GarrettCom 6K16 User Manual

0 (0)
GarrettCom 6K16 User Manual

Magnum 6K16-Series

Managed Fiber Switch

Two 6K16s mounted side-by-side on Tray

Magnum 6K16V mounted vertically

Hardware

Installation and User Guide

www . GarrettCom . com

Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06)

Magnum6K16-Series

Managed Fiber Switch

Hardware

Installation and User Guide

Part #: 84-00136 (Rev. B)

Trademarks

Ethernet is a trademark of Xerox Corporation

NEBS is a trademark of Telcordia Technologies

UL is a registered trademark of Underwriters Laboratories

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.

Important: The Magnum 6K16-Series Managed Fiber Switch contains no user serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. If problems are experienced with Magnum 6K16-Series Switch products, consult Section 6, Troubleshootings, of this User Guide.

Copyright © 2006 GarrettCom, Inc. All rights reserved. No part

of this publication may be reproduced without prior written permission from

GarrettCom, Inc.

Printed in the United States of America.

www . GarrettCom . com

i

Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06)

Contacting GarrettCom, Inc

Please use the mailing address, phone and fax numbers and email address listed below:

GarrettCom, Inc.

47823 Westinghouse Dr.

Fremont, CA 94539-7437

Phone (510) 438-9071

Fax (510) 438-9072

Website: http://www.GarrettCom.com email support@garrettcom.com

Federal Communications Commission

Radio Frequency Interference Statement

Radio Frequency Interference Statement

This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.

Canadian Emission

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil respecte toutes les exigences du Réglement sur le matériel du Canada. Cet appareil est Classe A..

www . GarrettCom . com

ii

Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06)

Table of Contents..............................................................................

Page

1.0

SPECIFICATIONS ...............................................................................

1

1.1

Technical Specifications ......................................................................

1

1.2

Ordering Information...........................................................................

4

2.0

Introduction............................................................................................

8

2.1

Inspecting the Package and Product ....................................................

8

2.2

Product Description - Magnum 6K16-Series (6K16/6K16V) .............

9

2.2.1a

Magnum 6K16V, Managed Fiber Switch..................................

10

2.2.1b

Magnum 6K16, Managed Carrier Class Switch ........................

11

2.2.1c

Magnum 6K16-Series family (6K16 and 6K16V), At a glance. 13

2.2.2

Eight-port SFF fiber modules , 100Mb fiber .............................

13

2.2.3

Eight-Port Copper Module, 6K8-RJ45 ......................................

14

2.2.4

New PoE(Power Pass-through), model P6KP8-RJ45, 10/100Mb 8-port....

15

2.2.5

Six-Port “4 + 2” Combo Modules,100Mb fiber.........................

16

2.2.6

Four-Port 10 Mb and 100Mb mm Fiber ST Modules..............

17

2.2.7

Gigabit (1000Mbps) port modules.............................................

17

2.2.8

Packet Prioritization, 802.1p QOS.............................................

19

2.2.9

Frame Buffering and Flow Control............................................

20

2.2.10

Managed Network Software ( MNS-6K ) for Magnum 6K8-

 

Series

20

 

2.3

Features and Benefits.........................................................................

22

2.4

Applications.......................................................................................

23

3.0

Installation...........................................................................................

27

3.1

Locating Magnum 6K16-Series Switches..........................................

27

3.2

Connecting Ethernet Media ...............................................................

27

3.2.1

Connecting Fiber Optic ST-type, “twist-lock”..........................

28

3.2.2

Connecting Fiber Optic SC-type, "Snap-In"..............................

28

3.2.3

Connecting Single-Mode Fiber Optic........................................

29

3.2.4

Connecting Twisted Pair ...........................................................

29

3.2.5

Connecting Twisted Pair............................................................

30

3.2.6

Connecting Gigabit Media Using GBICs ..................................

30

3.3

DIN-Rail Mounting (Magnum 6K16V).............................................

30

3.3.1

Mounting Dimensions for 6K16Vwith metal brackets ..............

32

3.3.2

Rack-mounting optionS for Telco and ETSI Standard ..............

33

3.4

Powering the Magnum 6K16-Series Managed Fiber Switch.............

34

3.5

Alarm Contacts for monitoring internal power, and Software Traps....

34

3.6

6K16-Series Port Module (6KPM) Installation .................................

35

3.6.1

Preparation for Installing and Removing 6KPMs............................

35

3.6.2

Installing 6KPM Cards in the Magnum 6K16-Series ................

37

3.6.3

Removing 6KPM Cards.............................................................

40

3.7

Connecting a Management Console Terminal to Magnum 6K16-

 

Series 41

3.7.1RS-232 (DB-9) Console Com port (Serial port) pin assignments.41

www . GarrettCom . com

iii

Magnum 6K16-Series Managed Fiber Switch Installation & User Guide

(04/06)

4.0

OPERATION .......................................................................................

42

4.1

Switching Functionality.....................................................................

42

4.2

Status LEDs .......................................................................................

43

4.3

Up-link Manual Switches set as (=) , for RJ-45 port only .................

43

4.4

Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports...............

43

4.5

Flow-control, IEEE 802.3x standard .................................................

45

4.6Power Budget Calculations for Magnum 6K16 PM’s with Fiber Media 45

5.0Intro - Magnum 6K16/6K16V Managed Fiber Switch Port Modules47

5.1

Inspecting the Package and Product ..................................................

