Galaxy Raid Installation and Hardware Reference Manual
Trademarks
Galaxy and the Galaxy logo are registered trademarks of Rorke Data , Inc.
®
PowerPC
Motorola Inc.
Solaris and Java are trademarks of Sun Microsystems, Inc.
All other names, brands, products or services are trademarks or registered
trademarks of their respective owners.
is a trademark of International Business Machines Corporation and
iii
Galaxy Raid GHDX2-2430S/R-24F4DInstallation and Hardware Reference Manual
Warnings and Certifications
Restricted Access Location:
This equipment is intended to be installed in a RESTRICTED ACCESS LOCATION only.
Electric Shock Warning!
To Prevent Electric Shock:
Access to this equipment is granted only to trained operators and service personnel who have
been instructed of and fully understand the possible hazardous conditions and the
consequences of accessing non-field-serviceable units. For example, accessing the backplane
may cause electric shock.
FCC (applies in the U.S. and Canada)
FCC Class A Note
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device may accept any interference received, including interference
that may cause undesired operation.
NOTE:
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residen tial area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.
The changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
WARNING:
iv
Galaxy Raid Installation and Hardware Reference Manual
Use only shielded cables to connect I/O devices to this equipment.
You are cautioned that changes or modifications not expressly approved by the
party responsible for compliance could void your authority to operate the
equipment.
This device is in conformity with the EMC.
CB
This device is in conformity with the CB safety specifications.
This device meets the requirements of the CB standard for electrical
equipment with regard to establishing a satisfactory level of safety for
persons using the device and for the area surrounding the apparatus.
This standard covers only safety aspects of the above apparatus; it does
not cover other matters, such as style or performance.
CCC for Power Supplies’ compatibility to China Compulsory Certification.
This device is in conformity with UL standards for safety.
ITE BSMI Class A, CNS 13438 (for Taiwan)
v
Galaxy Raid GHDX2-2430S/R-24F4DInstallation and Hardware Reference Manual
This device is in conformity with UL standards for safety.
RoHS 2002/96/EC compliant
WEEE Disposal of Old Electrical and Electronic Equipment
vi
Galaxy Raid Installation and Hardware Reference Manual
C.5.ETHERNET PORT PIN OUTS..................................................................................... C-6
C.6.MAIN POWER ......................................................................................................... C-6
x
Safety Precautions
Precautions and Instructions
•Prior to powering on the subsystem, ensure that the correct power range is being
used.
•The Galaxy subsystem comes with twenty four (24) drive bays. Leaving any of th ese
drive bays empty will greatly affect the efficiency of the airflow within the
enclosure, and will consequently lead to the system overheating, which can cause
irreparable damage.
•If a module fails, leave it in place until you have a replacement unit and you are
ready to replace it.
•Airflow Consideration: The subsystem requires an airflow clearance, especially at
the front and rear.
Galaxy Raid Installation and Hardware Reference Manual
•Handle subsystem modules using the retention screws, eject levers, and the metal
frames/face plates. Avoid touching PCB boards and connector pins.
•To comply with safety, emission, or thermal requirements, none of the covers or
replaceable modules should be removed. Make sure that during operation, all
enclosure modules and covers are securely in place.
•Be sure that the rack cabinet into which the subsystem chassis will be installed
provides sufficient ventilation channels and airflow circulation around the
subsystem.
•Provide a soft, clean surface to place your subsystem on before working on it.
Servicing on a rough surface may damage the exterior of the chassis.
• If it is necessary to transport the subsystem, repackage all disk drives separately.
• Dual redundant controller models come with two controller modules that must be
installed into the subsystem. Single controller modules come with a single controller
module and a metal sheet is placed over the lower controller bay at the rear of the
subsystem. Since single controller modules cannot be upgraded, this metal sheet
should NEVER be removed.
ESD Precautions
Observe all conventional anti-ESD methods while handling system modules.
The use of a grounded wrist strap and an anti-static work pad are recommended.
