Gardena Classic 3500/4E, Classic 4000/5E Operating Instructions Manual

Classic 3500/4E Art. 1757 Comfort 4000/5E Art. 1758
LV LT EST AL BG TR RO UA
SRB
BIH
HR SLO
RUS
D Betriebsanleitung
Hauswasserautomat
GB Operating Instructions
Electronic Pressure Pump
F Mode d’emploi
Station de pompage
NL Gebruiksaanwijzing
Elektronische hydrofoorpomp
S Bruksanvisning
Pumpautomat
DK Brugsanvisning
Husvandværk
FI Käyttöohje
Painevesipumppu
N Bruksanvisning
Trykkpumpe
I Istruzioni per l’uso
Pompa ad intervento automatico
E Instrucciones de empleo
Estación de bombeo
P Manual de instruções
Bomba de pressão
PL Instrukcja obsługi
Hydrofor
H Használati utasítás
Háztartási automata szivattyú
CZ Návod k obsluze
Domácí vodní automat
SK Návod na obsluhu
Domáci vodný automat
GR Οδηγίες χρήσης
Συσκευή παραγωγής νερού
οικιακής χρήσης
RUS Инструкция по эксплуатации
Автоматический напорный
насос
SLO Navodilo za uporabo
Hišna vodni avtomat
HR Upute za uporabu
Kućni automat za vodu
SRB Uputstvo za rad BIH Hidropak
UA Інструкція з експлуатації
Помпа напірна автоматична
RO Instrucţiuni de utilizare
Hidroforul Electronic
TR Kullanma Kılavuzu
Konut suyu hidroforları
BG Инструкция за експлоатация
Помпа с електронен пресостат
за високо налягане
AL Manual përdorimi
Automati i ujit i shtëpisë
EST Kasutusjuhend
Pump-veeautomaat
LT Eksploatavimo instrukcija
Buitinis automatinis slėgimo
siurblys
LV Lietošanas instrukcija
Elektroniskais ūdens sūknis
GARDENA Electronic Pressure Pump Classic 3500/4E / Comfort 4000/5E
Translation of the original German operating instructions.
Please read the operating instructions carefully and observe the notes given. Use these operating instructions to familiarise yourself with the product, the proper use and the safety instructions.
Never operate the product when you are tired, ill or under the influence of alcohol, drugs or medicine.
This product may be used under supervision, or if instruction regarding the safe use of the product has been provided and the resulting dangers have been understood, by children aged 8 and above, as well as by persons with physical, sensory or mental disabilities or a lack of experience and knowledge. Children must not be allowed to play with the product. Cleaning and user maintenance must not be performed by children without supervision. The use of this product by young people under the age of 16 is not recommended.
v Keep these operating instructions in a safe place.
Contents: 1. Area of application of your GARDENA Electronic Pressure
Pump ............................................14
2. Safety Instructions .................................15
3. Function .........................................16
4. Initial Operation ....................................17
5. Operation ........................................18
6. Storage ..........................................19
7. Maintenance ......................................19
8. Troubleshooting ...................................20
9. Available accessories ...............................23
10. Technical Data ....................................24
11. Service / Warranty ..................................24
1. Area of application of your GARDENA Electronic Pressure Pump
Correct use: GARDENA Electronic Pressure Pumps have been designed for
private use around the house and garden. Electronic Pressure
Pumps are predominantly used for operating watering systems and systems in private gardens.
When using the pump for pressure intensification, the maximum permissible internal pressure of 6 bar (on the delivery side) must not be exceeded. The delivery pressure to be increased and the pump pressure have to be added together.
• Example: pressure at the tap = 2.0 bar, maximum pressure of the Electronic Pressure Pump 3500/4E = 3.5 bar, total pressure = 5.5 bar.
14
GB
2. Safety Instructions
Electrical safety
DANGER! Electric shock!
Risk of injury due to electric shock!
v Always unplug your pump before filling,
after operation, before troubleshooting and before carrying out any maintenance work.
The pump must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
The pump must be located on solid, even ground, protected from flooding. Take care that the pump cannot fall into water.
As an additional safety device an approved safety switch can be used.
v Please ask your electrician for his advice. When connecting the pump to the water supply
system, the country-specific sanitary regula­tions must be observed to prevent water not of drinking water quality being drawn back in.
Extension cables
Data indicated on the type plate must match the technical data of the mains supply.
