Garland E2001, E2011, E2111, E2005, E2055 Installation And Operation Manual

...
INSTALLATION AND
OPERATION MANUAL
GARLAND 2000 SERIES
ELECTRIC BAKE, ROAST AND
COMBINATION OVENS
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
INSTALLATION AND ELECTRICAL CONNECTION
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL
CODE PART 1 AND / OR LOCAL CODES.
IN USA – THE NATIONAL ELECTRICAL CODE
ANSI / NFPA – CURRENT EDITION.
ENSURE ELECTRICAL SUPPLY CONFORMS WITH ELECTRICAL CHARACTERISTICS SHOWN ON
THE RATING PLATE.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents. For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com. The information contained herein, (including design and parts specifications), may be superseded and is subject to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street Freeland, Pennsylvania 18224 Phone: (570) 636-1000 Fax: (570) 636-3903
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4 CANADA Phone: 905-624-0260 Fax: 905-624-5669
Enodis UK LTD.
Swallow eld Way, Hayes, Middlesex UB3 1DQ ENGLAND Telephone: 081-561-0433 Fax: 081-848-0041
Part # 4520414 (01/28/08) © 2005 Garland Commercial Industries, Inc.
Part #4520414 (01/28/08) Page 1
IMPORTANT INFORMATION
WARNING: This product contains chemicals known to the state of california to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers is known to the state of California to cause cancer.
Part # 4520414 (01/28/08)Page 2
TABLE OF CONTENTS
IMPORTANT INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Loading Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Uncrating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Rating Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Steam Injection (Optional Extra) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Break-In Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
OPERATION AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Thermostat Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cleaning of Core Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Part #4520414 (01/28/08) Page 3
SPECIFICATIONS
Model Description
All models are 55 1/2” wide x 36” deep (1410mm x 914mm)
MODEL HEIGHT DESCRIPTION
E2001 51” (1295mm) Single Deck Bake Oven E2011 66” (1676mm) Double Deck Bake Oven E2111 66” (1676mm) Triple Deck Bake Oven E2005 51” (1295mm) Single Deck Roast Oven E2055 67” (1702mm) Double Deck Roast Oven E2555 78” (1981mm) Triple Deck Roast Oven E2015 63” (1800mm) One Bake and One Roast Combination Oven E2115 70” (1778mm) Two Bake and One Roast Combination Oven E2155 74” (1879mm) One Bake and Two Roast Combination Oven
Loading Charts
LOADING CHART
Total Kw
Model
E2001 6.2 11 15 23 12.5 17.3 26 26 30 E2011 12.4 32 26 32 37 30 37 52 60 E2111 18.6 45 45 45 51.5 51.5 51.5 77.5 90 E2005 6.2 11 15 23 12.5 17.3 26 26 30 E2055 12.4 32 26 32 37 30 37 52 60 E2555 18.6 45 45 45 51.5 51.5 51.5 77.5 90 E2015 12.4 32 26 32 37 30 37 52 60 E2115 18.6 45 45 45 51.5 51.5 51.5 77.5 90 E2155 18.6 45 45 45 51.5 51.5 51.5 77.5 90
Loading
240V &
208V
240V 280V
X Y Z X Y Z 240V 208V
Nominal Amperes Per Phase
3 Phase
Single Phase
Part # 4520414 (01/28/08)Page 4
INTRODUCTION
Your new equipment should be given regular care and maintenance. Periodic inspections by your dealer or a qualied service agency are recommended.
This product has been certied as commercial cooking equipment and must be installed by professional personnel as specied.
Uncrating
Carefully remove unit from crate or carton. All packing material should be removed from units. On stainless steel units the protective material covering the stainless steel should be removed.
After uncrating, immediately check the equipment for visible signs of shipping damage.
INSTALLATION
If such damage has occurred, do not refuse shipment, but contact the shipper and le the appropriate freight claims.
Rating Plate
When corresponding with the factory or your local authorized factory service center regarding service problems or replacement parts, be sure to refer to the particular unit by the correct model number (including the prex and sux letters and numbers) and the warranty serial number. The serial plate is attached to the inside of the control panel of the lower oven section contains this information.
Before attempting the electrical connection, the rating pate should be checked to ensure that the unit’s electrical characteristics and the supply characteristics agree.
Clearances
The 2000 E series ovens must be installed with a minimum of zero (0”) clearance to the sides and back to walls of combustible material.
Assembly Instructions
1. Open the bottom section of the crate and the leg crate. Proceed with oven assembly as follows:
a. Fasten lefts to base using 1/4” hex head bolts, locking
washers and nuts provided.
b. Ensure the insulation is evenly spread and in the
proper position on the top of the lower unit.
c. Place an 1” x 4” x 60” (22mm x 100mm x 1525mm)
long piece of lumber across the rear top of the oven to prevent the stacks from misaligning.
d. Raise the center of top oven section up and on to the
lower oven section, sliding the oven section forward until the main sides of the section engage behind the oven front.
e. Remove the piece of lumber and lower the rear of the
oven section into position.
f. Secure the left and right out side front corners of
the oven section using No. 1-24 x 1/2” at head bolts supplied.
g. Secure the oven backs using six 10-1/2” truss head
sheet metal screws.
