P62F “Outdoor” Ethernet SwitchES, for temperature uncontrolled locations, 6 10/100 and 2 100Mb fiber ports, can be connected in strings
Mixed-Media Fiber Hub, 16-port, 10/100 auto-sensing Dual Speed 8-port and 16-port, 10/100 auto-sensing HUBS Personal Switches, 10/100Mb
8 port dual-speed, Auto-negotiable with fiber option
Personal Hubs, 100Mb or 10/100Mb 8-port, with 2 switched ports (1 fiber built in) Personal Hubs, 10Mb series 8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-
port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series, All media combinations, incl. fiber ST, SC, mm.,
single mode
The “X-line” of configurable MiXed Media products: Stackable Concentrators, SNMP optional, 13-Ports Mini-Concentrators, 7 Ports, Repeaters, 2-Ports Repeater Port Modules (RPMs), 6 types for Ethernet media COAX Transceivers, 10Mb series Oct., 07
www GarrettCom com
..
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
1.0 SPECIFICATIONS
1.1 Technical Specifications
Performance
Filtering / Forwarding Rate: Ethernet:14,880 pps Fast Ethernet: 148,800 pps Gigabit Ethernet: 1, 488,000 pps
Switching Processing Type: Store and Forward with IEEE 802.3x full-
duplex flow -control, non-blocking
Data Rate: 10Mbps,100Mbps and 1000Mbps
Address Table Capacity: 4K node, self-learning with address aging Packet buffer size : 240KB for 10/100 and 120KB for 1000Mb Latency: 5 s + packet time (100 to 100Mbps) 15 s + packet time (10 to 10 Mbps, and 10 to 100Mbps)
Network Standards and Compliance, hardware
Ethernet V1.0/V2.0 IEEE 802.3: 10BASE-T, IEEE 802.3u: 100Base-TX, 100BASE-FX IEEE 802.3z: 1000BASE-X Ethernet(Auto-negotiation) IEEE 802.3ab: 1000BASE-X Ethernet IEEE 802.1p: Priority protocol IEEE 802.1d: Spanning tree protocol IEEE 802.1w: Rapid Spanning tree protocol IEEE 802.1q: VLAN Tagging
IEEE 802.3x: Flow Control Maximum 10 Mbps Ethernet Segment Lengths
Unshielded twisted pair - 100 m (328 ft) Shielded twisted pair - 150 m (492 ft) 10BASE-FL multi-mode fiber optic - 2 km (6,562 ft) 10BASE-FL single-mode fiber optic - 10 km (32,810 ft)
Maximum Standard Fast Ethernet Segment Lengths: 10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft) Shielded twisted pair - 150 m (492 ft) 100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft) 100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft) 100BASE-FX, half-duplex, single-mode - 412 m (1350 ft) 100BASE-FX, full-duplex, single-mode - 20.0 km (66K25e ft) 100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)
Maximum Standard Gigabit Ethernet Segment Lengths: 1000BASE-T (CAT5E or higher is recommended) - 100 m (328 ft) 1000BASE-SX, full-duplex, multi-mode(62.5m cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50m cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5m cable) -5Km
www GarrettCom com
..
1
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
Fiber Multi-mode connector types supported:
Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX Fiber Port, ST-type (twist-lock): Fiber optic m.-mode, 100BASE-FX
Fiber Port, 1000BASE-FX, GBIC modules
Fiber Single-mode connector types:
Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX Fiber Port, 1000BASE-FX, GBIC modules
LEDs: Per Port LK: Steady ON when media link is operational
ACT: ON with receiver port activity FDX/HDX: ON = Full-Duplex Mode OFF = Half-Duplex Mode 100/10: ON = 100Mbps speed OFF = 10 Mbps
Operating Environment
UL 60950 “Component Parts” temp. rating: 130 F (55C) IEC 60068 “Type Test” rating: -40to 185F (-40to 85C) Storage: -40to 185F (-40to 85C) Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude: -200 to 13,000 ft. (-60 to 4000m) Conformal Coating option: Request quote
Packaging
Enclosure: Rugged High strength metal. Suitable for stand-alone or rack-mounting Dimensions: 1.70in. H x 17.0in. W x 9.0in. D
4.32cm H x 43.2cm W x 22.9cm D Cooling method: Fan cooled, @ 3@ 7 cfm ea.