47

5.2

6KPM Module Description................................................................

47

5.2.1

6KP6-RJMST, Combo Module..................................................

48

5.2.1a

6KP6-RJ10ST, Combo Module .................................................

48

5.2.1b

6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module49

5.2.1c

6KP4-FLSTFX, Module ...........................................................

49

5.2.2. 6KP6-RJMSC Fiber connector .......................................................

50

5.2.3

6KP6-RJSSC connector............................................................

51

5.2.4

6KP6-RJSSCL connector..........................................................

51

5.2.4a

6KP6-RJ10ST connector ..........................................................

52

5.2.5 6KP8-MTRJ, Small-Form-factor....................................................

52

5.2.5a

6KP6-MT10ST, ST-Fiber port.....................................................

53

5.2.6

6KP8-45MT, FX , MTRJ Small-Form-Factor ..........................

53

5.2.7

6KP8-MLC, LC connector Small-Form Factor .........................

54

5.2.8

6KP8-45LC, Combo factor .......................................................

54

5.2.9

6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port ..........................

55

5.2.10

New PoE(Power Pass-through), P6KP8V-RJ45 (MDIX), 8-port........

56

5.2.11

6KP8-45-2MT, FX , MTRJ Small-Form-Factor........................

57

5.2.12a

6KP8-45-2LC, single-mode FX , LC Small-Form-Factor .....

57

5.2.13GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector57

5.2.13a GBIC-LXSC Gigabit fiber (1000Mb), SC Connector ...........

58

5.2.14 6KM-BLNK...............................................................................

59

6.0

TROUBLESHOOTING ......................................................................

59

6.1

Before Calling for Assistance ............................................................

60

6.2

When Calling for Assistance .............................................................

60

6.3

Return Material Authorization (RMA) Procedure .............................

61

6.4

Shipping and Packaging Information.................................................

61

APPENDIX A: WARRANTY INFORMATION.........................................

62

APPENDIX B : Internal DC Power Supply Options....................................

62

APPENDIX C: Internal DC Dual-Source Power Option.............................

65

www . GarrettCom . com

iv

Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06)

Revisions

06/07: Minor updates to power supply ratings 05/07: minor update to notes for power substations

04/06: minor updates as PoE modules option added on Sec 5.2.10/11 10/05: minor updates as MDIX support added on all RJ-45 port modules 02/05: minor updates and tweaks on LC port module

07/04 : 6K16 carrier class managed switch has been added with 6K16V 01/04 : Added Section 3.5 (Alarm Contacts) and 3.7.1 (Console Port pins) 12/03: Updated Section 3.3 “DIN-Rail”, and Appendix B “DC Power” 10/03 : Initial Release with Rev A

www . GarrettCom . com

v

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

THE MAGNUM LINE

Industrial networking products

"Designed and Manufactured in the USA"

Overview

GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUMLINE OF INDUSTRIAL CONECTIVITY PRODUCTS WITH INDUSTRYSTANDARD FUNCTIONALITY AND BUILT-IN FIBER CONFIGURABILITY. MAGNUM PRODUCTS ARE DESIGNED FOR USE IN DEMANDING INDUSTRIAL GRADE, CARRIER CLASS, POWER UTILITY AND OEM APPLICATIONS WHERE RELIABILITY IS A PRIMARY CONSIDERATION.

6K-SERIES MANAGED FIELD SWITCHES, GIGABIT, 100 AND 10 MBPS, FIBER AND COPPER PORTS, MIX-AND MATCH. FEATURES SFF FIBER AND DC POWER IN 1U UNITS.

DX-SERIES SERIAL DEVICE ROUTERS, ETHERNET AND SERIAL

4K-SERIES SWITCHES, 100 AND 10 MBPS, COPPER PORTS WITH OPTIONAL FIBER PORT, WITH AUTO-NEGOTIATING FULL SWITCHING PERFORMANCE.

QUAD-SERIES FIBER SWITCHES, 100 & 10MBPS, FIBER AND COPPER PORTS, MIXEDSPEED AND MIXED-MEDIA TYPES, FULL SWITCHING PERFORMANCE.

MP62 AND P62F “OUTDOOR” ETHERNET SWITCHES, FOR TEMPERATURE UNCONTROLLED LOCATIONS, 6 10/100 AND 2 100MB FIBER PORTS, CAN BE CONNECTED IN STRINGS

MIXED-MEDIA FIBER HUB, 16-PORT, 10/100 AUTO-SENSING

DUAL SPEED 8-PORT AND 16-PORT, 10/100 AUTO-SENSING HUBS

PERSONAL SWITCHES, 10/100MB

8 PORT DUAL-SPEED, AUTO-NEGOTIABLE WITH FIBER OPTION

PERSONAL HUBS, 100MB OR 10/100MB 8-PORT, WITH 2 SWITCHED PORTS (1 FIBER

BUILT IN)

PERSONAL HUBS, 10MB SERIES 8-PORT + AUI, STACKABLE TO 5 HIGH, + OPTIONAL BNC OF FIBER PORT 8 OR 9-PORT AND 4 OR 5-PORT PERSONAL HUBS, W/ MAN. UP-LINK

SW.

MEDIA CONVERTERS, 10MB AND 100MB SERIES, ALL MEDIA COMBINATIONS, INCL.

