Gardena RP 300, WLP 300 B, WLP 300 S Operating Instructions Manual

GARDENA
®
9 V RP 300 Art. 7836
WLP 300 S Art. 7839 WLP 300 B Art. 7840
D Gebrauchsanweisung
GB Operating Instructions
Indoor Fountain Pump / Water Light Jet Pump 9 V
F Mode d’emploi
Pompe pour fontaines d’intérieur / Pompe pour jets d’eau avec éclairage 9 V
NL Gebruiksaanwijzing
Binnenshuis-fonteinpomp / Water-/ lichtspelpomp 9 V
S Bruksanvisning
Pump för inomhusfontän / Fontän Pump med lampa 9 V
I Istruzioni per l’uso
Pompa per fontana da interni / Pompa per gioco di acqua e luce 9 V
E Manual de instrucciones
Bomba para fuentes interiores / Bomba para juego de agua con luz 9 V
P Instruções de manejo
Bomba para fontes interiores / Bomba para jactos de água luminosos 9 V
DK Brugsanvisning
Springvandspumpe indendørs /terrasse / Springvandspumpe med lys 9 V
2
m
1,0
0,8
0,6
0,4
0,2
0
bar
0,10
0,08
0,06
0,04
0,02
012345678l/min
17
G
16
G
Attention
A GARDENA Indoor Fountain Pumps and Water Light Jet
Pumps have not been designed for constant use in the industrial sector. Corrosive, easily combustible, aggressive or explosive substances (e.g. petrol, petroleum, nitro thinner) as well as salt­water or food / drinking water must not be pumped.
A For Your Safety
The transformer should be operated via a residual current device with a residual current rating of 30 mA (DIN VDE 0100-702 and 0100-738). Please ask your electrician for his advice.
Mains power cables should not have a smaller cross-section than a PVC cable of the designation H03 VV. Extension cables must meet the requirements of DIN VDE 0620.
Before operating the pump, look to see if there is any damage of the pump. A damaged pump must not be used. In case of damage, please have the pump checked by our GARDENA Service Centre or by an authorised electrician.
Operating the Pump
Mains power cables
Visual check
GARDENA Indoor Fountain Pump
RRPP 330000,, 99 VV
Water Light Jet Pump
WWLLPP 330000 SS // WWLLPP 330000 BB
Welcome to GARDENA aquamotion ...
Please read these operating instructions carefully and observe the notes given. Use the instructions to familiarise yourself with the equipment, the operating controls, their correct use, and the notes on safety.
A For safety reasons, children under 16 as well as persons not
familiar with these operating instructions should not use this pump.
Keep these operating instructions in a safe place.
The Applications Range of your Pump
GARDENA Indoor Fountain Pumps and Water Light Jet Pumps have been designed for private use around your house. They are not designed for operating watering tools and systems. The pumps are designed for indoor use only.
Intended purpose
19
G
18
G
Operation
Before operation submerge the pump in the water.Take care that the pump is positioned in a way that the casing is completely immersed in water.
A The foam filter at the bottom must not be covered up at the
side!
Please note the maximum submersion depth (see “Technical Data”).
Put the plug of the pump into the socket of the mains plug and then the mains plug into a 230 V AC socket.
Caution! Pump will start immediately.
Adjust the volume according to your needs by turning the volume control. (Turning anti-clockwise increases the volume)
Installing the pump
Caution: Submersion depth
Switching on the pump
Volume regulator
Check line voltage. Data indicated on the type plate must match technical data of the mains supply.
The pump must not be operated when there are people in the water.
Do not use the power cable to carry the pump or to pull the plug. Protect the power cable from heat, oil and sharp edges.
Please unplug the pump after operation and before carrying out any maintenance works.
The temperature of the liquid used must not be below 4°C or above 35°C.
Sand and other abrasive substances in the liquid cause in­creased wear and reduce the output of the pump.
GARDENA pumps and plug connections have been designed exclusively for the use with 9 V low voltage.When connected to 230 V your life is at risk! Operate the pump only with the delivered transformer.
Do not expose the transformer to direct sunlight.
Check line voltage
Do not operate pump when people are in water
Do not use power cable to carry the pump
Disconnect plug
Temperature of the liquid used
Wear and reduced output
Caution! 9 V low voltage
Do not expose the transformer to sunlight
21
G
Dismantling of the Light Effect Jets
.
Disconnect plug transformer!
.
Remove the jet from the pump.
.
Pull off the top section of the jet of the light base.
.
Pull out the lamp.
.
Assemble the components in reverse order of the dismantling. While assembling take care that the cable of the lamp is correctly inserted into the side slot!
Only 12 V halogen lamps of max.5 watts may be used!
.
Disconnect plug transformer!
.
Take the jet out of the pump.
.
Unscrew the jet from the light base.
.
Pull off the bottom section of the light base.
.