Management Console connector
DB-9 for RS-232 “ null-modem “ cable (sometimes called an Xmodem cable)
Power Supply (Internal)
AC Power Connector: IEC-type, male recessed at rear of chassis,
with adjacent manual ON-OFF switch (on AC models only) Input Voltage: 100 to 240 VAC (auto-ranging) Input Frequency: 47 to 63 Hz (auto-ranging) Power Consumption: 55 watts typical 60 watts max (for a fully loaded fiber model) 35 watts for a fully-loaded copper only model
DC Power Supply (Options)
-48VDC Power Input Voltage : -36 to -70 VDC 24VDC Power Input Voltage : 20 to 40 VDC 125VDC Power Input Voltage : 88 to 300VDC
Std. Terminal Block : “ -, GND, + ” Power Consumption: same as for AC models, see above
www GarrettCom com
..
2
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
For DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options (
are interrupted)
Per-port MDI or MDIX on RJ-45
The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45
ports., and eliminate the use of cross-over cable between the devices. Also port­specific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed using software commands.
, see Appendices B and C.
for continuity of operation when either of the DC input sources
Alarm Contact (Optional)
Alarm Contact option is offered as a configuration option. The two alarm contacts are SPST NC Form-C relays, and an open condition indicates abnormal status. The Hardware Alarm monitors internal power on the main board, and the Software Alarm is activated by one or more user-selected software traps.
Agency Approvals UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A
NEBS Level 3 and ETSI Certified for Carrier Central Offices IEEE 1613 Class 2 Environmental Standard for Electric Power Substations See also Note for Pow e r Substations in Section 3.2.4, 3.6.1, and 5.2.9 IEC 61850 EMC and Operating Conditions Class C for Power Substations
Warranty: Three years, return to factory Made in USA
NEBS Testing and Certification: NEBS certified Email
sales@GarrettCom.com
for details.
www GarrettCom com
..
3
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
1.2 Ordering Information
Magnum Managed Fiber Switch
MODEL DESCRIPTION
Magnum 6K25e Magnum 6K25e Managed Fiber Switch, base unit. May be configured with a selection of 10/100/1000 6K25e fiber and copper
port connector types, 25 total ports max. Wire speed filtering and forwarding across all ports, 802.3x flow control, 802.1p priority packet processing, self-learning 4K-node address table, large 240KB packet buffers for 10/100 and 120KB for 1000Mb. Plug-and­play switching services, front-mounted LEDs, internal auto-ranging AC power supply, 19" rack-mounting brackets. For licensed managed networks software, see MNS materials.
Magnum 6K25eR: “Reverse” model, same as Model 6K25e except the user ports and the power input connectors are in the rear. Two sets of LEDs (both rear and front) provide duplicate status data for viewing from either side.
Magnum 6K25e-48VDC: Same as 6K25e except the power input is –48VDC Magnum 6K25eR-48VDC: Same as 6K25eR except the power input is –48VDC Magnum 6K25e-24VDC: Same as 6K25e except the power input is 24VDC Magnum 6K25eR-24VDC: Same as 6K25eR except the power input is 24VDC Magnum 6K25e-125VDC: Same as 6K25e except the power input is 125VDC Magnum 6K25eR-125VDC: Same as 6K25eR except the power input is 125VDC
Configuration Options: Each Magnum 6K25e and 6K25eR base unit has four port module slots. The first
three (A,B,C) may be one of the modules below, one (slot D) may only be a Gigabit module. Select up to four port modules per base unit.