FIBER ST, SC, MM., SINGLE MODE

THE “X-LINE” OF CONFIGURABLE MIXED MEDIA PRODUCTS:

STACKABLE CONCENTRATORS, SNMP OPTIONAL, 13-PORTS

MINI-CONCENTRATORS, 7 PORTS, REPEATERS, 2-PORTS

REPEATER PORT MODULES (RPMS), 6 TYPES FOR ETHERNET MEDIA

COAX TRANSCEIVERS, 10MB SERIES

APR, 07

www . GarrettCom . com

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

1.0SPECIFICATIONS

1.1Technical Specifications

Performance

Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps

Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet(1000Mb): 1, 488,000 pps

Switching Processing Type: Store and Forward with IEEE 802.3x fullduplex flow -control, non-blocking

Data Rate: 10Mbps,100Mbps and 1000Mbps

Address Table Capacity: 4K node, self-learning with address aging Packet buffer size : 240KB for 10/100 and 120KB for 1000Mb

Latency: 5 µs + packet time (100 to 100Mbps)

15 µs + packet time (10 to 10 Mbps, and 10 to 100Mbps)

Network Standards and Compliance, hardware

Ethernet V1.0/V2.0 IEEE 802.3: 10BASE-T,

IEEE 802.3u: 100Base-TX, 100BASE-FX

IEEE 802.3z: 1000BASE-TX Ethernet (Auto-Negotiation)

IEEE 802.3ab: 1000BASE-TX Ethernet

IEEE 802.1p: Priority protocol

IEEE 802.1d: Spanning tree protocol

IEEE 802.1q: VLAN Tagging

IEEE 802.3x: Flow Control

Maximum 10 Mbps Ethernet Segment Lengths

 

 

Unshielded twisted pair

-

100 m (328 ft)

Shielded twisted pair

-

150 m (492 ft)

10BASE-FL multi-mode fiber optic

-

2 km (6,562 ft)

10BASE-FL single-mode fiber optic

-

10 km (32,810 ft)

Maximum Standard Fast Ethernet Segment Lengths:

10BASE-T (CAT 3, 4, 5 UTP)

- 100 m (328 ft)

100BASE-TX (CAT 5 UTP)

- 100 m (328 ft)

Shielded twisted pair

-

150 m (492 ft)

100BASE-FX, half-duplex, multi-mode

- 412 m (1350 ft)

100BASE-FX, full-duplex, multi-mode

 

- 2.0 km (6,562 ft)

100BASE-FX, half-duplex, single-mode

 

- 412 m (1350 ft)

100BASE-FX, full-duplex, single-mode

- 20.0 km (66K16-Series ft)

100BASE-FX, full-duplex, Long Reach

- 40.0 km (122K ft)

Maximum Standard Gigabit Ethernet Segment Lengths:

1000BASE-T (CAT5e or higher is recommended) - 100 m (328 ft) 1000BASE-SX, full-duplex, multi-mode(62.5µm cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km

Fiber Multi-mode connector types supported:

Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX Fiber Port, ST-type (twist-lock): Fiber optic m.-mode, 100BASE-FX

Fiber Port, 1000BASE-FX, GBIC modules

www . GarrettCom . com

1

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

Fiber Single-mode connector types:

Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX Fiber Port, 1000BASE-FX, GBIC modules

LEDs: Per Port (one set at the port, one set on rear top) 6K16V only Per Port (one set at the port) 6K16

LK: Steady ON when media link is operational ACT: ON with receiver port activity FDX/HDX: ON = Full-Duplex Mode

OFF = Half-Duplex Mode 100/10: ON = 100Mbps speed

OFF = 10 Mbps

Operating Environment

Ambient Temperature:

-40° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating -60° to 205° F (-50° to 95°C) for IEC 60068 Type Test short term rating

Storage Temperature: -60°to 210°F (-50°to 100°C) Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude: -200 to 13,000 ft. (-60 to 4000m)

Conformal Coating (humidity protection) option: Request quote

Alarm Relay Contacts

One NC indicating internal power, one NC software controllable

Packaging

Enclosure: Rugged High strength sheet metal. Dimensions: 9.5 in. H x 8.75 in. W x 1.75 in. D

24.1 cm H x 22.2 cm W x 4.4 cm D

Cooling method: Convection, designed for vertical mounting, no fans (6K16V) Cooling method: fan cooling, three rear fans (6K16)

Weight: 4.21 lbs. (1.9 kg)

Management Console connector

DB-9 for RS-232 “null-modem” cable (sometimes called an X-modem cable)

Power Supply (Internal)

AC Power Connector: IEC-type, male recessed at rear of chassis, Input Voltage: 100 to 240 VAC (auto-ranging)

Input Frequency: 47 to 63 Hz (auto-ranging) Power Consumption:

50 watts typical (for a fully loaded fiber model)

30 watts typical (for a fully-loaded copper only model)

DC Power Supply (Options)

-48VDC Power Input Voltage : -36 to -70 VDC 24VDC Power Input Voltage : 18 to 36VDC 125VDC Power Input Voltage : 88 to 300VDC Std. Terminal Block : “ -, GND, + ”

Power Consumption: same as for AC models, see above

www . GarrettCom . com

2

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

For DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options (for continuity of operation when either of the DC input sources are interrupted), see Appendices B and C.

