Gardena FP 750 E, FP 1000 E, FP 1800 E, FP 1400 E, FP 2500 E Operating Instructions Manual

...
FP 750 E Art. 7650 FP 1000 E Art. 7651 FP 1400 E Art. 7652 FP 1800 E Art. 7653 FP 2500 E Art. 7654
FP 4000 E Art. 7655 FP 5000 E Art. 7656 FP 7500 E Art. 7657
GARDENA
®
D Betriebsanleitung
Wasserspielpumpen-Set
Fountain Pump Set
F Mode d’emploi
Pompe pour jets d’eau
NL Instructies voor gebruik
Waterspelpomp-set
S Bruksanvisning
Fontän Pump Set
I Istruzioni per l’uso
Pompa per giochi d’acqua
E Manual de instrucciones
Bomba para juegos de agua
P Instruções de manejo
Bomba para fontes
DK Brugsanvisning
Springvandspumpesæt
D
GBFNLS
I
E
P
DK
GARDENA Fountain Pump Set
FP 750 E / FP 1000 E / FP 1400 E / FP 1800 E / FP 2500 E FP 4000 E / FP 5000 E / FP 7500 E
Welcome to the Garden of GARDENA ...
Translation of the original instructions from German. Please read these operating instructions carefully and observe the notes given. Use the instructions to familiarise yourself with the equipment, the operating controls, their correct use, and the notes on safety.
For safety reasons, children under 16 as well as persons not familiar with these operating instructions must not use this Fountain Pump Set.
v Keep these operating instructions in a safe place.
1. Where to use Your GARDENA Fountain Pump Set
. . . . . . . . . . . 9
2. For Your Safety
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3. Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6. Trouble-shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7. Storing your Fountain Pump Set
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
8. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
9. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
10. Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1. Where to use Your GARDENA Fountain Pump Set
GARDENA Fountain Pumps have been designed for private use. They are not designed for operating watering tools and systems. The pumps may be used indoors as well as outdoors.
GARDENA Fountain Pumps have not been designed for con­stant use in the industrial sector. Corrosive, easily combustible, aggressive or explosive substances (e.g. petrol, petroleum, nitro thinner) as well as salt-water or food / drinking water must not be pumped.
Intended Use
Please note
2. For Your Safety
Electrical Safety:
The pump should be operated via a residual current device with a residual current rating of 30 mA (DIN VDE 0100-702 and 0100-738). The pump must be placed on solid, even ground.
v Please ask your electrician for his advice.
Always disconnect the pump from the mains before undertaking any work on it.
Mains power cables should not have a smaller cross-section than a rubber sheathed cable of the designation H05 RN-F 3G0,75 (FP 4000 E, FP 5000 E, FP 7500 E0: H05 RN-F 3G1,0).
Extension cables must meet the requirements of DIN VDE 0620.
Check line voltage. Data indicated on the type plate must match technical data of the mains supply.
Contents
9
GB
10
GB
The pump must not be operated when there are people in the water. Swimming pools and garden ponds should be designed according to international and national design regulations.
v Please consult a professional electrician.
For Austria:
Pumps for use on swimming pools and on ponds may only be operated via an isolating transformer.
v Please consult a professional electrician.
For Switzerland:
In Switzerland mobile appliances which are used outdoors, must be connected via a resi­dual-current device.
Note:
Do not allow the pump to run without water because dry-running leads to an undesira­ble build up of heat.
Before operating the pump, look to see if there is any damage to the pump (esp. regarding power cable and plug). The connection cable of the pump cannot be replaced. If the cable is damaged the pump must be scrapped. Ensure that the power cable cannot be crushed if it has not been laid in conduit in the earth or in gravel.
Do not use the power cable to carry the pump or to pull the plug out of the socket. Protect the power cable from heat, oil and sharp edges.
The temperature of the liquid used must not be below 4 °C or above 35 °C.
Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump.
Please observe the local noise prevention regulations.
All pumps
(a cascade
art. 7650
(b Waterbell
-
7654
(c jets of
water
art. 7655
-
7657
(d foaming -
spring
3. Assembly
To provide a firmer mounting, the filter housing can be attached to a solid base (e.g. paving stone).
1. Screw nozzle pipe
1
on to the pump with the ball and socket
joint.
2. Screw the water feature insert you require (a / (b / (c / (d on the nozzle pipe 1.
2
Holder for GARDENA underwater light art 7951
The additional filter can be fitted on the filter housing to extend the maintenance interval and to give the water feature a longer life.
1. Remove the cap
3
from the pump.
2. Fit both filter shells 4on the filter housing 5and clip into place.
3. Press sealing cover
3
on to the additional filter 4.
You can install additional filters
z
4a
to increase the filter surface.
Additional filters are available from GARDENA Service.
Fit the pump:
VARIANT 1 : Mount the additional filter on the pump:
2
1
5
3
4
z
4a
11
GB
The additional filter can be installed as a pond edge controller for adjusting water features and cleaning the filter housing from the edge of the pond. Water is only drawn in via the additional filter. You can connect the following hoses to the hose connection:
.
3/4” and 1” for FP 750 E / FP 1000 E / FP 1400 E / FP 1800 E / FP 2500 E
.
11/4” and 1 1/2” for FP 4000 E / FP 5000 E / FP 7500 E
For best results use a hose with the largest possible diameter.
1. Remove the cap
3
from the pump.
2. Press in snap fastenings
6
and
open up the filter housing 5.
3. Push the hose connection
7
on to the pump.
4. Close filter housing 5.
5. Insert hose connection 8in to one filter shell 4and snap into the second filter shell
4
.
6. Press sealing cover 3on to the pond edge control 4.
7. Connect water feature pump and pond edge control to a hose.
4. Initial Operation
1. Place water feature pump on a firm base in such a way that the filter housing 5is completely covered by water.
2. Pull telescopic pipe 9out to the desired length.
3. Netzstecker in eine Wechselstromsteckdose einstecken.
Warning: Pump will start immediately.
4. Set the quantity of water required for the water feature using the regulator
0
.
5. Water bell: Screw insert into the water feature until the water feature has produced the shape required.
TIP: Install the pond edge controller on a bed of gravel to improve the water intake. The regulating valve
0
must be fully
open when using the pond edge controller.
1. Fill hose with water to remove any cushions of air in the hose.
2. Secure the pond edge controller at the edge of the pond (using rocks, for example).
The pond edge control must be completely covered with water.
3. Set the quantity of water required for the water feature with the regulator
A
.
Switch on water feature pump:
Start pond edge control:
VARIANT 2 : Mount the pond edge controller:
0
A
9
5
0
9
5
4
3
8
7
7