D00001685 Rev 0.4 D52M SoC ANT Module OEM/Integrators Installation Manual / Data sheet DRAFT © 2016 Dynastream Innovations Inc. or its affiliates
1
1
Module Pictures
D52M ANT SoC Module
ANT® Operation (using the latest s212 or s332 SoftDevice)
Module Hardware
Integrated printed antenna On-board 32MHz and 32.768 kHz crystal clocks 1.7V to 3.6V supply voltage range: Operating temperature: Industrial (-40°C to +85°C) Up to 24 GPIOs Programmable output/channel from -20dBm to 4dBm Excellent receiver sensitivity
-93dBm (ANT mode)
-96dBm (BLE mode)
1dBm resolution RSSI Total 512kB flash, 64kB RAM SPI, I ARM SWD interface Internal DC/DC converter supported 14 x 9.8 x 2.0mm module Layout compatible options with N5150M8CD,
Radio regulatory approval for major markets BLUETOOTH SIG qualification RoHS compliant Preloaded with an ANT Network Processor application
2
C and UART interfaces
N550M8CC, N548M8CB
and SoftDevice.
79 selectable RF channels (2402 to 2480 MHz) Flexible network topologies: peer-to-peer, star, tree,
high node count, mesh and more
Broadcast, acknowledged, and burst data
communication modes
Built-in device search and pairing Built-in interference handling and radio coexistence
management with application radio disable requests and application flash write/erase requests
Enhanced ANT features:
o Supports up to 15 logical channels each with
configurable channel periods (5.2ms - 2s)
o Advanced burst data transfer modes (up to
60kbps)
o Optional channel encryption mode (aes-128) o Supports up to 8 public, private and/or managed
networks
o Advanced power management features to
optimize application power consumption including Event Filtering and Selective Data Updates
o Asynchronous transmit channel o Fast channel initiation
Bluetooth®
the latest S132 or S332 SoftDevice)
Bluetooth 4.2 compliant low energy single-mode
protocol stack suitable for Bluetooth low energy products
o Concurrent Central, Observer, Peripheral, and
o Link layer o L2CAP, ATT, and SM protocols o GATT and GAP APIs o GATT Client and Server
low energy operation (when loaded with
Broadcaster roles with up to:
Multiple connections as a central One connection as a peripheral Observer Broadcaster
In certain configurations; See section 2.2 for complete
details
D00001685 Rev 0.4 D52M SoC ANT Module OEM/Integrators Installation Manual / Data sheet DRAFT © 2016 Dynastream Innovations Inc. or its affiliates
Table of Contents
D52M ANT SoC Module ......................................................................................................................................................... 1
Table of Figures ..................................................................................................................................................................... 4
List of Tables .......................................................................................................................................................................... 4
Notices and Restricted use Information ............................................................................................................................. 5
One Year Limited Warranty .................................................................................................................................................. 6
1 D52 ANT SoC Module Series Overview ....................................................................................................................... 7
1.1 Nomenclature ............................................................................................................................................... 8
1.2 Production Tracking Code ............................................................................................................................. 8
1.3 D52 ANT SoC Module Starter Kit and Components ......................................................................................... 9
2 Product Overview ...................................................................................................................................................... 10
2.1 Block Diagrams .......................................................................................................................................... 10
2.2 Pin-outs ..................................................................................................................................................... 10
2.3 Preloaded Software .................................................................................................................................... 11
2.4 D52 Module Programming ........................................................................................................................... 12
2.4.1 Programming via SWD interface .................................................................................................... 12
2.4.2 Initializing the SoftDevice ............................................................................................................. 12
2.4.3 Configuring the dc/dc converter .................................................................................................... 12
2.5 Design considerations ................................................................................................................................. 12
2.5.1 M8 (D52M) module mounting ....................................................................................................... 13
2.6 Assembly Considerations ............................................................................................................................. 13
2.6.1 Moisture Control ........................................................................................................................... 13
2.6.2 Cleaning Process .......................................................................................................................... 13
3 Regulatory Approvals and Compliance ................................................................................................................... 14
3.1 United States ............................................................................................................................................. 14
3.2 Canada ...................................................................................................................................................... 14
3.3 European Economic Area ............................................................................................................................ 14
3.4 Australia and New Zealand .......................................................................................................................... 14
3.5 Japan ......................................................................................................................................................... 15
3.6 Korea ......................................................................................................................................................... 15
3.7 BLUETOOTH Qualification ........................................................................................................................... 15
4 Licensing & Conditions of Use .................................................................................................................................. 15
4.1 Conditions of Use ....................................................................................................................................... 15
4.2 SoftDevice Licensing ................................................................................................................................... 15
5 Electrical Specifications ............................................................................................................................................ 15
5.1 Recommended Operating Conditions ........................................................................................................... 15
5.2 Absolute Maximum Ratings ......................................................................................................................... 16
Page 3 of 18 D00001685 - D52M SoC ANT Module Draft Data Sheet rev 0.4
5.3 Radio Operation Specifications and Antenna Characteristics.......................................................................... 16
5.4 Electrical Specifications ............................................................................................................................... 16
6 Mechanical Drawings ................................................................................................................................................ 16
6.1 D52M ......................................................................................................................................................... 16
7 Support ...................................................................................................................................................................... 16
7.1 ANT Forum................................................................................................................................................. 16
7.2 Technical References .................................................................................................................................. 17
7.3 ANT Developer’s Zone ................................................................................................................................ 17
7.4 ANT and ANT+ Social Media ....................................................................................................................... 17
Appendix A – Using the ANT Network Processor Configuration .................................................................................... 18
Appendix B – D52 Module Pre-Loaded Software Versions ............................................................................................. 18
dynastream.com thisisant.com
Page 4 of 18 D00001685 - D52M SoC ANT Module Draft Data Sheet rev 0.4
Table of Figures
Figure 1: D52 Module Series Nomenclature ................................................................................................. 8
Figure 2: Production Tracking Code ............................................................................................................ 8
Figure 3: D52MD2M8IA Block Diagram ...................................................................................................... 10
Figure 4: D52M M8 Bottom View ............................................................................................................... 10
Figure 5: Memory Map of the Preloaded Software...................................................................................... 12
List of Tables
Table 1: D52 ANT SoC Module Starter Kit .................................................................................................... 9
Table 2: D52 Module Series Pin-Out .......................................................................................................... 11
Table 3: SoftDevice Licensing and Downloads ........................................................................................... 15
Table 5: Recommended Operating Conditions ........................................................................................... 15
Table 4: Absolute Maximum Ratings ......................................................................................................... 16
Table 6: Current Consumption of Radio Operation ..................................................................................... 16
dynastream.com thisisant.com
Page 5 of 18 D00001685 - D52M SoC ANT Module Draft Data Sheet rev 0.4
Notices and Restricted use Information
Information contained in this document is provided only for your ("Customer" or “you”) convenience and may be superseded by updates. It is your responsibility to ensure that your application meets with your specifications.