Per-port MDI or MDIX on RJ-45

The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45 ports., and eliminate the use of cross-over cable between the devices. Also port-specific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed using software commands.

Mountings:

Vertical mounting only Suitable for wall or DIN-Rail mounting (6K16V) Horizontal , Rack-mount, 2 units side-by-side on 19” or 21”rack (6K16)

Agency Approvals and Standard Compliance

Magnum 6K16V

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A NEBS Level 3 and ETSI Compliant

IEEE 1613 Environmental Standard for Electric Power Substations

See also Note for Power Substations in Section 3.2.4, 3.7, and 5.2.9 IEC 61850 EMC and Operating Conditions Class C for Power Substations NEMA TS-2 and TEES for traffic control equipment

Magnum 6K16

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class B IEEE 1613 Class 2 Environmental Standard for Electric Power Substations

See also Note for Power Substations in Section 3.2.4, 3.7, and 5.2.9 IEC 61850 EMC and Operating Conditions Class C for Power Substations NEBS Level 3 and ETSI Compliant

NEMA TS-2 and TEES for traffic control equipment

Warranty: Three years, per UL 60950 temperature rating

Made in USA

Email sales@GarrettCom.com for details.

www . GarrettCom . com

3

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

1.2Ordering Information

Magnum Managed Fiber Switch (16 ports max)

MODEL DESCRIPTION

Magnum 6K16V -Magnum 6K16V Managed Fiber Switch, base unit for vertical mounting. Worldwide AC power. May be configured with a selection of 10/100/1000 fiber and copper port connector types, 16 total ports max. Two metal brackets for vertical wall or panel mounting. Wire speed filtering and forwarding across all ports, 802.3x flow control, 802.1p priority packet processing, self-learning 4K-node address table, large 240KB packet buffers for 10/100 and 120KB for 1000Mb. For licensed managed networks software (MNS-6K and S-ring), See separate data sheets.

Magnum 6K16V -24VDC: Same as 6K16V except the power input is 24VDC

Magnum 6K16V -5VDC: Same as 6K16V except the power input is 5VDC reg & fused

Magnum 6K16V-48VDC: Same as 6K16V except the power input is –48VDC Magnum 6K16V-125VDC: Same as 6K16V except the power input is 125VDC

Configuration Options:

Each Magnum 6K16V base unit has TWO port module slots

Magnum 6K16V Port Modules

6KP8V-MTRJ

SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors

6KP8V-MLC

SFF Fiber module, w/eight 100Mbps mm FX LC connectors

6KP8V-SLC

SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors

6KP4V-FXSC

“2+2” 100Mb Fiber module, w/ four 100Mb 2km FX SC connectors

6KP4V-FXST

“2+2” 100Mb Fiber module, w/ four 100Mb 2km FX ST connectors

6KP4V-F10ST

“2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors

6KP4V-FLSTFX

“2+2” ST Fiber module, w/ two 100Mb & two 10Mb ports, 2km

6KP8V-45-2MT

“6+2” module, w/six RJ-45 ports and two 100Mb 2km FX MTRJ’s

6KP8V-45-2LC

“6+2” module, w/six RJ-45 ports and two 100Mb 2km FX LC’

6KP8V-RJ45

TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports

6KP8V-45MT

“4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s

6KP8V-45MLC

“4+4” module, w/four RJ-45 ports and four 2km mm LC connectors

6KP8V-45SLC

“4+4” module, w/four RJ-45 ports and four 2km sgl-m LC connectors

6KP6V-RJMST

“4+2” module, w/four RJ-45 ports and two 2km mm FX ST’s

6KP6V-RJMSC

“4+2” module, w/four RJ-45 ports and two 2km mm FX SC‘s

6KP6V-RJSSC

“4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s

6KP6V-RJSSCL

“4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s

6KP6V-MT10ST

“4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s

6KP6V-RJ10ST

“4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s

6KM-BLNK

Blank cover for one 6K16V (A,B) module slot opening in a 6K16V

Gigabit (1000Mb) module option for Magnum 6K16V

6KP5V-G4RJ

“G+2” module, w/one GBIC transceiver&four 10/100 RJ-45 connectors

6KP3V-G2SC

“G+2” module, w/one GBIC transceiver and two 100Mb 2km FX SC

fiber ports connector

www . GarrettCom . com

4

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

GBPMV-2OTX Two-port Gigabit 6K module for 6K16-Series Switches, provides two GBIC open transceiver port for a user-selectable GBIC transceiver module

GBPMV-COTX One slot Gigabit 6K module for 6K16-Series Switches, uses one 6K16Series slot and provides one GBIC open transceiver port for a user-selectable GBIC transceiver module

DIN-RAIL-VRM Set of two DIN-Rail holders for a secure vertical mount of a 6K16Series unit, with screws to attach to metal mounting brackets and to the 6K16-Series case.

Magnum 6K16 -Magnum 6K16 Managed Carrier Class Switch, base unit for Horizontal or rack-mounting. Worldwide AC power. May be configured with a selection of 10/100/1000 fiber and copper port connector types, 16 total ports max. Wire speed filtering and forwarding across all ports, 802.3x flow control, 802.1p priority packet processing, self-learning 4K-node address table, large 240KB packet buffers for 10/100 and 120KB for 1000Mb. For licensed managed networks software (MNS-6K and S-ring), See separate data sheets.