Avoid dust and debris in your work area.
xi
Galaxy Raid GHDX2-2430S/R-24F4DInstallation and Hardware Reference Manual
About This Manual
This manual:
•Introduces the Galaxy RAID GHDX2-2430S/R-24F4D 400mhz ASIC
subsystem.
• Describes all the active components in the subsystem.
• Provides recommendations and details about the hardware installation
process.
• Briefly describes how to monitor the subsystem.
• Describes how to maintain the subsystem.
This manual does not:
• Describe components that are not user-serviceable.
• Describe the configuration options of firmware, using terminal emulation
programs, or the RAIDWatch GUI software that came with your subsystem.
•Give a detailed description of the RAID controllers embedded within the
subsystem.
Revision History
♦ Initial release
Who should read this manual?
This manual assumes that its readers are experienced with computer hardware
installation and are familiar with storage enclosures.
Related Documentation
• User’s Operation Manual
• RAIDWatch User’s Manual
xii
These two documents can be found in the product utility CD included with yo ur
subsystem package.
Conventions
Naming
From this point on and throughout the rest of this manual, the Galaxy series is
referred to as simply the “subsystem” or the “system” and Galaxy is frequently
abbreviated as “Gal.”
Lists
Bulleted Lists: Bulleted lists are statements of non-sequential facts. They can be
read in any order. Each statement is preceded by a round black dot “•.”
Numbered Lists: Numbered lists are used to describe sequential steps you
should follow in order.
Galaxy Raid Installation and Hardware Reference Manual
Important information that users should be aware of is indicated with the
following icons:
NOTE:
These messages inform the reader of essential but non-critical
information. These messages should be read carefully as any directions
or instructions contained therein can help you avoid making mistakes.
CAUTION!
Cautionary messages should also be heeded to help you reduce the
chance of losing data or damaging the system.
IMPORTANT!
The Important messages pertain to use the Galaxy subsystem introduced
in this manual.
Warnings appear where overlooked details may cause damage to the
xiii
WARNING!
Galaxy Raid GHDX2-2430S/R-24F4DInstallation and Hardware Reference Manual
equipment or result in personal injury. Warnings should be taken
seriously.
Software and Firmware Updates
Please contact Rorke Technical Support for the latest software or firmware
updates.
Problems that occur during the updating process may cause unrecoverable errors
and system down time. Always consult technical personnel before proceeding
with any firmware upgrade.
NOTE:
The firmware version installed on your system should provide the
complete functionality listed in the specification sheet/user’s manual.
We provide special revisions for various application purposes.
Therefore, DO NOT upgrade your firmware unless you fully understand
what a firmware revision will do.
xiv
Galaxy Raid Installation and Hardware Reference Manual
xv
Chapter 1
Introduction
1.1. Product Overview
This hardware manual briefly introduces the Galaxy GHDX2-2430S/R-16F4D Fibre-4G
to SATA-II RAID subsystem as shown in Figure 1-1.
The GHDX2-2430S-24F4D RAID subsystem is powered by a single RAID controller,
the GHDX2-2430R-24F4D by dual redundant RAID contro llers. Each RAID controller
comes with two (2) 4Gbps Fibre host channels that are interfaced through four (4)
separate SFP ports. A total of eight (8) SFP ports are available in a redundant-controller
configuration. The additional SFP ports facilitate connection to multiple application
servers and for connecting fault-tolerant data paths. The subsystem houses twenty-four
(24) 3Gbps SATA-II disk drives each with dedicated channel bandwidth. Each controller
board comes with a pre-installed 512MB DDR RAM DIMM module and can support
memory modules with the capacities up to 2GB.
The Galaxy HDX2 series is built around a custom ASIC400 specifically designed with
the hardware RAID6 capability. RAID6 can sustain two member drives of a RAID array
to fail at the same time and thereby helps achieve a higher level of data availability.