Pull out the lamp.
.
Assemble the components in reverse order of the dismantling. While assembling take care that the cable of the lamp is correctly inserted into the side slot!
Only 12 V halogen lamps of max.5 watts may be used!
Water jet (WLP 300 S)
Light sphere (WLP 300 B)
Water jet (WLP 300 S)
Light sphere (WLP 300 B)
20
G
Avoid dry operation of the pump as dry running will produce undesirable heat and destroy the pump.
Only for WLP 300 S and WLP 300 B
Control/Setting of the Light Effect Jets
The light effects can be controlled with the volume control of the pump (see “Operation”).
.
Smaller diameters of light sphere: Turn the light effect control anti-clockwise upwards
.
Bigger diameters of light sphere: Turn the light effect control clockwise downwards.
Avoid dry operation
23
G
22
G
Dismantling
.
Pull out the plug transformer!
.
Remove the pump from the water.
.
Dismantle the casing fittings as follows:
1. Pull down and remove the filter.
2. Push away the pump casing from the motor casing at the pressure joint.
3. Pull the feed impeller out of the motor casing.
4. If necessary remove the volume control be moving it forwards.
.
Afterwards re-assemble the fittings reversing the order and direction in which they were dismantled.
Storage
A The pump should be stored out of the reach of children.
1. Take the pump out of the water and store away from frost before the first frost sets in.
2. Clean and check the pump carefully.
3. Store the pump in a container filled with water.
The mains plug must not be submerged.
22
Care Instructions
Take care that the pump is always completely submerged in water. A lack of water can cause the feed impeller to turn in the wrong direction.
Remedy :
Disconnect the plug transformer and fill the pump with water. Then connect the plug again.
The filter should be completely clean!
How to clean:
.
Pull out the plug transformer!
.
Clean the pump and the filter with a water jet.
.
Dismantle (and re-assemble afterwards) casing fittings and clean the fittings inside carefully with water as described in the paragraph “Dismantling”.
Inf
ormation: Do not use any hard objects or strong detergents!
If the feed impeller becomes blocked, the pump should be cleaned (see paragraph on “dismantling”).
Cleaning the filter
Blocked feed impeller
Where to store
25
G
24
G
Technical Data
Type RP 300, 9V WLP 300 S WLP 300 B Art. No. 7836 7839 7840 Rated power 14 W 14 W 14 W
Flow 300 l/ h 300 l/ h 300 l/ h Max. delivery head 0.7 m 0.7 m 0.7 m Max. submersion depth 0.4 m 0.4 m 0.4 m Power cable 1.5 m H03 VV 1.5 m H03 VV 1.5 m H03 VV Fitting 13 mm (1 /2 ”) 13 mm (1/ 2” ) 13 mm (1 /2 ”) Max. media temperature 35 °C 35 °C 35 °C Mains voltage 230 V 230 V 230 V Frequency 50 Hz 50 Hz 50 Hz
Noise level L
WA
1)
48 dB(A) 48 dB(A) 48 dB(A)
1) Measuring method according to EN 60335- 1
Information
If you have any problems with your pump, please contact our Service or return the defective unit together with a short descrip­tion of the problem – in case of guarantee, with a copy of the receipt – postage paid to one of the GARDENA Service Centres listed on the back of this leaflet.
We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories.
Complaints/ Repairs
Product liability
27
G
26
G
GARDENA guarantees this product for 3 years (from date of purchase). This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults. Under warranty we will either replace the unit or repair it free of charge if the following conditions apply:
.
The unit must have been handled properly and in keeping with the require-
ments of the operating in­structions. Neither the pur­chaser nor a non-authorised third party have attempted to repair the unit.
Parts subject to wear (e.g. feed impeller) are excluded from this guarantee.
This manufacturer’s guarantee does not affect the user’s exist­ing warranty claims against the dealer/ seller.
In the event of a fault, please send the defective unit together with the receipt and a descrip­tion of the fault, postage paid, to one of the GARDENA Service Centres on the back of this page.
GuaranteeEU Certificate of Conformity
The undersigned GARDENA Kress + Kastner GmbH · Hans-Lorenser-Str. 40 · D-89079 Ulm hereby certifies that, when leaving our factory, the units indicated below are in accordance with the
harmonised EU guidelines, EU standards of safety and product specific standards. This certificate becomes void if the units are modified without our approval.