Magnum 6K16 -24VDC: Same as 6K16 except the power input is 24VDC Magnum 6K16-48VDC: Same as 6K16 except the power input is –48VDC Magnum 6K16-125VDC: Same as 6K16 except the power input is 125VDC

Configuration Options:

Each Magnum 6K16 base unit has TWO port module slots

Magnum 6K16 Port Modules

6KP8-MTRJ

SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors

6KP8-MLC

SFF Fiber module, w/eight 100Mbps mm FX LC connectors

6KP8-SLC

SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors

6KP4-FXSC

“2+2” 100Mb Fiber module, w/ four 100Mb 2km FX SC connectors

6KP4-FXST

“2+2” 100Mb Fiber module, w/ four 100Mb 2km FX ST connectors

6KP4-F10ST

“2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors

6KP4-FLSTFX

“2+2” ST Fiber module, w/ two 100Mb & two 10Mb ports, 2km

6KP8-45-2MT

“6+2” module, w/six RJ-45 ports and two 100Mb 2km FX MTRJ’s

6KP8-45-2LC

“6+2” module, w/six RJ-45 ports and two 100Mb 2km FX LC’s

6KP8-RJ45

TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports

6KP8-45MT

“4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s

6KP8-45MLC

“4+4” module, w/four RJ-45 ports and four 2km mm LC connectors

6KP8-45SLC

“4+4” module, w/four RJ-45 ports and four 2km sgl-m LC connectors

6KP6-RJMST

“4+2” module, w/four RJ-45 ports and two 2km mm FX ST’s

6KP6-RJMSC

“4+2” module, w/four RJ-45 ports and two 2km mm FX SC‘s

6KP6-RJSSC

“4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s

6KP6-RJSSCL

“4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s

6KP6-MT10ST

“4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s

6KP6-RJ10ST

“4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s

6KM-BLNK

Blank cover for one 6K16-Series (A,B) module slot opening in a 6K16-

Series

 

www . GarrettCom . com

5

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

Gigabit (1000Mb) module option for Magnum 6K16V

6KP5-G4RJ “G+2” module, w/one GBIC transceiver and four 10/100 RJ-45 connectors

6KP3-G2SC “G+2” module, w/one GBIC transceiver and two 100Mb 2km FX SC fiber ports connector

GBPM-2OTX Two-port Gigabit 6K module for 6K16-Series Switches, provides two GBIC open transceiver port for a user-selectable GBIC transceiver module

GBPM-COTX One slot Gigabit 6K module for 6K16-Series Switches, uses one 6K16Series slot and provides one GBIC open transceiver port for a user-selectable GBIC transceiver module

K16-RMB Set of two rack-mount brackets for one 6K16 unit in a 19” RETMA 1U rack space, with screws to attach the metal mounting brackets to the case. Can add Model K16- EXTN-KIT to extend to ETSI and 23” rack width.

K16-2TRAY Rack mount tray fro holding two side-by-side 6K16’s in a 19” 1.5U rack space, each 6K16 unit individually removable for service. Can add Model K16-EXTN- KIT to extend to ETSI and 23” rack width.

K16-EXTN-KIT Kit of extender brackets for converting one K16-RMB or one K162TRAY to ETSI and/or to 23” Telco rack.

Gigabit(1000Mb) Transceivers option for Mangum 6K16-Series (6K16V/6K16)

GBIC-SXSC GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-SX port with mm SC fiber connector

GBIC-LXSC10 GBIC transceiver module for use in GBPM-xOTX, one 1000BASELX/LH port with 1310nm sgl. mode SC(10km) fiber connector

GBIC-LXSC25 GBIC transceiver module for use in GBPM-xOTX, one 1000BASELX/LH port with 1310nm sgl. mode SC(25km) fiber connector

GBIC-ZXSC40 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX port with 1550nm, sgl. mode SC(40km) fiber connector

GBIC transceiver module for use in GBPM-COTX, one LX port with mm SC fiber connector

GBIC-ZXSC70 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX port with 1550nm, sgl. mode SC(70km) fiber connector

GBIC-TP GBIC transceiver module for use in GBPM-xOTX, one 802.3ab 1000BASE-T port, RJ-45 connector

CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ nullmodem “ connection (sometimes called an X-modem cable), used to connect a PC or a character terminal to the Management port.

CONSOLE USB Industry standard serial cable, DB-9 connectors for RS-232 “ nullmodem “ connection (sometimes called an X-modem cable) to connect to a managed switch, and a USB port to connect to a PC

Please see next page for PoE option and Modules

www . GarrettCom . com

6

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

6K PoE Modules with 48VDC Pass-Through

Configuration options: only one A, B or C module slot of 6K-Series switch with 48VDC power input may be configured with a PoE Modules

New P6KP8-RJ45 8 port PoE module for 6ks with 48vdc PS, w/eight PoE power source 10/100 auto-negotiating auto cross RJ-45 ports.

New P6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 10/100 auto-negotiating auto cross RJ-45 ports

New P6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 2km mm FX MTRJ connectors

New P6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 2km mm FX LC connectors

New P6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 15km sm FX LC connectors

New P6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors

New P6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and four 100 Mb 15km Sm FX LC connectors

New P6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 2km mm FX ST connectors

New P6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 2km mm FX SC connectors

New P6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 20km sm FX SC connectors

New P6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 40km sm FX SC connectors

New P6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 10 Mb 2km sm FL ST connectors

GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice.

www . GarrettCom . com

7

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

2.0Introduction

2.1Inspecting the Package and Product

Examine the shipping container for obvious damage prior to installing this

product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.

