Gardena FFP 3000, 7887, FFP 5000, 7888 Operating Instructions Manual

GARDENA
®
FFP 3000 Art. 7887 FFP 5000 Art. 7888
D Gebrauchsanweisung
Teichfilter mit Wasserspielpumpen- Set
GB Operating Instructions
F Mode d’emploi
Filtre de bassin avec kit pompe pour jets d’eau
NL Gebruiksaanwijzing
Vijverfilter met waterspelpomp-set
S Bruksanvisning
Dammfilter med pumpset för fontän
I Istruzioni per l’uso
Filtro per laghetti con set di pompe per giochi d’acqua
E Manual de instrucciones
Filtro para estanque con juego de bombas para efectos de agua
P Instruções de manejo
Conjunto de filtro para lagos com bomba de jogos de água
DK Brugsanvisning
Damfilter med springvandspumpesæt
D
GBFNLS
I
E
P
DK
8
GB
GARDENA Pond Filter and Fountain Pump Set FFP 3000 / FFP 5000
Welcome to the Garden of GARDENA ...
Please read these operating instructions carefully and observe the notes given. Use these operating instructions to familiarise yourself with the Pond Filter and Fountain Pump Set, its proper use and the safety instructions.
For safety reasons, children under 16 as well as persons not familiar with these operating instructions must not use this Pond Filter and Fountain Pump Set.
v Keep these operating instructions in a safe place.
1. Where to use Your Pond Filter and Fountain Pump Set
. . . . . . . 8
2. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3. Assembly
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6. Trouble-shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
7. Storing your Fountain Pump Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
8. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
9. Technical Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
10. Service / Warranty
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1. Where to use your GARDENA Pond Filter and Fountain Pump Set
The GARDENA Pond Filter and Fountain Pump Set is for private use for cleaning outdoor garden ponds with and without fish stocks. It is not designed for operating watering equipment or irrigation systems.
The GARDENA Pond Filter and Fountain Pump Set is not suitable for continuous operation in industrial applications. Corrosive, easily combustible, aggressive or explosive sub­stances (e.g. petrol, petroleum, nitro thinner) as well as salt­water or food and drinking water must not be pumped.
Intended Use
Please note
Contents
2. Safety instructions
Electrical Safety:
The pump should be operated via a residual current device with a residual current rating of 30 mA (DIN VDE 0100-702 and 0100-738). The pump must be placed on solid, even ground.
v Please ask your electrician for his advice.
Always disconnect the pump from the mains before undertaking any work on it.
Mains power cables should not have a smaller cross-section than a rubber sheathed cable of the designation H05 RN-3G x 0,75. Extension cables must meet the requirements of DIN VDE 0620.
Data indicated on the type plate must match technical data of the mains supply.
Please unplug the pump after operation and before carrying out any maintenance works.
9
GB
3. Assembly
A Fit the Fountain to the Pond Filter:
1. Click the nozzle tube 1into the ball joint 2.
2. Screw the nozzle tube
1
on the threaded spigot on the pump.
3. Screw the desired fountain insert
3
a) / b) / c) / d) into the
nozzle tube 1.
a) Cascade b) Water Bell b) Fleur-de-Lis d) Water Jets
Side outlet
4
: Additional consumers (e.g. gargoyles) can be connected to the side outlet4[9 mm / 13 mm (1/ 2 )]. The quantity of water can be adjusted via the regulator 5.
B Fit the stepped nipple (
1/2
- 3/4) to the Pond Filter :
The stepped nipple 6can be used to supply features such as a stream or a source stone.
1. Screw the stepped nipple
6
on the threaded spigot on the pump, having first checked that the O-Ring zis in place within the stepped nipple.
2. Push the hose on to the stepped nipple
6
.
Note: If a 3/4hose is used, the front part of the stepped nipple can be cut off using a saw.
Installing the Pond Filter:
The pump must not be operated when there are people in the water. Swimming pools and garden ponds should be designed according to international and national design regula­tions.
v Please consult a professional electrician.
For Austria:
Pumps for use on swimming pools and on ponds may only be operated via an isolating transformer.
v Please consult a professional electrician.
For Switzerland:
In Switzerland mobile appliances which are used outdoors, must be connected via a residual-current device.
Note:
Do not allow the pump to run without water because dry-running leads to an
undesirable build up of heat and will destroy the pump.
Before operating the pump, look to see if there is any damage to the pump (esp. regarding power cable and plug). The connection cable of the pump cannot be replaced. If the cable is damaged the pump must be scrapped.
Do not use the power cable to carry the pump or to pull the plug out of the socket. Protect the power cable from heat, oil and sharp edges.
The temperature of the liquid used must not be below 4 °C or above 35 °C.
Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump.
Please observe the local noise prevention regulations.
O