Garland Ongard OG10 User Manual

ATTENTION: Please take a few minutes to thoroughly read this user guide which should be saved for future reference and passed on to any subsequent owner.
Ionisation Smoke Alarm with Hush User Guide
240V AC, 50Hz, 80mA max, 9V back up, single and or multiple station (18 units maximum)
Model: OG10
Contents of This User Guide
1. Product Features 3
2. Product Specifications
4
3. Installation Instructions
5
4. Locations To Avoid
8
5. Wiring Instructions
9
6. Mounting Instructions
11
7. Operation And Test
12
8. Alarm Nuisance and Hush
14
9. Troubleshooting
15
10. Battery Replacement
16
11. Cleaning Your Alarm
17
12. Limitations Of Smoke Alarms
17
13. Good Safety Habits
18
14. What To Do When the Alarm Sounds
19
15. Warranty & Contact Details
20
Thank you for purchasing this smoke alarm. It is an important part of your family’s home safety plan. You can trust Garland OnGard to provide the highest quality safety products.
Please take a few minutes to thoroughly read this user guide, and save it for future reference. Teach children how to respond to the alarms, and that they should never play with the unit.
If you have any enquiries regarding this product please visit our website: www.garlandcables.com.au
3
1. Product Features
Model OG10 is powered from a 240V AC supply, and has a DC battery back-up source. AC/DC smoke alarms offer added protection in the event of a power failure. Unique power connector prevents interconnecting with incompatible smoke alarms, CO alarms, heat alarms, or security systems. The smoke alarm can be interconnected with up to 17 other Garland OnGard models as set out in Section 2 – Product Specifications. Do not connect to any other type or model of smoke, CO, or heat alarm.
• Hush quiets unwanted alarms for up to 10 minutes
• Alarm memory identifies which alarm has activated
• Optional use tamper-resistant feature serves as a safeguard against tampering
• The smoke alarm will sound a short beep about once every 40 seconds if the battery is low
• Multi-purpose green and red LEDs indicate that the smoke alarm is connected to the AC supply, is working normally, or is in alarm
• Loud alarm sounder – 85 dB
• Test button checks smoke alarm operation
WARNING! REMOVAL OF SMOKE ALARM BATTERY AND DISCONNECTING OR LOSS OF AC POWER WILL RENDER THIS UNIT INOPERATIVE.
DO NOT TRY TO REPAIR THIS SMOKE ALARM YOURSELF.
4
2. Product Specifications
Model
OG10
Electrical Rating 240V AC 50HZ, DC battery back up
(9V battery )
Sensor Ionisation Smoke Sensor
Interconnecting Smoke and Heat Alarms
Up to any combination of 17 other alarm models. Compatible Models include:
OG10
, OG20, OG20LL, OG30.
Operating Temperature 0°C to 40°C
Operating Humidity Up to 93% Humidity (Non-Condensing)
Lound Alarm 85 decibels at 3 metres
Models OG10 are designed to detect products of combustion using ionisation technology. This product contains 0.9 microcurie of Americium 241, a radioactive material.
5
3. Installation Instructions
This smoke alarm must only be wired to a 240VAC 50Hz sine wave current supply.
Laws on smoke alarms vary from state to state and you should be aware of what the requirements are in the state you live - for more information please refer to your local fire emergency services.
Recommended Locations
• In every room where someone sleeps with the door closed. The
closed door may prevent an alarm located outside from waking the sleeper.
• In the immediate area of bedrooms and the exit path from all sleeping
areas (Figure 1A).
• In stairways, as stairways act like chimneys for smoke and heat.
• In any room where large electrical appliances are operated
(e.g. portable heaters or humidifiers).
• If a hallway or room is more than 9.1m long put alarms at both ends.
• For maximum household protection see Figure 1C.
Things to Consider:
For Ceiling Mounting:
Smoke from a fire will rise to the ceiling and spread horizontally. Mounting the smoke alarm in the centre of the ceiling places it closest to all points in the room.
• When mounting an alarm on the ceiling, locate it at a minimum of
300mm from the side wall (Figure 2A).
• For sloped, peaked or cathedral ceilings the alarm should be placed
between 500mm and 1500mm from the highest point of the ceiling (Figure 2B).
• Smoke alarms in rooms with ceiling slopes greater than 1m in 8m
horizontally, should be located on the high side of the room (Figure 2B).
For Wall Mounting:
• When mounting the alarm on the wall, use an interior wall with the
top edge of the alarm at a minimum of 100mm and a maximum of 600mm below the ceiling (Figure 2A).
6
3. Installation Instructions
DINING
ROOM
LIVING
ROOM
Smoke Alarms for Minimum Protection
Ionisation Type Smoke Alarm with Alarm Silencer (Hush) or Photoelectric Type
Smoke Alarms for Additional Protection
KITCHEN BEDROOM
BEDROOM
BEDROOM
LIVING ROOM
KITCHEN
BEDROOMBEDROOMHALL
BASEMENT
FIGURE 1A
FIGURE 1B
SINGLE FLOOR PLAN
MULTIPLE FLOOR PLAN
or Heat Alarm
DINING
ROOM
LIVING
ROOM
Smoke Alarms for Minimum Protection
Ionisation Type Smoke Alarm with Alarm Silencer (Hush) or Photoelectric Type
Smoke Alarms for Additional Protection
KITCHEN BEDROOM
BEDROOM
BEDROOM
LIVING ROOM
KITCHEN
BEDROOMBEDROOMHALL
BASEMENT
FIGURE 1A
FIGURE 1C
FIGURE 1B
SINGLE FLOOR PLAN
MULTIPLE FLOOR PLAN
BEDROOM
FAMILY ROOM
WORKSHOPBASEMENT
KITCHEN
HALL
GARAGE
MASTER
BEDROOM
FIRE EXTINGUISHERS
SMOKE ALARMS
FIRE BLANKET
TOTAL HOME PROTECTION
or Heat Alarm
7
3. Installation Instructions
Smoke alarm should be located between 500mm and 1500mm of the highest point.
FIGURE 2A
CEILING
300mm
MINIMUM
600mm
MINIMUM
MAXIMUM
SIDE WALL
BEST
PLACEMENT
DO NOT INSTALL
DEAD AIR
ACCEPTABLE
PLACEMENT
100mm
FIGURE 2A
CEILING
PEAK CEILING
300mm
MINIMUM
600mm
MINIMUM
MAXIMUM
SIDE WALL
BEST
PLACEMENT
DO NOT INSTALL
DO NOT INSTALL
DEAD AIR
NOT IN THIS AREA
ANYWHERE IN THIS AREA
500mm
1000mm
DEAD AIR
ACCEPTABLE
PLACEMENT
100mm
CEILING
PEAK CEILING
MINIMUM
600mm
MINIMUM
MAXIMUM
SIDE WALL
BEST
PLACEMENT
DO NOT INSTALL
DO NOT INSTALL
DEAD AIR
NOT IN THIS AREA
ANYWHERE IN THIS AREA
500mm
1000mm
DEAD AIR
ACCEPTABLE
PLACEMENT
100mm
FIGURE 2B
DEAD AIR
DO NOT INSTALL
SLOPED CEILING
NOT IN THIS AREA
500mm
ANYWHERE IN THIS AREA
1000mm