This package should contain:

1Magnum 6K16-Series Managed Fiber Switch, base unit (configured with user-selected port module options installed)

1 AC Power Cord (U.S. and other 115 VAC only) if AC version

1 Set of two metal vertical mounting brackets, with screws to the case 1 Installation and User Guide (this manual)

1 Product Registration Card

Remove the items from the shipping container. Be sure to keep the shipping container should you need to re-ship the unit at a later date. To validate the product warranty, please complete and return the enclosed Product Registration Card to GarrettCom, Inc. as soon as possible.

In the event there are items missing or damaged, contact the party from whom you purchased the product. If the unit needs to be returned, please use the original shipping container if possible. Refer to Section 6, Troubleshooting, for specific return procedures.

www . GarrettCom . com

8

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

2.2Product Description - Magnum 6K16-Series (6K16/6K16V)

Magnum 6K16-Series Managed Switches, available as Magnum 6K16 and

6K16V models, and equipped with 16 modular ports, is specially designed to focus on two different aspects of Ethernet markets to meet their needs and requirements. 6K16Series managed switches provide modularity of fiber and copper ports, a mix and combination of 10Mb, 100Mb and Gigabit speed ports, with comprehensive management software in a compact industrial-grade package. Setting a new standard for Industrial and Carrier Class applications, heavy duty Ethernet Switch jobs are readily accommodated with an extended temperature rating of -40˚C to 60˚C by the UL Component Parts method, or -50˚C to 95˚C by the IEC 60068 Type Test method. With options such as all popular DC power input types, worldwide AC power and DIN-Rail mounting, the hardened Magnum 6K16-Series is a “multi-purpose” Industrial Ethernet Switch.

The large family of port modules offer the choice of all fiber media (all connector types, multiand single-mode) and 10/100 Mb auto-negotiating RJ-45 ports. Standard GBIC ports can be configured for a variety of Gigabit cabling types and distances.

The 6K16Series managed switches also provides PoE option via power – inside PoE modules on one of A or B slot and allows the users to select a wide option of combo PoE modules to support 802.3af pd devices. See details for PoE modules in sec 5.2.10. The Power Sourcing Equipment (PSE), and are fully compatible with Powered Devices (PD)(e.g wireless access points, IP phones) that comply with the IEEE 802.3af PoE standard. The PoE switch ports have an auto-sensing algorithm, so that they provide power only to 802.3af, PoE end devices. PoE is managed by a multi-stage handshake to protect equipment from damage and to manage power budgets .The PoE ports will discontinue supplying power when the PoE powered devices are disconnected, and support the 802.3af PoE PSE standard for over-current protection, under-current detection, and fault protection.

High performance features include non-blocking speed on all ports and 802.1p QoS Traffic Prioritization. Magnum 6K16-Series switches are “plug-and-play” ready for use as backbone switches where a mix of bursty data traffic and priority streaming traffic for VoIP and audio/video “Triple Play” applications are present.

Magnum 6K16-Series Fiber Switches are provided with LAN management software including SNMP, Tagand Port-based VLANs, IGMP Snooping and Port

www . GarrettCom . com

9

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

Security with control via Web and command line interface (CLI). For high availability LANs using ring topologies, Spanning Tree Protocol, Link-Loss-Learn and S-Ring are available. See the Managed Networks Software (MNS-6K) and S-Ring datasheets for additional details on the comprehensive set of software programs and options.

Magnum 6K16-Series Managed Fiber Switches have heavy duty metal cases and auto-ranging power supplies for operation with standard AC power worldwide. Internal DC power supplies are optional. All DC power input types (5V, 24V, 48V, 125V) are supported, and dual source input is optional on all except 5VDC..

Alarm Relay contacts provided on each Magnum 6K16-Series Switch monitor the hardware and software providing a loss of power signal and userdefined software events through traps. See Section 3.5 for details.

The wide selections of port modules are key to the flexibility and adaptability.

2.2.1a Magnum 6K16V, Managed Fiber Switch

The Magnum 6K16V model of 6K16-Series family, is primarily designed to use for vertical mount applications. Equipped with the multi-media fiber/copper solutions,

multiple speed 10/100/1000Mb support, rich MNS-6K management features , hardware and software alarms and convection cooling (no fans), the Magnum 6K16V easily qualifies for use in transportation and traffic control systems, power utilities and industrial factory-floors. For the fast growing demands of video surveillance systems with segments requiring Gigabit backbone interconnections, the Magnum 6K16V managed switches are easy to install and operate.

The next generation of industrial applications will need advanced managed network software, operation at extended temperatures, fiber ports modularity, support for selfhealing ring structures, redundancy, security and gigabit backbone configurability. The Magnum 6K16V has all of these, in a very sleek and robust metal case with a wide

www . GarrettCom . com

10

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

choice of popular DC options or industry standard AC internal input.

The plug-n-play Magnum 6K16V managed fiber switch, should be mounted vertically using the vertical mounting brackets which come with the unit or by using the DIN- RAIL-KIT (optional) for Din rail mounting.

Loaded with versatile management software (MNS-6K), the 6K16V switch can be easily managed and monitored.

