GarrettCom 20X User Manual

Magnum 200X
Two-Port Repeaters
Corporate Headquarters
Garrett Communications
Phone (510) 438-9071
FAX (510) 438-9072 WWW: http://www.garrettcom.com
email: support@garrettcom.com
Magnum 200X
eu
GARRETT
PWR RX COL JAB
i
GARRETT
­+
PWR [12VDC, 1A]
Magnum 20X
Two-Port Repeater
FWD
FWD
LINK
I
X
GARRETT
Installation and User Guide
GARRETT
Magnum 200X Two-Port Repeaters Installation and User Guide (04/99)
Magnum 200X
Two-Port Repeaters
Installation and User Guide
Part #: 84-00022 (R04/99)
Trademarks Ethernet is a trademark of Xerox Corporation Velcro is a trademark of Velcro U.S.A. UL is a registered trademark of Underwriters Laboratories Magnum is a trademark and Personal Hub is a registered trademark of Garrett
Communications, Inc.
Important: Magnum 200X Two-Port Repeaters contain no user serviceable parts. Attempted service by unauthorized personnel shall render any and all warranties null and void. If problems are experienced with a Magnum 200X, consult Section 5, Troubleshooting, of this User Guide.
1999 Garrett Communications, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Garrett Communications, Inc.
Printed in the United States of America.
GARRETT
Magnum 200X Two-Port Repeaters Installation and User Guide (04/99)
Contacting Garrett Communications
Please use the mailing address, phone and fax numbers, and Internet address listed below.
Garrett Communications
Fremont, CA 94539
Phone (510) 438-9071
Fax (510) 438-9072
WWW: http://www.garrettcom.com
email: support@garrettcom.com
Federal Communications Commission
Radio Frequency Interference Statement
This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference
GARRETT
Magnum 200X Two-Port Repeaters Installation and User Guide (04/99)
TABLE OF CONTENTS PAGE
1.0 SPECIFICATIONS ............................................................................................................1
1.1 Technical Specifications............................................................................................1
1.2 Specifications - Repeater Port Module (RPM)......................................................3
1.3 Ordering Information.................................................................................................3
2.0 INTRODUCTION............................................................................................................4
2.1 Inspecting the Package and Product..........................................................................4
2.2 Product Description.................................................................................................4
2.2.1 Magnum 200X Chassis .................................................................................5
2.3 Magnum 200X - Repeater Port Modules (RPMs)..................................................6
2.3.1 RPM-BNC....................................................................................................7
2.3.2 RPM-TP (Twisted Pair)..........................................................................7
2.3.3 RPM-AUI.....................................................................................................9
2.3.4 RPM-FST (Fiber ST, Twist-lock Connector)..........................................10
2.3.5 RPM-FSC (Fiber SC, Snap-in Connector) **.......................................11
2.3.6 RPM-SMF (Single Mode Fiber)...............................................................11
2.3.7 RPM-DTE...................................................................................................12
2.4 Features and Benefits..............................................................................................13
2.5 Applications............................................................................................................14
3.0 INSTALLATION............................................................................................................16
3.1 Locating the Magnum 200X Two-Port Repeater...................................................16
3.1.1 Magnum 200X Table-Top / Shelf Mounting..............................................16
3.3 Connecting Ethernet Media.....................................................................................16
3.3.1 Connecting Twisted Pair (RJ-45, Unshielded or Shielded).........................17
3.3.2 Connecting ThinNet 10BASE2 (BNC)......................................................17
3.3.3 Connecting ThickNet 10BASE5 (AUI)......................................................18
3.3.4 Connecting Drop Cable 10BASE5 (DTE)..................................................18
3.3.5-6 Connecting Fiber Optic (ST and SC types) ** ......................................18
3.3.7 Connecting Single-Mode Fiber Optic (SMF)..............................................19
3.4 Exchanging RPMs...................................................................................................20
3.4.1 Exchanging RPMs in the Magnum 200X....................................................20
4.0 OPERATION..................................................................................................................22
4.1 Repeater Functionality............................................................................................22
4.2 Powering the Magnum 200X..................................................................................23
4.4 Chassis LEDs..........................................................................................................23
5.0 TROUBLESHOOTING..................................................................................................24
5.1 Before Calling for Assistance..................................................................................25
5.2 When Calling for Assistance...................................................................................25
5.3 Return Material Authorization (RMA) Procedure.................................................26
5.4 Shipping and Packaging Information.......................................................................26
APPENDIX A: W ARRANTY INFORMATION....................................................................27
APPENDIX B: 48VDC SUPPLY ADDENDUM (MODEL 210X ONLY)***..................27
CHANGES MADE IN THIS REVISION ***
GARRETT
Magnum 200X Two-Port Repeaters Installation and User Guide (04/99)
The Magnum Line
ETHERNET CONNECTIVITY PRODUCTS
"DESIGNED AND MANUFACTURED IN THE USA"
OVERVIEW
Garrett Communications offers the Magnum line of Ethernet LAN connectivity products with industry-standard functionality. Magnum products are available worldwide through OEMs, network integrators, representatives, and international distributors.