Dynastream Innovations Inc. ("DYNASTREAM") makes no representations or warranties of any kind whether express or implied, written or oral, statutory or otherwise, related to the information, including but not limited to its condition, quality, performance, merchantability or fitness for purpose. DYNASTREAM disclaims all liability arising from this information and its use.
DYNASTREAM does not assume any responsibility for the use of the described ANT module (“the Module(s)”).
DYNASTREAM makes no representation with respect to the adequacy of the module in low-power wireless data communications applications or systems. Any Products using the Module must be designed so that a loss of communications due to radio interference or otherwise will not endanger either people or property, and will not cause the loss of valuable data. DYNASTREAM assumes no liability for the performance of products which are designed or created using the Modules.
The Modules are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the Module could create a situation where personal injury or death may occur. If you use the Modules for such unintended and unauthorized applications, you do so at your own risk and you shall indemnify and hold DYNASTREAM and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that DYNASTREAM was negligent regarding the design or manufacture of the Product.
The information disclosed herein is the exclusive property of DYNASTREAM, and is not to be reproduced and/or distributed without the written consent of DYNASTREAM. No part of this publication may be reproduced or transmitted in any form or by any means including electronic storage, reproduction, execution or transmission without the prior written consent of DYNASTREAM. The recipient of this document by its retention and use agrees to respect the security status of the information contained herein.
DYNASTREAM believes the information contained herein is correct and accurate at the time of its release. However, the information contained in this document is subject to change without notice and should not be construed as a commitment by DYNASTREAM unless such commitment is expressly given in a covering document.
The D52 Series of modules have been designed to support the ANT and/or certified for use in many geographic regions around the globe. However, a product incorporating the D52 series module may carry the certification IDs of the module only if it complies with the restrictions and terms, including use of Dynastream-approved software, provided in the conditions of use available at:
www.dynastream.com/components/d52/conditions-of-use
Bluetooth
®
low energy Protocols and are
dynastream.com thisisant.com
Page 6 of 18 D00001685 - D52M SoC ANT Module Draft Data Sheet rev 0.4
One Year Limited Warranty
This D52 Module is warranted to be free from defects in materials or workmanship for 1 year from the date of purchase by the end customer. Within this period, Dynastream will, at its sole option, replace any D52 Modules that fail in normal use. Replaced D52 Modules have a 1 year warranty. Dynastream retains the exclusive right to replace (with a new or newly­overhauled replacement product) the D52 Module or offer a full refund of the purchase price at its sole discretion. SUCH REMEDY SHALL BE THE SOLE AND EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY. Such replacement will be made at no charge to LICENSEE, provided LICENSEE shall be responsible for any transportation cost. This warranty does not apply to: (i) cosmetic damage, such as scratches, nicks and dents; (ii) damage caused by accident, abuse, misuse, water, flood, fire, or other acts of nature or external causes; (iii) damage caused by service performed by anyone who is not an authorized service provider of Dynastream; or (iv) damage to a D52 Module that has been modified or altered without the written permission of Dynastream. In addition, Dynastream reserves the right to refuse warranty claims against D52 Modules used in contravention of the laws of any country.
THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ANY LIABILITY ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, STATUTORY OR OTHERWISE.
IN NO EVENT SHALL DYNASTREAM BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM THE USE, MISUSE, OR INABILITY TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT.
To obtain warranty service, LICENSEE shall contact Dynastream for shipping instructions and obtain a return material authorization (RMA) tracking number. LICENSEE shall securely pack the D52 Modules and enclose a copy of the original sales receipt, which is required as the proof of purchase for a warranty claim, and write the tracking number clearly on the outside of the package. LICENSEE agrees to send the D52 Modules, freight charges prepaid, to the Dynastream address provided in the Module Distribution Agreement (see www.dynastream.com/components/d52/conditions-of-use).
©2016 Dynastream Innovations Inc. All Rights Reserved.
dynastream.com thisisant.com
Loading...
+ 12 hidden pages