There are six (6) dedicated RCC paths strung between the partner RAID controllers in a
dual-active configuration. The RCC chips reside on the third, separate PCI-X bus. This
design takes benefits of the abundant system bandwidth brought by the new architecture
and hence the inter-controller communications do not affect drive channel throughput.
Introduction 1-1
Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual
A SAS expansion port comes with each RAID controller and provides easy connectivity
to terabytes of expansion capacity over the 4x, wide SAS link cables.
Two (2) RS-232C (audio jack) serial port connectors are located on the controller
faceplate. One serial port (COM1) enables serial communication between the controller
and an external PC running terminal emulation software that can be used to configure and
manage the RAID subsystem. The second serial port (COM2) connects to an
uninterruptible power supply (UPS). An RJ-45 Ethernet connector allows telnet access
and web-based management using the included browser-based or Java-based versions of
the RAIDWatch manager software.
Disk drives in the front section of the subsystem are directly mated with a common
backplane. The backplane receives a maximum of twenty-four (24) SATA-II hard drives
that should be separately purchased.
Two (2) redundant, hot-swappable, dual-fan cooling modules protect the RAID
subsystem from overheating and three (3) redundant, hot-swappable, 1U 405W power
supply unit (PSU) modules provide constant power to the RAID subsystem. The modular
nature of the subsystem and the easy accessibility to all major components ensure that the
subsystem can be reliably and efficiently operated and maintained.
1.1.1 Enclosure Chassis
1.1.1.1 Chassis Overview
The Galaxy HDX2 24bay subsystem comes with a 4U compact steel chassis and
aluminum alloy framework for even distribution of component heat. A back-end PCB is
enclosed in thick gauge sheet metal that divides the enclo sure intern ally into th e front and
rear sections. (See Figure 1-2) The front section accommodates twenty-four (24) drive
trays (with their associated hard drives) and the rear section accommodates three (3) PSU
modules, two (2) dual-fan cooling modules, and RAID controllers in a single- or dualcontroller configurations. The two (2) foldable handles on the front of the chassis enable
you to easily extract the chassis from a rack cabinet. The subsystem enclosure can be
mounted into standard 19-inch rack cabinets using separately purchasedslide rails.
1-2
Introduction
Chapter 1: Introduction
Figure 1-2: Galaxy 24-bay SATA RAID Subsystem Overview
1.1.1.2 Physical Dimensions
The Galaxy HDX2 24bay subsystem comes in a standard 4U chassis with the following
dimensions:
♦ With forearm handles: 482W x 174.4H x 514D mm (19 x 6.87 x 20.2 inches)
♦ Without forearm handles: 445W x 174.4H x 498D mm (17.5 x 6.87 x 19.6
inches)
1-3
Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual
1.1.1.3 Front Panel Overview
Figure 1-3: Galaxy HDX2 24bay RAID Subsystem Front View
As shown above, the front section of the subsystem features a 4-column by 6-row layout
to accommodate twenty-four (24) drive trays that are designed to house standard 3.5-inch
SATA drives. The left-side forearm handle comes with a 16 characters by 2 rows LCD
screen and four (4) function keys that can be used to configure and monitor the
subsystem.
1.1.1.4 Drive Slot Numbering
The front section of the enclosure houses twenty-four (24) hard drives. When viewed
from the front, the drive bays (slots) are numbered 1 to 24 from left to right, then from
top to bottom.
The rear panel of the Dual redundant controller version of the Galaxy HDX2 subsystem
is shown in Figure 1-5. The rear panel provides access to all the components located in
the rear half of the RAID subsystem enclosure. The rear panel of the single controller
version of the Galaxy HDX2 subsystem is shown in Figure 1-5.
Three (3) (N+1) redundant, hot-swappable 405W PSU modules provide converted power
from the power source. Two (2) redundant, hot-swappable, dual-fan cooling modules are
located above the PSU modules. One power switch on the chassis rear panel controls all
PSU modules. Each PSU module contains two cooling fans.
