D Gebrauchsanweisung
Zimmerbrunnenpumpe
GB Operating Instructions
Indoor Fountain Pump
F Mode d’emploi
Pompe pour fontaine d’intérieur
NL Gebruiksaanwijzing
Binnenshuis-fonteinpomp
S Bruksanvisning
Pump för inomhusfontän
I Istruzioni per l’uso
Pompa per fontana da interni
E Manual de instrucciones
Bomba para fuente de interior
P Instruções de utilização
Bomba para fontes interiores
DK Brugsanvisning
Springvandspumpe indendørs
Art. 7834
Art. 7835
RP240/RP300/RP420
Art. 7838
RP 600
15
GB
GARDENA Indoor Fountain Pump
RP 240 / RP 300 / RP 420 / RP 600
Welcome to the garden of GARDENA...
Please read these operating instructions carefully and observe
the notes given. Use these operating instructions to familiarise
yourself with the Indoor Fountain Pump, its proper use and the
notes on safety.
For safety reasons, children under the age of 16 and people
not familiar with these operating instructions must not use this
Indoor Indoor Fountain Pump.
v Please keep these operating instructions in a safe place.
1. Where to Use Your GARDENA Indoor Fountain Pump
. . . . . . . 15
2. Safety instructions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3. Initial Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4. Storage
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5. Cleaning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6. Troubleshooting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7. Accessories
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8. Technical data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
9. Service / Warranty
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Contents:
16
GB
1. Where to Use Your GARDENA Indoor Fountain Pump
GARDENA Indoor Fountain Pumps have been designed for private use around your house.They are not designed for operating
watering tools and systems. Pumps RP 240 / RP 300 / RP 600
must only be used indoors. Pump RP 420 is part of Fountain Set
Art. 7767 and is suitable for outdoor use.
GARDENA Indoor Fountain Pumps have not been designed
for constant use in the industrial sector. Corrosive, easily
combustible, aggressive or explosive substances (e.g.
petrol, petroleum, nitro thinner) as well as saltwater or food
/ drinking water must not be pumped.
Correct use:
Please note:
2. Safety instructions
Electrical safety:
DANGER! Electric shock !
VV
Always disconnect the fountain
pump from the mains before
undertaking any work.
The pump should be operated via a residual
current device with a residual current rating of
≤ 30 mA (DIN VDE 0100-702 and 0100-738).
The pump must be placed on solid, even
ground.
v Please consult a qualified electrician for
advice.
17
GB
Mains power cables must not have a smaller
cross-section than a PVC cable of the
designation H03 VV (RP 420 of the
designation H05 RNF). Extension cables must
meet the requirements of DIN VDE 0620.
Data indicated on the type plate must match
technical data of the mains supply.
Please unplug the fountain pump after
operation and before carrying out any
maintenance works.
The fountain pump must not be operated
when there are people in the water.
Swimming pools and garden ponds should
be designed according to international and
national design regulations.
v Please consult a qualified electrician for
advice.
Before operating the fountain pump, look to
see if there is any damage to the fountain
pump (esp. regarding power cable and plug).
The connection cable of the pump cannot be
replaced. If the cable is damaged the pump
must be disposed of.
Do not use the power cable to carry the pump
or to pull the plug out of the socket.
Protect the power cable from heat, oil and
sharp edges.
For Austria:
Pumps for use in swimming pools and
ponds may only be operated via an isolating
transformer.
v Please consult a professional electrician.
For Switzerland:
In Switzerland mobile appliances which are
used outdoors must be connected via a
residual-current device.
User instructions:
Never let the pump run dry; running
dry generates heat and will damage
the pump.
18
GB
The temperature of the liquid used must not
be below 4 °C or above 35°C.
Sand and other abrasive substances in the
liquid cause increased wear and reduce the
output of the pump.
Please observe the local noise prevention
regulations.
3. Initial Operation
1. RP 600 : Insert the fountain socket 1and nozzle tube 2.
2. Install the pump at ground level so that the filter housing
is standing in water to at least half its height (with pumps
RP 240 / RP 300 / RP 420 make sure that the sides of the
foam filter under the pump are not blocked).
3. Plug mains plug into an AC power socket.
Warning: Pump will start immediately.
4. Use the flow control
3
to set the desired water flow for the
fountain pump.
Starting up the pump:
1
2
3
RP 240
RP 300
RP 420
RP 600
19
GB
If the pump is installed out of water, the filter housing4must
be taken off.
1. Pull off the filter housing
4
.
2. Turn the pump inlet
5
anticlockwise and pull it vertically off
the motor housing 6(bayonet socket).
3. Depending on the pumping application, the pump inlet can be
rotated in 90° steps. Twist the pump inlet
5
accordingly, again
press it vertically on to motor housing 6and tighten it clockwise (see 5. Cleaning).
4. Screw stepped nipples
7
on to the pump inlet 5and pump
outlet 8.
5. Connect the pump inlet
5
to the water reservoir with a hose
(1/2
"
or 3/4
"
). The level in the water reservoir must be
higher than the pump inlet5.
6. Connect the pump outlet
8
to the spring / gargoyle with a hose
(1/2
"
or 3/4
"
).
7. Fill the hose to the pump inlet
5
with water.
8. Insert the pump plug into a mains socket.
Caution: The pump will start immediately.
9. Use the flow control
3
to set the desired water flow for the
spring.
Commissioning the pump if
it is installed out of water:
5
3
4
6
7
8