THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
INSTALLATION AND ELECTRICAL CONNECTION
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL
CODE PART 1 AND / OR LOCAL CODES.
IN USA – THE NATIONAL ELECTRICAL CODE
ANSI / NFPA – CURRENT EDITION.
ENSURE ELECTRICAL SUPPLY CONFORMS WITH
ELECTRICAL CHARACTERISTICS SHOWN ON
THE RATING PLATE.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
WARNING:
This product contains chemicals known to the state of california to cause cancer and/or birth defects
or other reproductive harm. Installation and servicing of this product could expose you to airborne
particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers
is known to the state of California to cause cancer.
Your new equipment should be given regular care and
maintenance. Periodic inspections by your dealer or a
qualied service agency are recommended.
This product has been certied as commercial cooking
equipment and must be installed by professional personnel
as specied.
Uncrating
Carefully remove unit from crate or carton. All packing
material should be removed from units. On stainless steel
units the protective material covering the stainless steel
should be removed.
After uncrating, immediately check the equipment for visible
signs of shipping damage.
INSTALLATION
If such damage has occurred, do not refuse shipment, but
contact the shipper and le the appropriate freight claims.
Rating Plate
When corresponding with the factory or your local
authorized factory service center regarding service problems
or replacement parts, be sure to refer to the particular unit
by the correct model number (including the prex and sux
letters and numbers) and the warranty serial number. The
serial plate is attached to the inside of the control panel of
the lower oven section contains this information.
Before attempting the electrical connection, the rating
pate should be checked to ensure that the unit’s electrical
characteristics and the supply characteristics agree.
Clearances
The 2000 E series ovens must be installed with a minimum
of zero (0”) clearance to the sides and back to walls of
combustible material.
Assembly Instructions
1. Open the bottom section of the crate and the leg crate.
Proceed with oven assembly as follows:
a. Fasten lefts to base using 1/4” hex head bolts, locking
washers and nuts provided.
b. Ensure the insulation is evenly spread and in the
proper position on the top of the lower unit.
c. Place an 1” x 4” x 60” (22mm x 100mm x 1525mm)
long piece of lumber across the rear top of the oven
to prevent the stacks from misaligning.
d. Raise the center of top oven section up and on to the
lower oven section, sliding the oven section forward
until the main sides of the section engage behind the
oven front.
e. Remove the piece of lumber and lower the rear of the
oven section into position.
f. Secure the left and right out side front corners of
the oven section using No. 1-24 x 1/2” at head bolts
supplied.
g. Secure the oven backs using six 10-1/2” truss head
sheet metal screws.
2. To connect the section feed wires to the main oven
terminal block, refer to the wiring diagram attached to
the main terminal block.
3. With the oven(s) in the desired position, use a sprint level
and level unit four ways: across front and back, and down
left and right edges.
4. When two pizza ovens (2001P) are stacked, remove the
top louvers on the bottom oven. Assemble as illustrated
in instructions found with the stacking plates.
Part #4520414 (01/28/08)Page 5
INSTALLATION Continued
DO NOT under any circumstances; connect the vent stack
of the oven directly to the ue pipe or a vent system. If this
is done, it seriously decreases the eciency and will cause
uneven heating of the section. If an outside ue connection
must be made, a suitable hood placed 12” (305mm) above
the oven ue must be provided to prevent direct suction of
the air through the oven sections.
Steam Injection (Optional Extra)
Steam is often used for baking of hard rolls, French bread,
Vienna bread and other hard crust breads. The steam
provided inside the oven is a cloud of atmospheric steam or
water vapor.
One quarter broiler h.p. for each bake deck is required at
the steam inlet of the deck. It is important that the steam
provided to the oven is lower pressure (3 lbs. To 5 lbs per
square inch), (2100 kg/m² to 3500 kg/m²) and condensate
must be drained from the steam line before it enters the
oven.
The steam will be suciently saturated at this pressure to
provide the vapor cloud eect that is needed to cover the
top of the product.
When steam is required in the deck, it is recommended that
the steam valve at the deck is only open a half-turn for 3
to 5 seconds. The time will be determined by the operator.
Allowing too much steam to enter the oven will produce a
soggy product.
Electrical Connections
The installation and connection should comply with current
codes. In Canada - The Canadian Electrical Code Part 1 and/or
local codes. In the U.S.A. - The National Electrical Code ASNA/
NFPA - current edition.
Before attempting the electrical connection, the rating
plate should be checked to ensure that the unit’s electrical
characteristics and the supply characteristics agree.
The unit has been wired as specied on the factory order
and the rating plate is stamped with the information. If it is
necessary to change the phase, refer to the wiring diagram
attached to the main terminal block, or refer to the rating
plate.
Electrical connection may be made though the knockout at
the rear of bottom of the unit to the terminal block located
directly behind the switch panel on the main bottom. Hinge
switch panel open.
For the supply connection use suitable wire for 60° C.
Break-In Procedure
It is strongly recommended that the 2000 Series ovens
supplied with core plates be put through a break-in period
to eliminate possible warpage of the core plates caused by
moisture absorption.
This action need only be carried out once providing the
ovens are used daily, however, if the ovens are left idle for an
extended period of time allowing the core plates to absorb
moisture, the following procedure must be again carried out.
Turn the top and bottom heat selector switched to HI, set the
thermostat to 300°F (149°C) maximum and allow the oven to
operate (without any product in the oven), for approximately
8 hours.
Part # 4520414 (01/28/08)Page 6
OPERATION AND MAINTENANCE
Top and bottom heating units are each operated by a three
heat heavy duty reversible switch. An oven thermostat with
pilot light is also provided. The thermostat maintains the
temperature and the switches determine the source of the
heat.
1 Turn the top heating unit to HIGH.
2 Turn the bottom heating unit to HIGH.
3. Set the oven thermostat to the desired temperature. The
pilot light will now come ON.
4. When the desired temperature is reached, the pilot light
will go OFF. At this time the top heating unit switch may
be turned OFF or set as desired.
5 The bottom heating unit switch may be left at HIGH or
adjusted as desired.
Thermostat Calibration
All electric ovens are equipped with snap action thermostats.
Field calibration is seldom necessary and should not be
resorted to unless experience with cooking results denitely
provides that the control is not maintaining the temperature
to which the dial is set. To check the oven temperature when
calibrating, use only a reliable mercury thermometer or
preferably an oven pyrometer.
2. Turn oven temperature control dial to 400°F (204°C). In
order to allow the oven temperature to stabilize, the oven
control must be allowed to cycle twice before taking a
test reading
3. Check temperature reading control just as it cycles ‘OFF”
as indicated by the cycling pilot. If the temperature doe
not read within 15°F (8°C) of the dial setting, recalibrate
as follows
4. Carefully remove the thermostat dial, not disturbing the
dial setting.
5. Hold the dial shaft steady and with a screwdriver, turn the
calibration screw, located inside the dial shaft clockwise
to decrease and counter-clock wise to increase the
temperature. I.E. 1/4 turn = 35°F (19.5°C).
6. Replace the thermostat dial and repeat steps 1 through 3
to verify that the correct adjustment has been made.
Cleaning of Core Plates
1. Set the thermostat dial to 550°F (288°C) at the end of the
cooking day and allow to cycle for one hour.
2. When the oven has cooled the residue will have
carbonized and can be removed by sweeping with a sti
wire brush.
1. Place the thermocouple of the test instrument or reliable
mercury thermometer in the center of the oven.
3. Stubborn residue can be loosened with a scraper.
Part #4520414 (01/28/08)Page 7
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.