Figure 1-6: Galaxy GHDX2-2430S-24F4D Rear View
1-5
Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual
Each RAID controller module comes with four (4) SFP host ports, two (2) RS-232C
(audio jack) serial ports, one (1) RJ-45 Ethernet connector and status-indicating LEDs
located on its rear-facing faceplate.
1.1.1.6 The Backplane Board
An integrated backplane board receives disk drives on the front end and connects the
RAID controller, cooling, and PSU modules on the other side. The PCB board provides
logic level signals and low voltage power paths. It contains no user-serviceable
components.
1.1.1.7 Subsystem Rack/Cabinet Installation
The subsystem chassis has pre-drilled screw holes for rackmounting. Separately
purchased, independently installed rackmount rails are available for rack or cabin et
installation.
The slide rails come with their own printed copies of installation guide.
1.2. Subsystem Components
1.2.1 LCD Keypad Panel
Figure 1-7: LCD Keypad Panel
The LCD keypad panel consists of an LCD display with push buttons and LEDs that
indicate array statuses. The LCD panel provides full access to all RAID configurations
and monitoring options. After powering up the subsystem, the initial screen will display
1-6
Introduction
the subsystem model name. A different name can be assigned for the subsystem or
specific logical drives. This enables ease of identification in a topology consisting of
numerous arrays.
1.2.2 Drive Trays
The subsystems’ twenty-four (24) drive trays accommodate separately purchased,
standard 1-inch pitch, 3.5-inch disk drives. The drive bays are accessed through the front
of the enclosure. Two (2) LEDs on each tray bezel indicate the disk drive’s operation
status. A rotary bezel lock on each drive tray secures the hard drive in place, while a
release button can be used to open the front bezel.
Chapter 1: Introduction
Figure 1-8: Drive Tray
WARNING!
Be careful not to warp, twist, or contort the drive tray in any way (e.g., by dropping
it or resting heavy objects on it). The drive tray has been customized to fit into th e
drive bays in the subsystem and if it is deformed or altered it may not fit into the
drive bay.
NOTE:
The redundant-controller subsystem is shipped with twenty-four drive trays with
multiplexer (MUX) adapter boards. These MUX boards provide access routes for
different RAID controllers.
Please DO NOT use drive trays from a previous Galaxy model, GHDX-7376R624F2D. They are not compatible.
1.2.3 RAID Controller Module
The RAID controller module contains a main circuit board and a daughter card providing
additional interface connectors, management and host interfaces, and a preinstalled
512MB DDR RAM DIMM. The subsystem comes standard with BBU protection. The
BBU is installed in the module bay located at the top center of the controller module. The
BBU can be independently inserted or removed. Please note: The controller module
1-7
Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual
contains no user-serviceable components. Only remove the controller when replacing a
faulty unit or installing/ the cache memory inside.
WARNING!
Although the RAID controllers are hot-swappable, the only time you should handle
the controller itself is to remove a failed controller, or to install and replace
memory modules. Unnecessary tampering with the RAID controller can damage
the controller.
Figure 1-9: RAID Controller Faceplate
The controller faceplate provides external interfaces including four (4) SFP host ports,
two (2) RS-232C (audio jack) serial ports (labeled COM1 and COM2), one (1) RJ-45
Ethernet connector and six (6) status-indicating LEDs (labeled from 1 to 6), one Restore
Default LED and the associated push button. The controller main circuit board is hou sed
in a metal canister and can only be seen after the controller is removed from the chassis.
The controller canister has two (2) ejection levers that can be used to retrieve or secure
the controller module to the chassis. These levers are secured to the enclosure chassis
using two (2) retention screws through the screw holes underneath each lever.
1.2.4 Controller Module Interfaces
All host I/O and management interfaces are located on the controller faceplate. The
interfaces are listed below.
SFP host ports: Host ports are SFP sockets that receive 4Gb/s interface fiber optical
transceivers. It is recommended to use only certified transceivers and cables.