Magnum 6K25e Port Modules 6KP8-MTRJ SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors 6KP8-MLC SFF Fiber module, w/eight 100Mbps mm FX LC connectors 6KP8-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors 6KP8-RJ45 TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports 6KP4-F10ST “2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors 6KP4-FXST “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX ST connectors 6KP4-FLSTFX “2+2” ST Fiber module, w/ two 100Mb & two 10Mb ports, 2km 6KP8-45MT “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s
6KP8-45LC “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors 6KP8-45-2MT “6+2” module, w/six RJ-45 ports and two 2km mm MTRJ connectors 6KP8-45-2SLC “6+2” module, w/six RJ-45 ports and two 100Mb 15km sgl. mode FX
LC connectors
6KP6-RJMST “4+2” module, w/four RJ-45 ports and two 2km mm FX SC’s 6KP6-RJMSC “4+2” module, w/four RJ-45 ports and two 2km mm FX ST‘s 6KP6-RJSSC “4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s 6KP6-RJSSCL “4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s 6KP6-MT10ST “4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s 6KP6-RJ10ST “4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s
www GarrettCom com
..
4
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
For Gigabit module configuration options
GBPM-COTX One slot Gigabit 6K module for 6K25e Switches, uses one 6K25e slot
and provides one GBIC open transceiver port for a user-selectable GBIC transceiver module
GBIC-SXSC GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-SX port with mm SC fiber connector
GBIC-LXSC10 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE­LX/LH port with 1310nm sgl. mode SC(10km) fiber connector
GBIC-LXSC25 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE­LX/LH port with 1310nm sgl. mode SC(25km) fiber connector
GBIC-LXSC40 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX port with 1550nm, sgl. mode SC(40km) fiber connector
GBIC transceiver module for use in GBPM-COTX, one LX port with mm SC fiber connector
GBIC-LXSC70 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX port with 1550nm, sgl. mode SC(70km) fiber connector
GBIC-TP GBIC transceiver module for use in GBPM-xOTX, one 802.3ab 1000BASE-T port, RJ-45 connector
6KM-BLNK Blank cover for one 6K25e (A,B,or C) module slot opening in a Magnum 6K25e or 6K25eR chassis
CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ null­modem “ connection (sometimes called an Xmodem cable), used to connect a PC or a character terminal to the Management port.
CONSOLE USB Console attachment cable, serial to USB, cable with one DB9 for the managed Switch and a USB interface for the USB connector to a PC.
6K PoE Modules with 48VDC Pass-Through
Configuration options: only one A, B or C module slot of 6K-Series switch with 48VDC power input may be configured with a PoE Modules
New P6KP8-RJ45 8 port PoE module for 6ks with 48vdc PS, w/eight PoE power source 10/100 auto-negotiating auto cross RJ-45 ports.
New P6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 10/100 auto-negotiating auto cross RJ-45 ports
New P6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 2km mm FX MTRJ connectors
New P6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 2km mm FX LC connectors
New P6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 15km sm FX LC connectors
New P6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors
www GarrettCom com
..
5
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
New P6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 15km Sm FX LC connectors
New P6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 2km mm FX ST connectors
New P6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 2km mm FX SC connectors
New P6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 20km sm FX SC connectors
New P6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 40km sm FX SC connectors
New P6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 10 Mb 2km sm FL ST connectors
6K PoE Modules with 48VDC Power Inside
NOTE: For configuring in 6K Switches having AC /125VDC power i nput Configuration options: only one A, B or C module slot of 6K-Series switch with
48VDC power input may be configured with a PoE Modules
New 6KAC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full- width rack-mount 6K switch with AC power input.
New 6K125VDC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full-width rack-mount 6K switch with 125VDC power input.
New PI6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 10/100 auto-negotiating auto cross RJ-45 ports
New PI6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 2km mm FX MTRJ connectors
New PI6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 2km mm FX LC connectors
New PI6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 15km sm FX LC connectors
New PI6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors
New PI6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 15km Sm FX LC connectors
New PI6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 2km mm FX ST connectors
New PI6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 2km mm FX SC connectors
New PI6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 20km sm FX SC connectors
New PI6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 40km sm FX SC connectors
New PI6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four POE power source and two 10 Mb 2km sm FL ST connectors
GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice.
www GarrettCom com
..