Following DIN VDE 0620 the power cable as well as any extension cable must not have a smaller diameter than rubber sheathed cables described with letter symbols H07 RNF.
v If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Protect the power cable from heat, oil and sharp edges.
v Do not use the power cable for carrying the
pump or for unplugging.
In Austria
In Austria the electrical connection must satisfy the ÖVE-EM 42, T2 (2000)/1979 § 22 to § 2022.1. This requires that pumps used for swimming pools and garden ponds may only be powered through an isolating trans former.
v Please ask your electrician for his advice.
In Switzerland
In Switzerland portable devices that are used outdoors must be connected through a residual­current device.
General Information
Risk of injury due to hot water!
If the electronic control is defective or if the water supply on the intake side of the pump fails, any water remaining in the pump may heat up, generating a risk of injuries caused by hot water on leakage.
v Disconnect the pump from the mains
via the main circuit breaker, let the water cool (approx. 10 – 15 min.) and secure the water supply on the intake side before putting into operation again.
Visual check
v Before operating the pump, first make
a visual check to ensure there is no damage to the pump (especially regarding power cable and plug).
Liquids pumped: The GARDENA Electronic Pressure Pump can be used for
pumping rainwater, tap water and chlorinated swimming pool water.
Please note:
The GARDENA Electronic Pressure Pump is not suitable for continuous operation (e. g. industrial applications, contin­uous circulating operation). Corrosive, easily combustible, aggressive or explosive liquids (such as gasoline, petroleum or nitrothinner), saltwater and food intended for consump­tion must not be pumped. The temperature of the liquid must not exceed 35 °C. Before the beginning of the frost period, the Electronic Pressure Pump must be drained and placed in frost-proof storage (see 6. Storage).
15
GB
A damaged pump must not be used. v In case of damage, please have the pump
checked by our GARDENA Service Centre or by an authorised electrician.
Safety in operation
Protect the pump from rain. Do not use the pump in a wet or moist area.
In order to avoid dry-running of the pump, take care that the end of the suction hose is always submerged into the water.
v Before each operation, fill the pump to
overflowing with approx. 2 to 3 l of water to be pumped!
Very fine sand can pass through the inte­gratedfilter (mesh size 0.45 mm) and cause accelerated wear in the hydraulic parts.
v For sandy water, you should additionally use
the GARDENA pump pre-filter, art. no. 1730 (mesh size 0.1 mm).
Please ensure that no unauthorised persons or children are within reach of the pump and the pumped medium without supervision.
When using the pump for domestic water supply, please adhere to the local water and sewerage regulations. In addition observe the regulations of DIN 1988.
v If necessary, contact your local water
authority.
Warning! This pump produces an electro­magnetical field during operation. This field may under some circumstances interfere with active or passive medical implants. To reduce the risk of serious or fatal injury, we recommend persons with medical implants to consult their physician and the medical implant manu facturer before operating this pump.
Danger! Small parts could be swallowed during assembly and there is a risk of suffocation from the polybag. Keep infants away during assembly.
3. Function
The Electronic Pressure Pump is equipped with an electronic control which automatically turns on the pump when the cut-in pressure has fallen and automatically switches off when no more water is extracted.
Low quantity programme (Leakage Warning):
The low quantity programme allows for trouble-free use of, for example, modern washing machines or drip irrigation systems, even with low water flow. Operating interval: Up to 60 minutes (leakage warning may be triggered after 60 minutes).
Note: The cyclical activation and deactivation of the Electronic Pressure Pump in small amount mode is due to the system design and does not have any impact on pump life.
For irrigation: If the low quantity programme is to be used for
more than 60 minutes, irrigation must be disrupted for at least 5minutes before the end of the 60 minute period. The small amount programme can then be used for a further 60 minutes.
Use of washing machines: Upon completion of the minimum amount water supply cycle in washing machines, the 60-minute operating interval of the low quantity programme is automatically reset to normal operation of the Electronic Pressure Pump and allows a trouble-free use of the washing machine for > 60 minutes.
Info-LED: The pump is equipped with a faults diagnostics system where
various disturbance states can be determined by the Info LED (see 8. Troubleshooting).
16
GB
4. Initial Operation
Positioning of Electronic Pressure Pump:
The installation position must be firm and dry, and permit a secure mounting for the Electronic Pressure Pump.
v Install the Electronic Pressure Pump at a safe distance
(min. 2 m) from the pumping medium.