SAS expansion port: The SAS expansion port provides a 12Gb/s wide link to the
Galaxy series expansion JBODs.
RS-232C (Audio Jack): All controller modules come with two (2) RS-232C (audio
jack) serial ports The serial ports can be used for establishing a management session
through terminal emulation and uninterruptible power supply ( UPS) support.
1-8
Introduction
Chapter 1: Introduction
The dual-controller subsystem comes with a serial port Y-cable that allows you to
access a surviving controller in the event of controller failure without physically
changing the connection.
TIPS:
Connect both Ethernet ports (if you are using a dual-controller subsystem) to
the Ethernet ports of your network switch.
The Ethernet port on a non-dominant (secondary) controller will stay idle until
the occurrence of primary controller failure.
Ethernet port: A single 10/100BaseT Ethernet port is used for local/remote
management over LAN/WAN. For a dual-controller configuration, connect the
Ethernet ports on both RAID controllers to your local network. The Ethernet port on
a non-dominant (stand-by, usually the controller in the lower slot) controller will
remain idle until a dominant, primary controller fails and the management service is
transferred to the surviving controller.
Disk Drive Channels: All models come with twenty-four (24) SATA drive channels
that are interfaced thorough a backplane to the hard disk drives.
1.2.5 DIMM Module
Each controller module comes with a preinstalled 512MB DDR RAM DIMM module
mounted on the controller board within a metal chassis. The controller module supports
memory modules with sizes from 512MB to 2GB.
1.2.6 BBU Module
The BBU can sustain cached data for days during a power failure. If power outage
occurs, the BBU supplies power to sustain the unfinished writes in cache memory.
1-9
Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual
Figure 1-10: BBU Module, Controller Top Cover, and the Module Slot
The BBU functionality consists of two major parts. One is the charger circuitry mounted
on top of the controller main board. The other is an optional BBU module that contains
several battery cells. On a single-controller configuration, the BBU is an optional
accessory. The BBU module is hot-swappable so it can be replaced while the subsystem
is running.
New Feature:
The battery cell packs come with an EEPROM to record the date of installation and other
service data; and when the appro ximate on e-year life expectancy is reached (by checking
against the real-time-clock), system administrators will be notified for replacing the
BBU.
In accordance with international transportation regulations, the BBU is only charged to
between 35% and 45% of its total capacity when shipped. After powering on the
subsystem (see Section 4.1) the BBU will automatically start charging its battery cells. It
usually requires approximately twelve (12) hours for the battery to be fully charged.
The BBU is aware of its life expectancy as well as its charge level. Charge level
awareness helps avoid frequent re-charge.
1.2.7 Power Supply Units
The subsystem is equipped with three (3) hot swappable, 1U-profile, 405W PSU
modules. The PSU modules are located on the rear panel of the subsystem.
1-10
Introduction
Chapter 1: Introduction
Figure 1-11: PSU Module
Each PSU module comes with a power socket for power cord plug-in. All three power
supplies are turned on and off using a single powe r switch on th e enclos ure chas sis. Each
PSU also comes with two (2) embedded cooling fans to provide sufficient airflow across
its heat-generating components and one (1) LED to indicate the PSU status. An extraction
handle makes it easier to install or remove the PSU from the subsystem. While a PSU
may be removed when the system is still online, this should only be done if the PSU has
failed and needs to be replaced.
A retention screw through the extraction handle secures the PSU to the chassis. If the
PSU needs to be removed, the retention screw must be removed first. After installing a
new PSU module, make sure that the retention screw has been firmly secured. The
shipping package contains adjustable cable clamps that can be used to secure power cord
connections.
PSU specifications are shown in Appendix A.
Power Supply Safety Restrictions
No. of Failed PSUs Responses and Preventive Actions
1. Warning messages are issued.
2. Cached data is flushed to the hard drives (also depends on
the Event Triggered configuration settings of the
1
firmware).
3. If previously configured to the Write-back mode, the
caching mode is automatically switched to the
conservative Write-through mode.
