Garland E22-36-36GMX, E22-36-45GMX, E22-36-48GMX, E22-36-56GMX, E22-36-60GMX Operation Manual

...
INSTALLATION AND
OPERATION MANUAL
GARLAND ELECTRIC
TEPPAN YAKI GRIDDLE
E22-36 SERIES
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
INSTALLATION AND ELECTRICAL CONNECTION
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL
CODE PART 1 AND / OR LOCAL CODES.
IN USA – THE NATIONAL ELECTRICAL CODE
ANSI / NFPA – CURRENT EDITION.
ENSURE ELECTRICAL SUPPLY CONFORMS WITH ELECTRICAL CHARACTERISTICS SHOWN ON
THE RATING PLATE.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
185 East South Street Freeland, Pennsylvania 18224 Phone: (570) 636-1000 Fax: (570) 636-3903
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4 CANADA Phone: 905-624-0260 Fax: 905-624-5669
Enodis UK LTD.
5E Langley Business Centre Station Road, Langley SL3 8DS Great Britain Phone : 01753 485900 Fax: 01753 485901
Part # 4517056 Rev 2 (09/24/08) © 2004 Garland Commercial Industries, Inc.
Part # 4517056 Rev 2 (09/24/08)Page 2
TABLE OF CONTENTS
SPECIFICATION AND INSTALLATION OPTIONS.........................4
Flanged Griddle Installation – Table Cut Sizes ......................................5
GENERAL INFORMATION ............................................6
SAFETY.............................................................6
INSTALLATION......................................................7
Electrical Supply: .................................................................7
Electrical Supply Connection: .....................................................7
Siting: ...........................................................................7
Ventilation: ......................................................................7
General Installation Procedure: ...................................................7
Commissioning: ..................................................................7
MAINTENANCE & CLEANING.........................................8
Electromechanical Bulb and Capillary Thermostat: .................................8
Models Manufactured Prior To September 2003 ...............................8
Electronic Thermostat Models With Spade Type Temperature Control Sensors: .....8
Models Manufactured Since October 2003 ....................................8
Miscellaneous: ...................................................................8
WIRING DIAGRAMS .................................................9
Part # 4517056 Rev 2 (09/24/08) Page 3
SPECIFICATION AND INSTALLATION OPTIONS
Griddle Size With Flange Griddle Size Less Flange Shipping
Model
Width (A) Depth (B) Width (C) Depth (D)
E22-36-36GMX 37-5/8" (957mm) 26-9/16" (675mm) 35-13/16" (910mm) 24-1/4" (616mm) 330/150 E22-36-45GMX 46-15/16" (1192mm) 28-1/4" (718mm) 45-1/8" (1146mm) 26-15/16" (685mm) 340/154 E22-36-48GMX 49-5/8" (1260mm) 26-9/16" (675mm) 47-13/16" (1215mm) 24-1/4" (616mm) 350/159 E22-36-56GMX 58-3/16" (1478mm) 28-1/4" (718mm) 56-3/8" (1432mm) 26-15/16" (685mm) 385/175 E22-36-60GMX 61-5/8" (1565mm) 26-9/16" (675mm) 59-13/16" (1520mm) 24-1/4" (616mm) 385/175 E22-36-72GMX 73-5/8" (1870mm) 26-9/16" (675mm) 71-13/16" (1824mm) 24-1/4" (616mm) 400/182
Wt
lb/kg
The E22-36-36GMX is for installation in non-combustible locations only. All others should be installed with the adjacent minimum clearances from combustible material.
A C
11"
[279mm]
3 1/2"
[89mm]
HOT SPOT AREA
1 9/16"
[29mm]
3/4"
[19mm]
4 3/4"
[121mm]
4 3/4"
[121mm]
STEEL PLATE
REAR CABLE ENTRANCE
34"
[864mm]
BOTTOM CABLE ENTRANCE
36"
[914mm]
FRONT VIEW
D
10"
GARLAND
[254mm]
BOTTOM CABLE
ENTRANCE
Body Side Minimum Installation
Clearances: In/mm
Left & Right
Sides
Rear
1/2 /12-1/2 1/2/121/2 Combustible
1"
[25mm] .5"
B
1/2"
[13mm]
18 1/4"
[464mm]
21 3/8"
[543mm]
[12mm]
.5"
[12mm]
FLANGE
MEASUREMENTS
REAR CABLE ENTRANCE
[44mm]
1 3/4"
Type of Floor
Base
SUGGESTED MOUNTINGS (Not to Scale)
1"
[25mm]
METAL
EXPANSION
STRIP
BY OTHERS
GRILL
BY
GARLAND
MARBLE / SIMILAR NON-COMBUSTIBLE MATERIAL MUST BE 3" [76mm] SIDES & BACK
TABLE TOP MOUNTING
WITH NON- FLANGE EDGE
36" WIDE MODEL (E22-36-36GMX)
3"
[76 mm]
METAL
EXPANSION
STRIP
BY OTHERS
GRILL
GARLAND
TABLE TOP MOUNTING
NON FLANGED EDGE
45" TO 72" MODELS
MINIMUM CLEARANCE TO
COMBUSTIBLE CONSTRUCTION
1" [25mm] SIDES AND BACK
1"
[25mm]
BY
WOODEN TABLE BY OTHERS
EXPANSION STRIP
SUPPLIED BY OTHERS
NON-COMBUSTIBLE
i.e. MARBLE OR SIMILAR
GRILL WITH
FLANGE
TABLE TOP MOUNTING
WITH FLANGED
EDGE OPTION
TABLE TOP
WOOD ect.