6
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
2.0 Introduction
2.1 Inspecting the Package and Product
Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
This package should contain:
1 Magnum 6K25e Managed Fiber Switch, base unit (configured with user-selected port module options)
1 AC Power Cord (U.S. and other 115 VAC only) 1 Set of metal “Ears” for 19” rack mounting
1 Installation and User Guide (this manual) 1 Product Registration Card Remove the items from the shipping container. Be sure to keep the shipping
container should you need to re-ship the unit at a later date. To validate the product warranty, please complete and return the enclosed Product Registration Card to GarrettCom, Inc. as soon as possible.
In the event there are items missing or damaged, contact the party from whom you purchased the product. If the unit needs to be returned, please use the original shipping container if possible. Refer to Section 6, Troubleshooting, for specific return procedures.
2.2 Product Description - Magnum 6K25e Managed Fiber Switch
The Magnum Managed Fiber Switch boosts the performance of large Ethernet LANs, typically serving as a “backbone” switch. It has the flexibility to handle a mix of both fiber and twisted-pair switched ports along with Gigabit backbone port options. Industry-standard IEEE 802.1p QOS prioritization is included, providing high performance switching services for both “smooth” streaming and “bursty” data traffic.
The Magnum 6K25e has up to 25 ports capacity, all of which may be configured as fiber ports, but still offers a space-saving rack-mount chassis that is only 1U (1.70in. or 4.32cm) high. The “mixed-media” capability allows user selection of all popular flavors of fiber port connectors and modes, including even 10Mb fiber along with Gigabit ports. It also allows a mix of 10/100Mb RJ-45 (copper) ports and a fiber
www GarrettCom com
..
7
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) Gigabit port in the same unit. This flexibility is achieved via a family of 6K25e port
modules for copper and fiber-built-in (emphasizing Small Form Factor fiber for high fiber port density), 6-port modules for fiber and RJ-45 combinations, and 1Gb port module selections using GBICs. These modules can be factory configured in a base chassis unit (or may be changed in the field by trained technicians) to adapt the unit to the user’s application and Ethernet cabling requirements. Even evolving mixed-media requirements for 10Mb and 100Mb fiber and copper as well as Gigabit ports can be handled by the Magnum 6K25e product.
The 6K25e managed switches also provides PoE option via Power-pass-through and power –inside PoE modules and allows the users to select a wide option of combo PoE modules to support 802.3af pd devices. See details in sec 5.2.10 and 5.2.11. The Power Sourcing Equipment (PSE), and are fully compatible with Powered Devices (PD)(e.g wireless access points, IP phones) that comply with the IEEE 802.3af PoE standard. The PoE switch ports have an auto-sensing algorithm, so that they provide power only to
802.3af, PoE end devices. PoE is managed by a multi-stage handshake to protect equipment from damage and to manage power budgets .The PoE ports will discontinue supplying power when the PoE powered devices are disconnected, and support the 802.3af PoE PSE standard for over-current protection, under-current detection, and fault protection.
The packaging and power-input options target the Magnum 6K25e at heavy­duty applications. The chassis mounting rack style may be “regular” (with the ports and LEDs in the front and the power input and management console connector in the rear) or “Reverse” (with the ports and LEDs and the power-input and the management console connector all in the rear and a duplicate set of LEDs in the front). Rack widths accommodated include standard 19” RETMA, ETSI, and 23” Telco. Input power may be AC, or –48VDC for Telco environments, or 24VDC for Industrial applications.
Designed for use in network traffic centers, the Magnum 6K25e Managed Fiber Switches are easy to install and use. Addresses of attached nodes are automatically learned, maintained and aged out, adapting the switching services to network changes. LEDs provide status information on each port. The Magnum 6K25e provides high performance plug-and-play hardware operation, 802.1p packet prioritization in hardware, and industry-standard managed networks software functionality, all in convenient 1U rack-mount packages.
www GarrettCom com
..
