GB
Translation of the original operating instructions from German. Please read these operating instructions carefully and observe the notes given. Use these operating instructions to familiarise yourself with the Pressure Tank Unit, its proper use and the safety instructions.
For safety reasons, children and young people under 16 years of age as well as people who are not familiar with these operating instructions should not use this Pressure Tank Unit.
Please keep these operating instructions in a safe place.
Contents: 1. Where to use your GARDENA Pressure Tank Unit. . . . . . . . 11
2. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3. Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
8. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9. Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
10. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1. Where to use your GARDENA Pressure Tank Unit
Correct use: The GARDENA Pressure Tank Unit is intended for private use in
the house and garden; it is not intended for operation of watering equipment and accessories in public gardens.
Open consumers (e.g. taps) can cause fluctuations in pressure at certain rates of flow around opening and closing.
Liquids pumped: The GARDENA Pressure Tank Unit can be used to deliver rain-
water, tap water and chlorinated swimming pool water.
Please note:
The GARDENA Pressure Tank Unit is not suitable for continuous operation (e.g. industrial use, continuous circulation operations). Corrosive, easily combustible, aggressive or explosive liquids (such as gasoline, petroleum or nitro thinner), saltwater and food must not be pumped. The temperature of the liquid must not exceed 35 °C.
GARDENA Pressure Tank Unit 3000/4, 4000/5, 5000/5, 5000/5 Inox
Welcome to the Garden of GARDENA ...
12
GB
Electrical safety:
DANGER ! Electric shock ! Risk of injury due to electric
shock !
Always unplug your Garden Pressure
Tank Unit before
filling, after operation, when troubleshooting and before carrying out any maintenance work.
Caution: Pursuant to DIN VDE 0100-702 use of the pump near to swimming pools and garden ponds and other similar places is only permissible if the pump is operated via a residual-current device (FI switch) with a residual current rating of 30 mA.
The pump must be located on solid, even ground, protected from flooding. Take care that the pump cannot fall into water.
As an additional safety device an authorised safety switch can be used.
Please ask your electrician for his advice. Data indicated on the type plate must match
the technical data of the mains supply. Pursuant to DIN VDE 0620 the power cable as
well as any extension cable must not have a smaller diameter than rubber sheathed cables described with letter symbols H07 RNF.
Protect the power cable from heat, oil and sharp edges.
Do not use the power cable for carrying the pump or for unplugging.
In Austria
In Austria the electrical connection must satisfy the ÖVE-EM 42, T2 (2000)/1979 § 22 to §
2022.1. This requires that pumps used for swimming pools and garden ponds may only be powered through an isolating transformer.
Please ask your electrician for his advice.
In Switzerland
In Switzerland portable devices that are used outdoors must be connected through an earth leakage circuit breaker. Mobile appliances that are used outdoors must be connected via a residual-current device.
2. Safety instructions
General Information:
Risk of injury due to hot water !
If the pressure switch is defective and the pressure tank unit runs for an extended period (> 5 min) when the pressure side outlets are closed, the water in the pressure tank unit can become heated so that hot water can emerge from the outlet and cause injuries.
Pump may only run for max. 5 min with
the discharge side closed.
If the water supply on the intake side of the pump fails, the water in the pump can heat up so that if water emerges, injuries could be caused by the hot water.
Disconnect pump from the mains, allow
water to cool down and ensure the water supply is functioning correctly before starting the pump again.
Before operating the pressure tank unit, first
make a visual check to ensure there is no damage to the
pressure tank unit (especially
regarding power cable and plug).
A damaged pressure tank unit must not be used.
In case of damage, please have the pressure tank unit checked by our GARDENA Service Centre or by an authorised electrician.
Protect the pump from rain. Do not use the pressure tank unit in a wet or moist area.
In order to avoid dry-running of the pressure tank unit, take care that the end of the suction hose is always submerged into the liquid.
The pressure tank unit must not be run dry nor with the stopcock in the suction pipework clo­sed.
Before each operation, fill the pressure tank
unit to overflowing with approx. 2 to 3 l of the liquid to be pumped!
Sand and other abrasive substances in the liquid cause increased wear and reduce the pump’s output.
When using the pump for domestic water supply, please adhere to the local water and sewerage regulations. In addition observe the regulations of DIN 1988.
If necessary contact your local water
authority.
13
GB
3. Installation
Installing the The installation position must be firm and dry, and permit a secure Pressure Tank Unit: mounting for the pressure tank unit.
Install the pump at a safe distance (min. 2 m) from the pump-
ing medium.
The pump must be installed in a location with low air humidity and sufficient ventilation in the area of the ventilation slots. It must be at a distance of at least 5 cm from the walls. No dirt contamination (e.g. sand or earth) may be sucked in through the ventilation slots.
Fixed installation of the The mounting board (e. g. a wooden board) prevents the Pressure Tank Unit: pressure tank unit slipping.
Screw the pressure tank unit to the mounting plate with all four feet (The use of cap screws is recommended).
Install the pressure tank unit so that there is room to place a suitably sized drainage tray under the drain screw . To allow the unit or system to be drained.
If possible install the unit higher than the surface of the water to be pumped. If this is not possible, install a vacuum-resistant shut-off device between the unit and the suction hose, for example for cleaning the integrated filter.
If the pressure tank unit is being permanently installed indoors for domestic water supply, the Pressure Tank Unit should not be connected to the domestic water pipework with rigid pipes but with flexible hoses, to reduce noise and to avoid damage to the pressure switch due to vibration.
If the system is being installed permanently, please fit suitable shut-off devices on both the intake and delivery sides. This is important e.g. for maintenance and cleaning work or if the system is being shut down.
The connection pieces on the intake and delivery sides must only be tightened by hand.
Connect the hose to the Do not use any water hose snap connection system components suction side: on the intake side. A vacuum-tight suction hose must be used e.g.
• GARDENA Suction Hose Art. no. 1411
• GARDENA borehole Suction Hose Art. no.1729. To reduce the pump repriming time, we recommend:
• using a suction hose with backflow preventer, which prevents the suction hose emptying automatically when the Pressure Tank Unit is switched off.
• If the suction heights are high, use a suction hose with a small diameter.
1. Connect vacuum-tight suction hose via a connection piece (e.g. Art. no. 1723/1724) to the connection on the intake side and screw in place so that it is airtight.
2. For suction heights exceeding 4 m also secure the suction hose  (e.g. by fastening it to a wooden post).
This relieves the pump of the weight of the suction hose.
If very fine dirt is present, we recommend the use of a GARDENA pump preliminary filter art. 1730/1731 in addition to the integrated
filter.