Garland products are not approved or Authorized for home or residential use, but are intended for commercial applications only. Garland will not provide service, warranty, maintenance or support of any kind other than in commercial applications.
Part # 4517056 Rev 2 (09/24/08)Page 4
SPECIFICATION AND INSTALLATION OPTIONS continued
Models E22-36-36GM(X) E22-36-45GM(X) E22-36-48GM(X)
E22-36-56GM(X) E22-36-60GM(X) E22-36-72GM(X)
X sux use electronic thermostats
Total kW
Loading
240V 208V
X-Y Y-Z X-Z X-Y Y-Z X-Z X Y Z X Y Z
6.7 6.7 3.35 3.35 3.35 3.35 27.92 32.21 24.22 13.96 13.96 27.95 16.11 16.11
kW Loading Per Phase
Single Phase Three Phase
240V 208V
240V 208V
Nominal Amps Per Phase
240V 208V
Flanged Griddle Installation – Table Cut Sizes
Model Shown: E22-36-48GMX
A
49-5/8"
[1260mm]
47-13/16"
[12.15mm]
25-9/16"
[649mm]
Minimum
Table
Cut Out
D
26-9/16"
[675mm]
B
1-1/8"
[29mm]
25-3/16"
[640mm]
48-3/8"
[1229mm]
Minimum
Table Cut Out
GRILL PLATE
DIMENSIONS ARE
-1/16", +0
C
Recommended table cut out
MODEL A B C D
E22-36-36GMX 37-5/8" (957mm) 26-9/16" (675mm) 36-3/8" (934mm) 25-9/16" (649mm) E22-36-45GMX 46-15/16" (1192mm) 28-1/4" (718mm) 45-11/16" (1160mm) 27-1/4" (692mm) E22-36-48GMX 49-5/8" (1260mm) 26-9/16" (675mm) 48-3/8" (1229mm) 25-9/16" (649mm) E22-36-56GMX 58-3/16" (1478mm) 28-1/4" (718mm) 56-15/16" (1445mm) 27-1/4" (692mm) E22-36-60GMX 61-5/8" (1565mm) 26-9/16" (675mm) 60-3/8" (1534mm) 25-9/16" (649mm) E22-36-72GMX 73-5/8" (1870mm) 26-9/16" (675mm) 72-3/8" (1828mm) 25-9/16" (649mm)
Part # 4517056 Rev 2 (09/24/08) Page 5
GENERAL INFORMATION
1. Check the crate for possible damage sustained during transit. Carefully remove the unit from the crate and again check for damage. Any damage to the appliance must be reported to the carrier immediately.
2. The type of voltage supply that the equipment was manufactured for at the factory is noted on the data plate on the equipment. This type of supply must be used.
SAFETY
t "RVBMJöFEQFSTPONVTUNBLFUIFJOTUBMMBUJPOJO
accordance with the authority having jurisdiction and local codes.
t 5IJTVOJUNVTUPOMZCFPQFSBUFECZBRVBMJöFEQFSTPO%0
NOT operate without reading this manual.
t %0/05PQFSBUFUIJTBQQMJBODFVOMFTTBMMTFSWJDFBOE
access panels are in place and fastened properly.
3. Do not remove permanently axed labels, warning or data plates form the appliance, this may void approvals and create a safety hazard.
The Garland E22 series complies with the standards CSA C22.2 no. 109 – latest edition and UL197 – latest edition. The installation and connection of this appliance must comply with current codes. In Canada – the Canadian Electrical Code Part 1 and in the USA – the National Electrical Code.
t %0/05DMFBOUIJTBQQMJBODFVOMFTTUIFQPXFSTVQQMZJT
disconnected.
WARNING: To avoid serious personal injury:
t 64&&953&.&$"65*0/JOTFUUJOHVQPQFSBUJOHBOE
cleaning these appliances to avoid coming in contact with hot surfaces. Wear suitable protective clothing or use proper utensils to prevent the risk of burns.
t %0/05BUUFNQUUPSFQBJSPSSFQMBDFBOZQBSUPGUIJT
appliance unless all main power supplies have been disconnected.
NOTE: All warning labels and markings on this appliance,
which call attention to further dangers and necessary precautions.
Part # 4517056 Rev 2 (09/24/08)Page 6