8
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
2.2.1 Magnum 6K25e and 6K25eR chassis
The Magnum 6K25e is a 19” rack-mountable Ethernet Switch with three eight-port slots (A, B, and C) and one Gb-only slot (D) for configuration flexibility. Slots A, B and C may be configured with any of a large selection of fiber and copper port types and combinations of types, typically eight ports per module, but sometimes 6 or 4 ports or even one Gb port. Slot D may be configured with a Gb module that accepts GBICs. The port types configurable using the 4 slots allows the 6K25e to efficiently serve a large variety of applications, especially using fiber media. The Magnum 6K25e port modules are normally factory installed, but may be changed or added in the field. (See Section 5)
Figure 2.2.1a: “Regular” 6K25e front view, configured for 24 +1 Gb ports
Status LEDs are part of each port module and are viewable when connecting the Ethernet media. A “regular” rack-mount 6K25e is shown in Figure 2.2.1a. On “Reverse” rack-mount models, there is a duplicate set of LEDs on the other (front) side for normal status viewing from that direction. Of course, with management, the port status data is also available in software.
2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiber
1 3 5 7
ACT F/H
ACT F/H
LK LK LK LK
ACT F/H
ACT F/H
LK LK LK LK
2 4 6 8
ACT F/H
ACT F/H
ACT F/H
ACT F/H
Fig.2.2.2 : SFF Fiber Port
Modules, 6K8-MTRJ (to the left)
and 6K8-MLC or -SLC
(below)
www GarrettCom com
..
9
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
In an eight-port SFF fiber port module, all of the fiber ports are of the same speed (100Mb), mode, and connector type. Models are available with Small Form Factor
(SFF) are multi-mode MT-RJ or LC-
1 3 5 7
AC F/H
AC
LK LK LK L
F/H
2 4 6 8
AC F/H
AC
LK LK LK L
F/H
2 4 6 8
type connectors, and single-mode
ACT F/H
ACT
LC-type connectors.
F/H
ACT F/H
ACT
port modules for the Magnum
F/H
The 100Mb fiber eight-
6K25e’s normally are set (factory default) to operate in full-duplex mode for best fiber distance and performance. Using the 6K25e’s MNS software, the user may select full- or half-duplex mode per-port through set-up of the software (See Magnum 6K25e MNS Software Manual) for the flexibility to adapt to any FDX or HDX type of Fast Ethernet devices).
There are three LED’s per fiber port. The Link (LK) LED indicates “ready for operation” on that port when lit, the F/H LED indicates operation in full-duplex mode when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving Activity on the port. A fiber cable must be c onne c ted into a SFF port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port.
2.2.3
Eight-Port Copper Module, 6K8-RJ45
The 6K25e-Series’s 8-port Copper port module, model 6K8-RJ45, provides eight 10/100Mb switched RJ-45 ports. The 10/100Mb switched
10/100
F/ H
10/100
1 3 5 7
2 4 6 8
LK
ACT
LK
ports normally (as a default setting) are independently N-
F/H
ACT
way auto-negotiating, and auto­crossover(MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode, i.e., each independently selects a mode and speed to match the device at the other end of the twisted pair cable.
(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will automatically determine the other side of connection to make the connection, and
www GarrettCom com
..
10
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) eliminate the need of cross-over cable.
On the model 6K8-RJ45 module, there are four LEDs for each port, two in the connector and two separate. The LK (Link) LED indicates “ready for operation” on that port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb speed when OFF (when auto­negotiation is not disabled).
10/100
1 3 5 7
The FDX/HDX LED is ON
F/ H
to indicate full-duplex operation and OFF to indicate half-duplex mode. A twisted
2 4 6 8
10/100
F/H
pair cable must be connected into an RJ-45 port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port.
Using the 6K8-Series (MNS-6K) management software, the user may disable auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See Magnum MNS-6K Software Manual for details info.).
2.2.4 New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port
The New PoE RJ-45 ports act similar to regular RJ-45 ports, except they have capability of providing power on each port to power up the PD devices, per the
6KP8-45RJ
8 Port@ 10/100Mb Copper ports
1 3 5
10/10
F/ H
2 4 6
10/10
F/H
1
3
LK/ACT
LINK
PoE
2
10/10
FULL/HALF
4
LK/AC
POE
LK/AC
POE
2
4
IEEE802.3af PoE standard. Only 4 x RJ­45 (10/100) ports maxm. support POE(Power Inside)
1
option in one rack mounted 6K-unit. The power inside PoE option is factory
3
configured and equipped with the necesasary power option to support four
802.3af PoE pd devices. The 4-RJ45 POE
module are also available with mix –n-match with fiber modules. Please check the
LK
ACT
LK
ACT
www GarrettCom com
..
