Intended use
Please note
Contents
GARDENA UVC Underwater Filter with Fountain Pump Set FFP 5000 UVC
Translation of the original instructions from German. Please read these operating instructions carefully and observe the notes given. Use these operating instructions to familiarise yourself with the UVC Underwater Filter with Fountain Pump Set, its proper use and the safety instructions.
For safety reasons, children under 16 as well as persons not familiar with these operating instructions must not use this UVC Underwater Filter with Fountain Pump Set.
v Keep these operating instructions in a safe place.
1. Where to useYour GARDENA UVC Underwater Filter with Fountain Pump Set
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2. Safety Instructions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3. Assembly
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4. Initial Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5. Putting into Storage
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6. Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7. Troubleshooting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
8. Accessories
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9. Technical Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
10. Service / Warranty
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1. Where to use your GARDENA UVC Underwater Filter with Fountain Pump Set
The GARDENA UVC Underwater Filter is for private use for cleaning outdoor garden ponds up to 5000 l with and without fish stocks. It is not designed for operating watering equipment or irrigation systems. The pond can be aerated with the UVC Underwater Filter together with the Pond Aerator Art. 7942 /7943.
The GARDENA UVC Underwater Filter is not suitable for continuous operation in industrial applications. Corrosive, easily combustible, aggressive or explosive substances (e.g. petrol, petroleum, nitro thinner) as well as saltwater or food and drinking water must not be pumped.
2. Safety Instructions
V Comply with the safety instructions on the UVC Underwater Filter.
WARNING! V Read the operating
instructions before using the equipment for the first time!
DANGER ! Protect eyes from flash. This radiation is harmful
to eyes and skin.
12
GB
Never operate the UVC Underwater Filter
when the housing has been removed.
Electrical Safety:
The UVC Underwater Filter must be operated via a residual-current device (FI-switch) with a nominal fault current 30 mA (DIN VDE 0100-702 and 0100-738). The UVC Underwater Filter must be placed on solid, even ground.
v Please ask your electrician for his advice.
Always disconnect the UVC Underwater Filter from the mains before undertaking any work on it.
Power cables must not be of lower quality than the H05 RNF rubber hose lines. Extension cables must meet the requirements of DIN VDE 0620.
The information on the model plate of the UVC Underwater Filter must match the power supply.
The connection cable of the Pump and the UVC Underwater Filter cannot be replaced. If there is any damage to the mains connection lead the corresponding unit must be disposed of.
Do not use extension leads, connection leads or adapters without a protective contact.
Never carry the UVC Underwater Filter by the cable. Do not pull on the cable to unplug the plug from the socket.
Please protect the cable from heat, oil and sharp edges. Make sure that connection points remain dry.
Please unplug the pump and the UVC Under­water Filter after operation and before carrying out any maintenance works.
The UVC Underwater Filter must not be operated when there are people in the water.
Swimming pools and garden ponds should be designed according to international and national design regulations.
v Please consult a professional electrician.
For Austria
Units for use in swimming pools and in ponds must only be operated via an isolating trans­former.
v Please consult a professional electrician.
For Switzerland
In Switzerland mobile appliances which are used outdoors, must be connected via a residual-current device.
Note:
v Inspect the equipment before use to en-
sure that the Pump and the UVC Under­water Filter, especially the power cable and plug, are undamaged.
Do not use a damaged UVC Underwater Filter.
Do not use the light if the connection lead, glass tube or the housing of the UVC unit appear to be defective.
If the Pump or UVC Underwater Filter are damaged, please have them checked by our GARDENA Service Centre or an authorised electrician.
The temperature of the liquid used must not be below 4 °C or above 35 °C.
Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump.
Do not allow the pump to run without water because dry-running leads to an undesirable build up of heat.
UVC unit safety switch:
If the UVC light overheats, it is switched off by the built-in thermal protection switch. The UVC light switches itself on again auto­matically when it has cooled down sufficiently.
Due to a built-in safety switch, the lamp only lights up when the UVC unit has been fully installed.
v Never operate the UVC unit without water
throughput.
13
GB
B
Installing the set as a stream pump :
3. Assembly
v To assemble the UVC lamp see 7. Troubleshooting
“Replacing the UVC bulb”
.
The stepped nipple (½
"/¾"
)6can be used for connection, for example, to a gargoyle. If the side outlet is not needed the 6sealing cap 8can be screwed in instead of the step nipple.
1. Screw the T-joint 7onto the connection 1.
2. Screw the stepped nipple
6
onto the side outlet of the
T-piece 7.
3. Screw the ball joint
2
onto the T-piece 7.
4. Push the nozzle tube
3
onto the telescopic handle bup to
the sleeve a.
5. Snap the nozzle tube
3
into the ball joint 2.
6. Screw required fountain insert
4
a) / b) / c) / d) fully into the
nozzle tube
3
.
a) Cascade b) Water Bell c) Fleur-de-Lis d) Water Jets
The stepped nipple (½"/¾")6can be used for connection, for example, to a stream or source stone.
1. Screw the T-joint
7
onto the connection 1.
2. Screw the stepped nipple
6
onto the side outlet of the
T-piece
7
.
3. Screw the cap
8
onto the T-piece 7.
The GARDENA Pond Aerator Art. 7942 / 7943 can be con­nected to increase the oxygen content. The aragonite and the hose are supplied with the pond aerator.
1. Remove the filter housing (see 6. Maintenance).
2. Connect the aragonite
9
with a piece of hose to the air con-
nection piece 0.
3. Put the aragonite
9
between the filter stone bags ensuring
that the hose is not kinked.
4. Connect the pond aerator hose
A
to the air connection piece
0
from the outside.
Assembling the UVC bulb:
A
Installing the set as a fountain pump:
Connecting the pond aerator (available as an option):
7
1
8
6
3
2
1
4
a b
7
6
9
0
A
9
A
Loading...
+ 9 hidden pages