1-11
Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual
1. Warning messages are issued.
2. The subsystem is temporarily held in an idle state.
3. The firmware forces the subsystem to stop serving host
I/O requests.
2
4. After the failed PSUs are replaced, array administrators
should manually turn the power switch off and then on.
5. If the subsystem is powered on with only one PSU, the
firmware will start the initialization process but stays idle
until at least one other PSU is added.
Table 1-1: Power Supply Safety Restrictions
1.2.8 Cooling Modules
These Galaxy 24 bay subsystems come with two (2) hot swappable, redundant, dual-fan
cooling modules. Two (2) 8cmblowers are housed in each cooling module and provide
ventilation airflow from the front to the rear of the subsystem, extracting the heat
generated by the SATA hard drives and other components.
Intelligent Dual Speed Operation
The fans in the cooling module operate with two rotation speeds. Under normal operating
conditions, the cooling fans run at the low speed, which is sufficient for maintaining an
efficient airflow across components. Under the following conditions, the cooling fans
automatically increase their rotation speed to increase the airflow:
1. Component Failure: if a cooling fan, PSU, or temperature sensor fails, the
remaining cooling fan(s) automatically raises its rotation speed.
2. Elevated Temperature: if the temperature breaches the upper threshold set for any
of the interior temperature sensors, the cooling fans automatically raise its rotation
speed.
3. During the initialization stage, the cooling fans operate at the high speed and
return to low speed once the initialization process is completed and no erro neous
condition is detected.
1-12
Introduction
1.2.9 Enclosure DIP Switches
Chapter 1: Introduction
Figure 1-12: Cooling Module
DIP switches are located on the upper left corner of enclosure rear panel. The first tree
switches determine an enclosure ID and should always be kept at their default, “0-0-0.”
The two (2) switches marked as #7 and #8 have no function. The #4 switch is for
controlling the onboard hub across the host ports on partner controllers, to enable/d isable
the onboard bypass. Switch #4 is only applicable in a dual-controller configuration.
Switches #5 and #6 control host channel 4G or 2G speed.
When the onboard hub is enabled, host channels on the partner controllers will be
combined, e.g., Channel 0 on Controller A and Channel 0 on Controller B combined into
a host loop. Using the onboard hub enables fault-tolerant host links without the use of
expensive FC switches in a DAS (Direct Attach Storage) topology.
The configuration options for setting the DIP switches is fully discussed in Chapter 4.
Figure 1-13: Enclosure DIP Switches
1-13
Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual
1.3. Subsystem Monitoring
The RAID subsystem comes with several monitoring methods to give you constant
updates on the status of the system and its individual components. The following
monitoring features are included in the subsystem.
1.3.1 I2C bus
The following subsystem elements interface to the RAID controller over a non-userserviceable I
Firmware: The firmware (FW) is pre-installed software that is used to configure the
subsystem. The FW can be accessed through either the front panel LCD keypad or a
terminal emulation program that is installed on an external computer/application server
used as a management station.
1-14
Introduction
RAIDWatch: RAIDWatch is a premier, web-based or Java-based graphical user
interface (GUI) that can be installed on an adjacent or a remote computer and accessed
via standard TCP/IP.
1.3.4 Audible Alarm
The RAID subsystem comes with audible alarms that are triggered when certain active
components fail or when certain controller or subsystem thresholds are exceeded. When
you hear an audible alarm emitted from the subsystem, it is imperative that you determine
the cause and rectify the problem immediately.
WARNING!
Failing to respond when an audible alarm is heard can lead to permanent
subsystem damage. When an audible alarm is heard, rectify the problem as soon as
possible.
Chapter 1: Introduction
1.4. Hot-swappable Components
1.4.1 Hot-swap Capabilities
The subsystem comes with hot-swappable components that can be exchanged while the
subsystem is still online without affecting the operational integrity of the subsystem.
These components should only be removed from the subsystem when they are being
replaced. At no other time should these components be removed from the subsystem.