11
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) ordering information Sec.1.2. for all the various PI6K PoE modules option.
The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when connected properly to a 803.af compliant PD device on that port. When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data traffic is not affected by PoE.
LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK/ACT, as shown in the diagram.
2.2.5 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8­port
The PoE (Power-pass-through) RJ-45 ports act similar to regular RJ-45 ports, except they have capability of providing power on each port to power up the PD devices,
6KP8 -45RJ
per the IEEE802.3af PoE standard. The Power Pass­through PoE modules are totally dependent upon the powerful -48VDC input
1
power supply to support more RJ-45 (10/100) ports. Each port requires atleast 15watts to power
3
up the PoE PD devices. Maxm. one PoE modules can be configured in the A, B or C slot of any 6K s with -48vdc power input.
1
3
1 3 5
10/10
F/ H
2 4 6
10/10
F/H
LK/ACT
LINK
PoE
2
10/10
FULL/HALF
4
LK/AC
POE
LK/AC
POE
2
4
The PoE modules are also available with mix –n-match with fiber modules. Please check the ordering information Sec.1.2 for all the various P6K PoE modules option.
The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when connected properly to a 803.af compliant PD device on that port. When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data traffic is not affected by PoE.
LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK/ACT, as shown in the diagram.
2.2.6 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb fiber
4@RJ-45 + 2@ 100Mb ST or SC
The combo six-port modules are combinations of copper and fiber media, available as four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-mode fiber ST, SC or single mode SC or Long Reach SC ports. For ports numbering, ports 1,3,5,7 are copper, ports 2 and 6 are fiber, ports 4 and 8 are not present.
The four RJ-45 ports operate just like the 8-port copper module with auto-cross
www GarrettCom com
..
12
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07) (MDIX) feature to eliminate the use of cross-over cable, and the two fiber ports operate
at 100Mbps full-duplex (default). User mode control per port through the MNS software is also the same.
On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port, which indicate status the same as described for the 6K8-RJ45 in Section 2.2.3 above. The fiber port’s LEDs indicate status the same way as described for the SFF fiber modules in Section 2.2.2 above. Color-coding on the panel of the module shows which LEDs belong to which port.
10/100
F/H
ACT F/H
1 3 5 7
ACT
2 6TX RX
LK
F/H
TX LK RX
LK
port modules are also available with 4@ MTRJ 100Mb mm SFF fiber and
ACT
2@10Mb fiber mm ST ports, and with 4@ RJ45 10/100 copper and 2@10Mb
The Magnum Combo six-
fiber mm ST ports. The
4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of the module is as described for those port types above. For detailed information about 10Mb mm ST fiber half of the module, see Section 2.2.5.
The Magnum Combo
10/100
1 3 5 7
six-port modules are also available
LK
with 4@ MTRJ 100Mb mm SFF
F/H
ACT F/H
2 6TX RX
LK
ACT F/H
TX LK RX
ACT
fiber and 2@10Mb fiber mm ST ports, and with 4@ RJ45 10/100 copper and 2@10Mb fiber mm ST
ports. The 4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of the module is as described for those port types above. For detailed information about 10Mb mm ST fiber half of the module, please check section 2.2.5.
2.2.7 Four-Port 10 Mb mm Fiber ST Modules
ACT F/H
TX RXLK
1 5
ACT F/H
2 6
LK
TX RX
The 4port @10Mb ST fiber modules behave the same as the 8@100Mb ST
www GarrettCom com
..