Fiber Switches, 10/100 Quad-Series, Mixed-Media, 8 & 16­ports
Dual-Speed 8-port, 16-port Stackables, 10/100 auto-sensing/port Fiber Hubs, Dual-speed Mixed-Media, for fiber-to-the desktop Stackable Hubs, SNMP Optional
10Mb series and 100Mb series, both w/ optional port modules
Switching Hubs, unmanaged 500-series and managed 10Mb 5000s Two-Port Switches
100Mb RJ-45 port +10 /100Mb port, or +FDX fiber port Workgroup Hubs 10Mb series and 100Mb series, both w/ optional port modules
Personal Hubs, 100Mb series 8-port dual-speed, 6-port @100 with one switched 10/100Mb Personal Hubs, 10Mb series 8-port +AUI, stackable to 5 high, +optional BNC or fiber port
8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, including multi-mode and single-mode fiber
10 Mb, all media combinations, incl. Fiber/twisted pair/BNC 100Mb, all fiber port types, incl SC, ST, MTRJ, VF45, FX/SX
The “X-line” of configurable MiXed Media 10Mb products: Stackable Concentrators, SNMP optional, 13-Ports Mini-Concentrators, 7 Ports, Repeaters, 2-Ports
Repeater Port Modules (RPMs), 6 types for Ethernet media Bridge Port Modules (BPMs),4 types, for segment isolation
GARRETT
Magnum 200X Two-Port Repeaters Installation and User Guide (04/99)
Workgroup Bridges, 10Mb series Fan-Outs, 10Mb series
4 and 8 Port Deluxe, 2 and 4 Port Standard Models Transceivers, 10Mb series Mini -Transceivers and Coax Models, All Types April’ 99
GARRETT
Data Rate: 10 Mbits / sec Partitioning: Enforced after 32 consecutive collisions. Reconnect: Occurs after 512 bits of error-free transmission.
Network Standards Ethernet V 1.0/V2.0 IEEE 802.3: 10BASE-T, 10BASE5, 10BASE2,
10BASE-FL & FOIRL, and DTE (The Magnum 200X Two-Port Repeaters are physical layer
standard Ethernet products, and operate independently of all software.)
Maximum Ethernet Segment Lengths DTE (AUI Drop Cable) - 50 m (164 ft) 10BASE-T (twisted pair) - 100 m (328 ft)
Shielded twisted pair - 150m (492 ft) 10BASE2 ThinNet (BNC) - 185 m (607 ft) 10BASE5 ThickNet - 500 m (1,640 ft) FOIRL multi-mode Fiber optic - 1 km (3,281 ft) 10BASE-FL multi-mode Fiber optic - 2 km (6,562 ft)
Single-mode Fiber optic - 10 km (32,810 ft)
Connectors 200X: Two Magnum RPM ports on the front, AC power in rear. RPMs available with standard 200X models: RPM -TP: Shielded female RJ-45 with up-link switch
(Note: Shielded 10BASE-T connectors accept either unshielded or
shielded wiring plugs for standard twisted pair media wiring.)