Description of the units:
Indoor Fountain Pump / Water Light Jet Pump
Types:
RP 300, 9 V / WLP 300 S / WLP 300 B
Art. No. :
7836 / 7839 / 7840
EU directives:
Machinery Directive 98/37/ EC Electromagnetic Compatibility 89/336/EC Low Voltage Directive 73/ 23/ EC Directive 93/ 68/EC
Harmonised European standards:
EN 292- 1 EN 292- 2 EN 60335-1 EN 60335-2-41
Year of CE marking:
1999
Ulm, 01.06.1999
Thomas Heinl Technical Dept. Manager
115114
Greece
Agrokip G. Psomadopoulos & Co. 20, Lykourgou str. Kallithea - Athens
Hungary
GARDENA Magyarország Kft. Késmárk utca 22 1158 Budapest
Iceland
Heimilistaeki hf Saetun 8 P.O. Box 5340 125 Reykjavik
Republic of Ireland
Michael McLoughlin & Sons Hardware Limited Long Mile Road Dublin 12
Italy
GARDENA Italia S.r.l. Via Donizetti 22 20020 Lainate (Mi)
Japan
KAKUDAI Mfg. Co. Ltd. 1-4 -4, Itachibori Nishi-ku Osaka 550
Luxembourg
Magasins Jules Neuberg Grand Rue 30 Case Postale No.12 Luxembourg 2010
Netherlands
MARKT (Holland) BV Postbus 219 1380 AE Weesp
Neth. Antilles
Jonka Enterprises N.V. Sta. Rosa Weg 196 P.O. Box 8200 Curaçao
New Zealand
NYLEX New Zealand Limited Private Bag 94001 South Auckland Mail Centre 10 Offenhauser Drive East Tamaki, Manukau
Norway
GARDENA Norge A/ S Postboks 214 2013 Skjetten
Poland
GARDENA Polska Sp. z o.o. Szymanów 9 d 05- 532 Baniocha
Portugal
MARKT (Portugal), Lda. Recta da Granja do Marquês Edif. GARDENA Algueirão 2725-596 Mem Martins
Russia / Россия
АО АМИДА ТТЦ ул. Моcфилмовcкая 66 117330 Моcква
Singapore
Variware Holland Road Shopping Centre 227-A 1st Fl., Unit 29 Holland Avenue Singapore 1027
Slowenia / Croatia
Silk d.o.o. Trgovina Brodišče 15 1236 Trzin
Deutschland
GARDENA Kress + Kastner GmbH GARDENA Service Hans-Lorenser-Straße 40 D-89079 Ulm Produktfragen: (07 31) 490- 123 Reparaturen: (07 31) 490- 290
Argentina
Argensem S.A. Venezuela 1075 (1618) El Talar - Buenos Aires
Australia
NYLEX Corporation Ltd. 25- 29 Nepean Highway P.O. Box 68 Mentone, Victoria 3194
Austria
GARDENA Österreich Ges. m.b.H. Stettnerweg 11-15 2100 Korneuburg
Belgium
MARKT (Belgium) NV/SA Sterrebeekstraat 163 1930 Zaventem
Brazil
M. Cassab Av.das Nações Unidas, 20.882 Santo Amaro, CEP 04795-000 São Paulo - S.P.
Bulgaria / България ДЕНЕКС ООД бул. „Черни връх“ 43 София 1407
Canada
GARDENA Canada Ltd. 100, Summerlea Road Brampton, Ontario Canada L6T 4X3
Chile
Antonio Martinic Y CIA. LTDA. Gilberto Fuenzalida 185 Loc. Las Condes Santiago de Chile
Costa Rica
Compania Exim Euroiberoamericana S.A. 350 Sur del Automercado Los Yoses San Pedro
Cyprus
FARMOKIPIKI LTD P.O. Box 7098 74, Digeni Akrita Ave. 1641 Nicosia
Czech Republic
GARDENA spol. s.r.o. Ripská 20 62700 Brno
Denmark
GARDENA Danmark A/ S Naverland 8 2600 Glostrup
Finland
Habitec Oy Martinkyläntie 52 01720 Vantaa
France
GARDENA France Service Après-Vente BP 50080 95948 ROISSY CDG Cedex
Great Britain
GARDENA UK Ltd. 27- 28 Brenkley Way Blezard Business Park Seaton Burn Newcastle upon Tyne NE13 6DS
South Africa
GARDENA South Africa (Pty.) Ltd. P.O. Box 11534 Vorna Valley 1686
Spain
ANMI Andreu y Miriam S.A. Calle Pere IV, 111 08018 Barcelona
Sweden
GARDENA Svenska AB Box 9003 20039 Malmö
Switzerland
GARDENA Kress + Kastner AG Bitziberg 1 8184 Bachenbülach
Ukraine / Украина
АОЗТ АЛЬЦЕСТ ул. Гайдара 50 г. Киев 01033
Turkey
Dost Dis Ticaret Mümessillik A.Þ. Yali Mah. Turgut Pasa Cad. No: 7 1/2 Kartal - Ýstanbul
USA
GARDENA 3085 Shawnee Drive Winchester, VA 22604
7836- 20.960.05 /0001 GARDENA Kress + Kastner GmbH Postfach 27 47, D-89070 Ulm http: //www.gardena.de
T3055116181E/Id .22245/07H
Loading...