2. To connect the section feed wires to the main oven terminal block, refer to the wiring diagram attached to the main terminal block.
3. With the oven(s) in the desired position, use a sprint level and level unit four ways: across front and back, and down left and right edges.
4. When two pizza ovens (2001P) are stacked, remove the top louvers on the bottom oven. Assemble as illustrated in instructions found with the stacking plates.
Part #4520414 (01/28/08) Page 5
INSTALLATION Continued
DO NOT under any circumstances; connect the vent stack of the oven directly to the ue pipe or a vent system. If this is done, it seriously decreases the eciency and will cause uneven heating of the section. If an outside ue connection must be made, a suitable hood placed 12” (305mm) above the oven ue must be provided to prevent direct suction of the air through the oven sections.
Steam Injection (Optional Extra)
Steam is often used for baking of hard rolls, French bread, Vienna bread and other hard crust breads. The steam provided inside the oven is a cloud of atmospheric steam or water vapor.
One quarter broiler h.p. for each bake deck is required at the steam inlet of the deck. It is important that the steam provided to the oven is lower pressure (3 lbs. To 5 lbs per square inch), (2100 kg/m² to 3500 kg/m²) and condensate must be drained from the steam line before it enters the oven.
The steam will be suciently saturated at this pressure to provide the vapor cloud eect that is needed to cover the top of the product.
When steam is required in the deck, it is recommended that the steam valve at the deck is only open a half-turn for 3 to 5 seconds. The time will be determined by the operator. Allowing too much steam to enter the oven will produce a soggy product.
Electrical Connections
The installation and connection should comply with current codes. In Canada - The Canadian Electrical Code Part 1 and/or local codes. In the U.S.A. - The National Electrical Code ASNA/ NFPA - current edition.
Before attempting the electrical connection, the rating plate should be checked to ensure that the unit’s electrical characteristics and the supply characteristics agree.
The unit has been wired as specied on the factory order and the rating plate is stamped with the information. If it is necessary to change the phase, refer to the wiring diagram attached to the main terminal block, or refer to the rating plate.
Electrical connection may be made though the knockout at the rear of bottom of the unit to the terminal block located directly behind the switch panel on the main bottom. Hinge switch panel open.
For the supply connection use suitable wire for 60° C.
Break-In Procedure
It is strongly recommended that the 2000 Series ovens supplied with core plates be put through a break-in period to eliminate possible warpage of the core plates caused by moisture absorption.
This action need only be carried out once providing the ovens are used daily, however, if the ovens are left idle for an extended period of time allowing the core plates to absorb moisture, the following procedure must be again carried out.
Turn the top and bottom heat selector switched to HI, set the thermostat to 300°F (149°C) maximum and allow the oven to operate (without any product in the oven), for approximately 8 hours.
Part # 4520414 (01/28/08)Page 6
OPERATION AND MAINTENANCE
Top and bottom heating units are each operated by a three heat heavy duty reversible switch. An oven thermostat with pilot light is also provided. The thermostat maintains the temperature and the switches determine the source of the heat.
1 Turn the top heating unit to HIGH.
2 Turn the bottom heating unit to HIGH.
3. Set the oven thermostat to the desired temperature. The pilot light will now come ON.
4. When the desired temperature is reached, the pilot light will go OFF. At this time the top heating unit switch may be turned OFF or set as desired.
5 The bottom heating unit switch may be left at HIGH or
adjusted as desired.
Thermostat Calibration
All electric ovens are equipped with snap action thermostats. Field calibration is seldom necessary and should not be resorted to unless experience with cooking results denitely provides that the control is not maintaining the temperature to which the dial is set. To check the oven temperature when calibrating, use only a reliable mercury thermometer or preferably an oven pyrometer.
2. Turn oven temperature control dial to 400°F (204°C). In order to allow the oven temperature to stabilize, the oven control must be allowed to cycle twice before taking a test reading
3. Check temperature reading control just as it cycles ‘OFF” as indicated by the cycling pilot. If the temperature doe not read within 15°F (8°C) of the dial setting, recalibrate as follows
4. Carefully remove the thermostat dial, not disturbing the dial setting.
5. Hold the dial shaft steady and with a screwdriver, turn the calibration screw, located inside the dial shaft clockwise to decrease and counter-clock wise to increase the temperature. I.E. 1/4 turn = 35°F (19.5°C).
6. Replace the thermostat dial and repeat steps 1 through 3 to verify that the correct adjustment has been made.
Cleaning of Core Plates
1. Set the thermostat dial to 550°F (288°C) at the end of the cooking day and allow to cycle for one hour.
2. When the oven has cooled the residue will have carbonized and can be removed by sweeping with a sti wire brush.
1. Place the thermocouple of the test instrument or reliable mercury thermometer in the center of the oven.
3. Stubborn residue can be loosened with a scraper.
Part #4520414 (01/28/08) Page 7