RPM -BNC: ThinNet (BNC) connector with internal termination switch RPM -AUI: D-Sub 15-Pin Female with slide lock RPM -FST: Multi-mode fiber 10BASE-FL ST (dual "twist lock") connector
Ambient Temperature: 32° to 120° F (0° to 50°C) Storage Temperature: -5° to 140°F (-20°to 60°C) Ambient Relative Humidity: 10% to 95% (non-condensing)
Packaging 200X: Enclosure: High strength steel.
Suitable for wiring closet shelf or desktop mounting. (Rack-mount brackets are available as an option) Repeater Port Module Slots: 2 Dimensions: 5.4 in D x 8.5 in. W x 1.75 in. H (13.7 cm x 21.6 cm x 4.45 cm) Weight: 2.5 lbs (1.1 Kg) Port Slot Cut-out: 2.2 in. x .75 in. (5.6 cm x 1.9 cm) Cooling method: Convection
Magnum 200X Power Supply (Internal)
AC Power Connector: IEC-type, male recessed, rear of chassis Input Voltage: 90 to 260 vac (auto -ranging) Input Frequency: 47 to 63 Hz (auto -ranging)
Power Consumption: 15 watts max for the 200X Repeater unit
LED Indicators on Chassis
200X:
PWR - Power, Green LED, steady ON indicates there is AC power. RX - Receive, Green LED, blinks to indicate network activity, data
being received from any of the RPMs. JAB - Jabber, Amber LED, illuminates when jabber condition (illegal
Warranty
Three years, return to factory Made in USA
1.2 Specifications - Repeater Port Modules (RPMs)
RPM Type : BNC AUI DTE Fiber-mm Fiber-sgl.m TP* Front Access yes yes yes yes yes yes Connector Type BNC-f DB-15 f DB-15 m Fiber-ST Fiber-ST RJ-45 Partitio n (PART)LED yes yes yes yes yes yes Receive (RX) LED yes yes yes yes yes yes LINK LED n.a. n.a. n.a. yes yes yes Switch on Face Plate yes** n.a. n.a. n.a. n.a. yes***
“Fiber-mm” is multi-mode cable, normally used for 10BASE -FL installations, up to
2.0km. “Fiber-sgl.m” is single-mode cable, used for distant installations, up to 10.0Km. * The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring. ** Internal termination switch for BNC, no "T" connector is required. *** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 uplink,
no crossover cable is required.
1.3 Ordering Information
Magnum 200X-AT 1 AUI and 1 TP port
Magnum 200X-TT 2 TP ports Magnum 200X-BF 1 BNC and 1 fiber port
Magnum 200X-AF 1 AUI and 1 fiber port Magnum 200X-TF 1 TP and 1 fiber port Magnum 200X-FF 2 fiber ports
Magnum 200X Spare Parts
Magnum 200X Base chassis with 2 RPM slots, internal auto-ranging P.S Magnum RPM-BNC Module with 1 BNC connector + internal term sw, uses 1slot Magnum RPM-TP Module with 1 RJ-45 connector + up -link sw, uses 1 slot Magnum RPM-AUI Module with 1 AUI connector with slide locks, uses 1 slot Magnum RPM-DTE Module with 1 DTE connector with lock posts, uses 1 slot Magnum RPM-FST Module with 1 Fiber ST dual connector, uses 1 slot
Magnum RPM-FSM Module with 1 Fiber SMA dual connector, uses 1 slot
Note: All RPMs are interchangeable for use with other Magnum X-Line products and for bonus port configuration of Magnum Stackable and Workgroup Hubs.
Garrett Communications reserves the right to change specifications, performance characteristics and/or model offerings without notice.
2.0 INTRODUCTION
2.1 Inspecting the Package and Product
Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage which you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Loading...
+ 26 hidden pages