Dual LEDs on the front and the connector side help the vertically mounted 6K16V to be monitored easily. The modular designed Magnum 6K16V managed fiber switch can support of maximum four Gigabit modules (fiber or copper) to meet any demand of bandwidth required applications. In a on-going demand of diversified designed Ethernet application the Magnum 6K16V is a finest solution to meet and satisfy those requirement by the rich modular structure. The Relay contacts for external “ALARM” is another additional feature which allows the Magnum 6K16V to monitor the internal power failure and controlled via hardware or software trap control.

2.2.1b Magnum 6K16, Managed Carrier Class Switch

The rack-mountable 6K16 model of 6K16-Series family, is a modular managed Carrier class Switch, which can be mounted horizontally as rack-mount, shown in the picture below.

Specially designed to cater the requirements for carrier class Telco applications or factory floor and office purpose solutions, the Magnum 6K16 can be mount side-by-side on a 19” rack mount tray to provide the needs of port density. Equipped with three fan at the rear, the fan-cooled Magnum 6K16, through its modular designed and diversified support of 10/100 or 1000Mb speed can be a excellent gear for the carrier class and factory floor applications.

The Multi-media (copper and fiber) support loaded with rich management feature of MNS-6K easily qualified this carrier class switch to meet any demands and

www . GarrettCom . com

11

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

requirement of this space. Magnum 6K management features not only allow the easy monitoring of the switch through SNMP, but also protect the network through its security features of port-security, SNMP3, VLAN etc. The redundant feature through STP, RSTP and S-ring, LLL also allow to configure and control the switch as a fault tolerant device or self-healing in a ring topology applications

The NEBS and ETSI compliant Magnum 6K16, rack mountable, and specially designed to support the popular DC options of (24VDC, -48VDC. AND 125VDC) as well as AC input, easily qualify and make a popular and reliable contender for the carrier-class Telco and factory-floor applications.

The rich-choice of modules in various flavors of all fiber connectors, multi or single mode, combo of copper and fiber, and a diversification option to select 10Mb fiber or 100Mb copper or 1000Mb copper/Fiber are some of the primary benefits, which allow the Magnum 6K16 to fulfill all the demands and requirements of carrier-class, office and factory-floor applications.

The Relay contacts for external “ALARM” is another additional feature which allow the Magnum 6K16 to monitor the internal power failure and controlled via hardware or software traps.

www . GarrettCom . com

12

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

2.2.1c Magnum 6K16-Series family (6K16 and 6K16V), At a glance

Comparison chart

Features

6K16

6K16V

 

 

 

Mounting

Horizontal, Rack-mount Vertical, Din-Rail Panel

Cooling

fan cooled, 3 fans

Convection

 

 

 

Temp. Rating

Office & Factory

Factory & Outdoors

 

Regular

Only “V” suffice modules

Module Model #s

e.g 6KP8-RJ45

e.g 6KP8V-RJ45

LEDs

Front, with ports

Front and rear top

 

 

 

Special Ratings

NEBs and ETSI

P1613 for substations

Power input

24VDC/-48VDC/125VDC

Same

 

or AC(Regular)

 

MNS-6K Software

Managed, preloaded

Same

 

 

 

Redundancy

LLL, STP,RSTP, S-Ring

Same

 

Controlled via

 

Alarm Contact

Hardware & Software

Same

 

 

 

Media

Copper & Fiber

Same

Port Module

can be 10,100 or 1000Mb

Same

 

 

 

Suitable for Applications

Telco, Office, Industrial

 

Utility,Industrial,Outdoors

 

 

Operation

Plug-n-Play

Same

 

 

 

MDI/MDIX on RJ-45

Yes

Same

 

 

 

NoteThe Redundant S-Ring feature for self-healing ring sold separately.

2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiber

1

3

5

7

ACT

 

 

 

ACT

F/H

 

 

 

 

F/H

ACT

 

 

 

 

ACT

F/H

LK

LK

LK

LK

F/H

ACT

 

 

 

 

ACT

F/H

 

 

 

 

F/H

ACT

 

 

 

 

ACT

LK 2

4 LK

6LK

8LK

 

F/H

F/H

 

 

 

 

 

Fig.2.2.2 :

SFF Fiber Port Modules,

6K8-MTRJ (to the left) and

6K8-MLC or –SLC - (below)

www . GarrettCom . com

13

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

In an eight-port SFF fiber port module, all of the fiber ports are of the same speed (100Mb), mode, and connector type. Models are available with Small Form Factor (SFF) are multi-mode MT-RJ or LC-type connectors, and single-mode LC-type connectors.

The 100Mb fiber eight-port modules for the Magnum 6K16-Series’s normally are set (factory default) to operate in full-duplex mode for best fiber distance and

performance. Using the 6K-MNS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

software, the user may select fullor

 

 

1

3

 

 

5

 

 

7

 

 

 

 

half-duplex mode per-port through

 

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACT

 

F/H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F/H

 

 

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACT

set-up of the software (See Magnum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F/H

 

F/H

LK

 

4

LK

6

LK

8

L

 

 

 

 

2

 

 

 

 

 

 

 

 

6K-MNS Software Manual) for the

 

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACT

 

F/H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F/H

flexibility to adapt to any FDX or

 

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F/H

 

F/H

LK

2

4

LK

6 LK

8 L

 

HDX type of Fast Ethernet devices).

