Ganz ZP-EPC10 Installation Manual

Installation Guide
Protocol converter
ZP-EPC10
Always read this manual before installing,
starting up, operating, storing or otherwise handling any part of the system.
This installation guide, edition 01 – 05/2000, is valid for use with the
Contents
Introduction
Intended use 4 EU directives 4 Identification plate 4
Safety Measures
Danger by Electric Current 5 Installation 5 Repair and Maintenance 5
Product Description
Scope of supply 6 Recommended Accessories 6 Summary of features 6 Connections and Switches 7
Installation
Connections 8 Configuration 10 Switching on and off 12 Function test 12
Care and maintenance
Cleaning 13 Maintenance 13 Passing on, Waste Disposal 13
Appendix
Conversion table for hexadecimal addresses 14 Typical system configurations 15 Meaning of function keys 18 Troubleshooting 19 Technical data 19
4
ZP-EPC10
Introduction
This installation guide is designed for the use of persons concerned with the installation and configuration of the protocol converter and any devices connected to it. Relevant international, national and – if applicable – local electronic engineering standards should be observed at all times.
Intended use
The ZP-EPC10 protocol converter is designed to provide an interface between the CEC C328 matrix switcher and the dome cameras of the SMD series from CBC. The device converts the data transfer between protocols RS422 and RS485. The unit is designed exclusively for this function. No other application is permitted.
For further information on operating aspects that are not covered in this guide, please contact us at:
CBC (Deutschland) GmbH
Hansaallee 191 D – 40549 Düsseldorf
Phone: +49 (0) 211 53 06 70 Fax: +49 (0) 211 53 06 71 80
EU directives
The ZP-EPC10 protocol converter fulfils the specifications of European Union directive 89/336 (covering electromagnetic compatibility).
Identification plate
Precise identification of each unit is provided by the plates attached to the front and rear of the housing, which show the model designation and serial number. Keep these details for reference, should you have questions or for ordering spare parts.
Model:
Serial Number:
Implementation
CBC (Europe) Ltd.
7/8, Garrick Industrial Centre, Irving Way GB – London NW9 6AQ
Phone +44 (0) 181 732 3310 Fax +44 (0) 181 202 3387
ZP-EPC10
5
(05/2000)
Security Measures
Safety Measures
Danger by Electric Current
• The device must be connected to the appropriate power supply.
• Only use a suitable adaptor (see technical data).
• Disconnect the adaptor from the mains supply when an error occurs.
• Only use the adaptor and device in a dry, weather protected environment.
• If safe application of the device is no longer guaranteed, it should not be used but be protected against inadvertent handling. Safe use is no longer possible, e.g.
– when the device or cables are visibly damaged, – when the device does not work properly, – when the device has been exposed to rain or wet conditions, – when the item has been pierced, – after prolonged storage in unfavourable conditions or after difficult transportation.
Have the device checked by CBC.
Installation
• When installing the device, electrical engineering regulations should be adhered to.
• Follow the instructions for installation and operation other equipment, e.g. cameras. These instructions contain important advice on safety and approved use of equipment.
• Carefully follow guidelines for installation and use. Not doing this could lead to personal injury, damage to property or to the equipment itself.
Repair and Maintenance
• Never open the housing of the protocol converter. The device does not contain parts that you can repair or replace yourself.
• Ensure that repair or maintenance work is carried out by qualified personnel (electrical engineers).
6
ZP-EPC10
Product Description
Scope of supply
Protocol converter ZP-EPC104 screw clampsInstallation guide
Recommended Accessories
CV12 power supply available from CBCCable made to Belden specifications
Summary of features
The ZP-EPC10 protocol converter is designed to convert control signals between RS422 (full-duplex) and RS485 (half-duplex) protocol. In addition to adjusting for diffe­rent pin assignments, the unit also converts the protocols used by the CEC C328 video multiplexer and the SMD-type dome cameras manufactured by CBC. A single protocol converter can support up to 31 dome cameras. It is also possible to cascade up to nine protocol converters to control a maximum of 256 dome cameras using a single multi­plexer.
Both SMD-type and CEC VSD-type dome cameras (only the former use RS485 proto­col) may be operated jointly.
The following dome camera functions are supported:
Pan, tilt, zoom, focus, irisPresetsWriting EEPROMStart position (Home)Auto-focus, auto-iris, manual iris controlAutomatic pan or tilt function between presets 1 and 2Control of pan and tilt speedCamera speed control
Note:
Observe the examples and explanations given from page 15 onwards.