In Austria power cables should correspond to ÖVE-EM 42, T 2 (2000)/ 1979 § 22 according to § 2022.1. According to this standard pumps used in swimming pools and ponds should only be operated via an isolating transformer.
v Please contact your electrician.
In Switzerland mobile appliances which are used outdoors, must be connected via a residual-current device.
Before operating the pump, look to see if there is any damage of the pump (esp. regarding power cable and plug). A damaged pump must not be used. In case of damage, please have the pump checked by our GARDENA Service Centre or by an authorised electrician.
Data indicated on the type plate must match technical data of the mains supply.
The pump must not be operated when there are people in the water.
Swimming pools and garden ponds should be designed according to international and national design regulations.
v Please consult a professional electrician.
Do not use the power cable to carry the pump or to pull the plug out of the socket. Protect the power cable from heat, oil and sharp edges.
Always unplug the equipment when dismantling the set, when it is not in use and before maintenance.
v Always disconnect the pump from the mains before under-
taking any work on it.
v Please follow the safety and assembly instructions in these
operating instructions.
The temperature of the liquid used must not be below 4°C or above 35°C.
Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump.
v Place the filter in a stable position alongside or in your
garden pond.
If the filter is placed alongside the pond, it must be set up above the surface of the pond.
For Austria
For Switzerland
Visual check
Check line voltage
Do not operate pump when there are people in the water
Swimming pools and garden ponds
Do not use power cable to carry the pump
Disconnect plug
Temperature of the liquid used
Wear and reduced output
Positioning the filter
Intended purpose
Please note
GARDENA Filter Set 5000
Welcome to GARDENA aquamotion...
Please read these operating instructions carefully and follow the instructions. Use the instructions to familiarise yourself with the Filter Set, using it correctly and the safety information.
For safety reasons, children and young people under 16 years of age and people who are not acquainted with these operating instructions should not use this Filter Set.
v Please keep these operating instructions in a safe place.
1. The Applications Range of Your GARDENA Filter Set
. . . . . . . 10
2. For Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3. Mode of Operation of the Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4. Putting into Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6. Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
7. Putting out of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
8. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
9. Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1. The Applications Range of Your GARDENA Filter Set
The GARDENA filter set is intended for domestic use in your garden where it should only be used alongside or in your garden pond for cleaning garden ponds up to 5 m
3
in size with and
without fish.
The GARDENA Filter Set is not suitable for industrial use or in combination with chemicals, food, easily combustible and explo­sive substances. It is not intended for operating watering equip­ment and systems.
Contents
2. For Your Safety
The pump should be operated via a residual current device with a residual current rating of 30 mA (DIN VDE 0100-702 and 0100-738).
v Please ask your electrician for his advice. The pump must be placed on solid, even ground.
Mains power cables should not have a smaller cross-section than a rubber sheathed cable of the designation H05 RNF. Extension cables must meet the requirements of DIN VDE
0620.
Operating the pump
Mains power cables