There are three LED’s per fiber port. The Link (LK) LED indicates “ready for operation” on that port when lit, the F/H LED indicates operation in full-duplex mode when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port.

2.2.3Eight-Port Copper Module, 6K8-RJ45

The 6K8-Series’s 8-port Copper port module, model 6K8-RJ45, provides eight 10/100Mb switched RJ-45 ports. The 10/100Mb switched ports normally (as a default setting) are independently N-way auto-negotiating, and auto-crossover(MDIX) for operation at 10 or 100Mb speed in fullor half-duplex mode, i.e., each independently selects a mode and speed to match the device at the other end of the twisted pair cable.

(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will automatically determine the other side of connection to make the connection, and eliminate the need of cross-over cable.

www . GarrettCom . com

14

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

On the model 6K8-RJ45 module, there are four LEDs for each port, two in the

connector and two separate. The LK (Link) LED indicates “ready for operation” on that

port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port

when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb

speed when OFF (when auto-

 

1

3

5

7

 

negotiation is not disabled).

 

 

10/100

 

 

 

 

LK

 

 

 

 

 

The FDX/HDX LED is ON

 

 

 

 

 

ACT

to indicate full-duplex

F/ H

2

4

6

8

 

operation and OFF to indicate

10/100

 

 

 

 

LK

 

 

 

 

 

half-duplex mode. A twisted

F/H

 

 

 

 

ACT

 

 

 

 

 

pair cable must be connected

into an RJ-45 port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port.

Using the 6K16-Series (MNS-6K) management software, the user may disable auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb or 100Mb speed and fullor half-duplex mode per-port as per user requirement. (See Magnum MNS-6K Software Manual for details info.).

2.2.4 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8- port

The PoE (Power-pass-through) RJ-45 ports act similar to regular RJ-45 ports, except they have capability of providing power on each port to power up the PD devices,

 

 

 

 

6KP8-45RJ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

per the IEEE802.3af PoE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

standard. The Power Pass-

8 Port@ 10/100Mb Copper ports

 

 

 

 

 

 

 

 

 

 

 

 

 

 

through PoE modules are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

totally dependent upon the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

powerful -48VDC input

 

 

 

1

 

3

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

10/10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LK/AC

 

 

 

 

 

 

power supply to support

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POE

 

 

 

 

 

 

 

more RJ-45 (10/100)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F/ H

2

 

4

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LK/AC

 

 

 

 

 

 

 

ports. Each port requires

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

3

atleast 15watts to power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

up the PoE PD devices.

 

 

F/H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POE

1

LK/ACT

2

10/10

 

 

 

 

 

 

 

 

 

Maxm. one PoE modules

 

LINK

 

 

 

 

 

 

 

 

 

can be configured in the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

PoE

 

 

 

4

 

FULL/HALF

 

 

 

 

 

 

 

A, B slot of any 6K16 s

 

 

 

 

 

 

 

 

 

 

 

 

with -48vdc power input.

The PoE modules are also available with mix –n-match with fiber modules. Please check the ordering information Sec.1.2 for all the various P6K PoE modules option.

www . GarrettCom . com

15

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when connected properly to a 803.af compliant PD device on that port. When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data traffic is not affected by PoE.

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK/ACT, as shown in the diagram.

2.2.5 Six-Port “4 + 2” Combo Modules, 4@ 10/100 RJ-45 and 2@ 100Mb fiber

The combo six-port modules are combinations of copper and fiber media, available as four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-mode fiber ST,

 

1

 

3

5

7

 

10/100

 

 

 

 

 

LK

F/H

 

 

 

 

 

ACT

ACT

 

 

ACT

 

 

F/H

 

 

F/H

 

 

 

2

TX

LK RX

6

TX

LK

RX

 

1

 

3

5

7

 

10/100

 

 

 

 

 

LK

F/H

 

 

 

 

 

ACT

ACT

 

 

ACT

 

 

F/H

 

 

F/H

 

 

 

2

TX

LK RX

6

TX

LK

RX

SC or single mode SC or Long Reach SC ports. For ports numbering, ports 1,3,5,7 are copper, ports 2 and 6 are fiber, ports 4 and 8 are not present.

The four RJ-45 ports operate just like the 8-port copper module with auto-cross (MDIX) feature to eliminate the use of cross-over cable, and the two fiber ports operate at 100Mbps full-duplex (default). User mode control per port through the MNS software is also the same.

On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port, which indicate status the same as described for the 6K8-RJ45 in Section 2.2.3 above. The fiber port’s LEDs indicate status the same way as described for the SFF fiber modules in Section 2.2.2 above. Color-coding on the panel of the module shows which LEDs belong to which port.

 

1

 

3

5

7

 

10/100

 

 

 

 

 

LK

F/H

 

 

 

 

 

ACT

ACT

 

 

ACT

 

 

F/H

 

 

F/H

 

 

 

2

TX

LK RX

6

TX

LK

RX

The Magnum Combo sixport modules are also available with 4@ MTRJ 100Mb mm SFF fiber and 2@10Mb fiber mm ST ports, and with 4@ RJ45 10/100 copper and 2@10Mb fiber mm ST ports. The

4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of the module is as described for those port types above. For detailed information about 10Mb mm ST fiber half of the module, see Section 2.2.5.

www . GarrettCom . com

16

Loading...
+ 51 hidden pages