The pump must be installed in a location with an air humidity of < 80 % and sufficient ventilation in the area of the ventilation slots. It must be at a distance of at least 5 cm from the walls. No dirt contamination (e. g. sand or earth) may be sucked in through the ventilation slots.
Installing the Electronic Pressure Pump:
1
Set up the Electronic Pressure Pump so that it is prevented from slipping and that an appropriately large collecting vessel for draining the pump or the system can be placed under the drain screw 1.
If possible, install the unit higher than the surface of the water to be pumped. If this is not possible, install a vacuum-resistant valve between the unit and the suction hose, for example for cleaning the integrated filter.
If the system is being installed permanently, please fit suitable valves on both the intake and delivery sides. For example, important for maintenance and cleaning work on the pump or for shutdown.
The GARDENA connection pieces on the intake and delivery sides may only be tightened by hand. When using metal connections, damage could occur on the connection thread due to inappropriate assembly. Therefore, screw on the connection fittings with the upmost care.
Connect the hose to the suction side:
Art. 1723 / Art. 1724
4
3
2
Do not use any water hose snap connection system components on the intake side! A vacuum-tight suction hose must be used e. g.:
• GARDENA Suction Hose Art. no. 1411 / 1418
• GARDENA Bore Hole Suction Hose Art. no. 1729.
To reduce the pump repriming time, we recommend:
• Using a suction hose with backflow preventer, which prevents the suction hose emptying automatically when the Electronic Pressure Pump is switched off.
• with larger suction heads, use a suction hose with a smaller diameter (3/4").
1. Connect the vacuum resistant suction hose, sold by the metre
2
, using the suction hose fitting 3 (e. g. Art. no. 1723/1724)
with the connector on the suction side 4 and screw on airtight.
2. For suction heights exceeding 4 m also secure the suction hose
(e. g. by fastening it to a wooden post).
This relieves the pump of the weight of the suction hose.
If very fine dirt is present, we recommend the use of a
GARDENA pump preliminary filter
Art. no. 1730 / 1731
in addition to the integrated filter.
17
GB
Connect hose to output side:
Art. 1752
5
7
8
6
The hose can be connected either to the delivery side 33.3 mm (G 1)-thread of the 120° swivelling connection and / or of the horizontal connection. Art. no. 1757 only has a hori zontal connection. Use pressure-resistant hoses such as:
• GARDENA Garden Hose (3/4") Art. no. 18113 with GARDENA Connection Set Art. no. 1752.
1. For Art. no. 1758 only: Seal the connection not required with
the sealing cap
5
provided.
2. Connect the delivery hose
6
over the connection set 7 with the
connector on the delivery side 8.
If the pump is permanently installed indoors for domestic water supply, the Electronic Pressure Pump should not be connected to the domestic water pipework with rigid pipes but with flexible tubing (e. g. reinforced hoses), to reduce noise and to avoid damage to the pump caused by pressure blows.
5. Operation
Starting the Electronic Pressure Pump:
0
9
ß
A
q
DANGER! Electric shock! Risk of injury due to electric shock! v Before filling the Electronic Pressure Pump,
unplug the equipment from the mains.
1. Unscrew the lid
9
of the filter chamber with the spanner
ß
A
provided.
2. Open any shut-off devices in the delivery line (watering
accessories, tap, etc.) so that air can escape before the priming procedure begins.
3. Empty any water remaining in the delivery hose so that the air
can escape during filling and priming.
4. Fill slowly with water via the filler connection
0
until it overflows (approx. 2 to 3 l), until the water level no longer drops under the suction side inlet.
5. Tighten the lid
9
of the filter chamber up to the stopper.
The specified max. self-priming suction height (see
10. Technical Data) is only achieved if the pump is filled until it overflows from the filter connection
0
and the delivery hose is held high enough during the first self-priming so that no water can escape from the pump via the delivery hose. It is not necessary to hold up the delivery hose if filled suction hoses with backflow preventer are used.
6. Insert mains plug into a 230 V / 50 Hz AC socket.
7. Change the switch
q
to I.
The switch is illuminated and the pump starts after approx. 2 seconds.
8. Close shut-off devices in the delivery pipeline again when the pump begins to continuously convey water.
The pump turns off automatically approx. 10 seconds after closing the shut-off device. The normal operation (Standby) has been reached.