ACT F/H
ACT F/H
TX RXLK
T
LK R
13
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
K
K
fiber modules except for the 10Mb speed. For ports numbering, ports 1, 2, 5, 6 are present, ports 3, 4. 7, 8 are not present. The default setup on the 10Mb fiber module is half-duplex, which allows the Magnum 6K25e Switch to connect to any 10Mb hub or media converter or almost any other device with a 10Mb fiber Ethernet port. User mode control per port through the MNS software is the same as the other 6K25e modules. The fiber ports support fiber cabling distances according to the 10BASE-FL standard, i.e., 2km distance for multi-mode fiber. (Single-mode for up to 10Km distance may be available as a special order configuration).
2.2.8 Gigabit (1000Mbps) port modules
The Magnum 6K25e offered a wide option Gigabit speed with multiple choice for the modular slot. While up to two Gigabit modules (maxm.) can be configured in the modular slot. The Gigabit port option for the modular slot comes in couple of different
ACT F/
TX RXL
ACT F/
TX RXL
ACT F/
TX LK RX
The 6K25e Modules provide a GBIC opening for insertion of industry-standard GBICs to provide Gigabit (Gb) media flexibility. GBIC models are available for both multi-mode (550m) and single-mode (10, 25, 40, 70)km fiber options, and for Gigabit copper as well, with new models appearing often.
configuration. The Giga port has been offered as single Gigabit module comes in flavor of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber ports) as shown below .
1@ 1000Mb Fiber SC + 2@ 100Mb SC
The 1000Mb Gigabit fiber-port modules on the Magnum 6K25es are normally set (factory default) to operate at
ACT F/
TX RXL
1 3 5 7
10/100
AUTO mode for best fiber distance and performance. The 1000Mbps SC fiber-optic
F/
module on the Gigabit -SX and Gigabit-LX 1@ 1000Mb Fiber SC + 4@10/ 100Mb transceivers are compatible with the IEEE 802.3z Gigabit standards. There are two LEDs mounted on each Gigabit port module. The Gigabit fiber
port is by default configured at AUTO mode, and can be fix at 1000Mbps speed full­duplex mode at any times and has LEDs that indicate LK (Link status) and ACT (receiving activity) on that port when lit.
www GarrettCom com
..
14
L
ACT
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
2.2.9 Packet Prioritization, 802.1p QOS
Quality of Service means providing consistent predictable data delivery to
users from datagram paths that go all across a network. As a LAN device, the Magnum 6K25e can do its part to prevent any QOS degradation while it is handling Ethernet traffic through its ports and buffers.
The Magnum 6K25e switching hardware supports the IEEE 802.1p standard and fulfills its role in support of QOS, giving packet processing priority to priority tagged packets according to the 802.1p standard. In addition to hardware support for QOS, the MNS software (R2) supports two priority queues that can be shared across the eight levels of defined packet priorities for application-specific priority control by the user through software configuration settings.
2.2.10 Frame Buffering and Flow Control
Magnum 6K25e’s are store-and-forward switches. Each frame (or packet) is
loaded into the Switch’s memory and inspected before forwarding can occur. This technique ensures that all forwarded frames are of a valid length and have the correct CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all of the available bandwidth to be used for valid information.
While other switching technologies (such as "cut-through" or "express") impose minimal frame latency, they will also permit bad frames to propagate out to the Ethernet segments connected. The "cut-through" technique permits collision fragment frames (which are a result of late collisions) to be forwarded which add to the network traffic. Since there is no way to filter frames with a bad CRC (the entire frame must be present in order for CRC to be calculated), the result of indiscriminate cut­through forwarding is greater traffic congestion, especially at peak activity. Since collisions and bad packets are more likely when traffic is heavy, the result of store-and­forward operation is that more bandwidth is available for good packets when the traffic load is greatest.
When the Magnum 6K25e Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices sending packets to cause “flow control”. This tells the sending devices to temporarily stop sending traffic, which allows a traffic catch-up to occur without dropping packets. Then, normal packet buffering and processing resumes. This flow­control sequence occurs in a small fraction of a second and is transparent to an observer.
Another feature implemented in Magnum 6K25e Switches is a collision-based flow­control mechanism (when operating at half-duplex only). When the Switch detects that
www GarrettCom com
..
15
Loading...
+ 48 hidden pages