Model 7335-004 Outdoor Non-metallic
Confidentiality Notice
This ma nual is p rovided solely as an operat ion, inst allation, and maintena nc e gu ide and contains sens itive bus ines s and t echnic al infor ma tion tha t is confident ial and prop rieta ry to GAI - Tr onic s. GAI- Tr onic s retains all intellectual prop erty a nd other r ights in or to the information contained herein, and s uch infor ma tion may only be used in connection with t he op erat ion of your GAI-T ronics produ c t or s ystem. This manu al may not be disclos ed in any form, in whole or in pa rt, direct ly or indirectly, t o any third party.
General Information
The Model 7335-004 Outdoor Non-metallic E mer gency Party Line Amplifier Enclos ure is des igned t o be a component in a GAI-Tronics SmartSeries system. It is a multi-party, 115 V amplifier enclosure that mates with a Model 701-80x or 701-90x Series Handset/Speaker Amplifier to form a SmartSeries station.
When connected to a SmartS eries sys tem, this sta tion is equip ped to rep ort t he following inf ormation when the handset is t aken off-hook:
Zone number
Station address
Pa rty line (1 or 2)
All station r ep orts are received by the Master Control Unit and annu nc iated on a n access panel located in the SmartSeries control cabinet.
OTES:
N
1. The Model 7335-004 Enclosure can also mate with a standard 701 or 751 Series Amplifier; however the reporting feature is not op erab le wit h this combination.
2. E mer gency party line func tionalit y is only possible if your sys tem’s software is properly configured. Your system must also have the address of the s tat ion intended to mat e wit h the enclosure enabled. Should you have qu es tions a s to the capabilities of your s ystem, please contact your nea rest G AI - Tr onic s Servic e Center.
GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA
610-777-1374 800-492-1212 Fax : 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V
Page 2
Pub. 42004-623L2A
Model 7335-004 Multi-Party Emergenc y P ar ty Line Amplifier Enclosure Page:
Installation
2 of 8
CAUTION
indicated on the approval list ing in the Sp ec ification section of this manual. Such installation may cause a safety hazard and consequent injury or property damage.
When installing an add-on st ation, consult the sys tem layout diagrams at the end of this ma nual. These figures, when used in conjunct ion with the st ation ins tallation information and cable layout guide, should provide all the infor ma tion necessary to insta ll additional Pa ge/ Party< stations.
Do not install this equipment in hazardous areas or areas other than those
Enclos ure Placement
All GAI-Tronics Pa ge/ Party® units are wired in parallel. G ood system layout design minimizes the cable required for ea ch insta llation. GAI-Tronics multi-condu c tor cable, des igned especially for this applic ation, is recommended. The number, size, and color-coding of condu c tors are lis ted in the acc ompanying sys tem connection diagra ms .
System layout and power c able length are ver y important when inst alling Page/Party< equipment. Although it vari es f or differ ent systems, the general guideline is t hat t he t otal p ower cable length should not exceed one mile (5280 feet) for 115 V ac systems. The total cable length is the most important consideration while cable length between the sta tions is generally not a fa c tor.
Mounting
The Model 7335-004 Outdoor Non-metallic E PL Amplifier Enclosure is not supp lied wit h openings for conduit or cable becau se the pla c ement will vary acc ording to t he a pplica tion. Drill or punch thes e openings us ing the template supplied before mounting the enclosure. We highly recommend using only the bott om entry to p revent moisture from dripp ing onto the terminals or PC B As. The best loc ation for conduit holes is a long the bottom of the enclosure near the rear su rfa c e. If the top opening is to be used, c arefully seal around the fitting to prevent moisture from entering.
For specific details including mounting hole dimensions, refer t o Figur e 1 . There ar e fou r 7/ 16-inch diameter mounting holes in the corners of the amplifier enclosure. The suggested mounting height for a ll station enclosures is 54 inches (137 cm) to the centerline of the enclosure.
OTE: Labels denoting whic h party line(s) is configured as the emergency party line are included in a n
N
envelope inside the enclosu re. The labels ar e f or Part y Line 1, Party Line 2 , and Party Lines 1 and 2 configurat ions. Ap ply the appr op ria te label ins ide you r enclosu re.
\\s_eng\gtc proddoc s \ s t andard iom s - current release\42004 inst r. m anuals \ 42004-623l2a. doc
10/03
Page 3
Pub. 42004-623L2A
Model 7335-004 Multi-Party Emergenc y P ar ty Line Amplifier Enclosure Page:
3 of 8
Figure 1. Outdoor Enclosur e M ounting
\\s_eng\gtc proddoc s \ s t andard iom s - current release\42004 inst r. m anuals \ 42004-623l2a. doc
10/03
Page 4
Pub. 42004-623L2A
Model 7335-004 Multi-Party Emergenc y P ar ty Line Amplifier Enclosure Page:
4 of 8
Wiring
Attach the conduit to the enclosure. F eed the wiring through the condu it and b ring it into the enclosu re. See Figu re 2. Follow the wir e colors carefully beca use the colors correspond to GAI- Tronic s 60029 Series multi-p arty cab l e. The wir es mu st be s pade-lugged and connected s ecurely to the termina l block. An improper termination ca n result in diminished station performa nc e.
Local Muting
Figure 2 illus trates local speaker muti ng when stat ions are completely assembled and paging operation occurs. N ormally, when t he s tation but ton is pressed, the paging spea ker connected t o that sta tion is silenced (muted) to pr event acoustic feedback to the handset microphone. H owever, while the handset is in use for party line conversations, the paging speaker is “live” t o enable pa ging c alls from other s tat ions.
To d i sa ble th e mute f eatur e, fol l o w thes e i n struction s:
1. Locate the lugged violet wire attached to terminal point 7 (mute) on the terminal block within the
enclosure.
2. Transf er the lugged violet wire to terminal point 8 (Page L1). After any muting changes a re made, u npack the sta tion amplif ier and ins tall.
Mutual Muting
In the event that f eedback occu rs within an a rea and repositioning of the system speaker s does not help, mutual muting may be used to correct this problem.
The following steps will mutu ally mute the adjacent amplifiers /hands et s within a z one.
1. Ensure that the p u rple lugged wire is connect ed t o terminal 7 of TB 1 .
2. Connect terminal TB1- 7 of the ha ndset stat ion to TB1 -7 of t he s tat ion within the zone that is c ausing
feedback. This is done by u sing the sp are s ystem wire (orange conduc tor) f rom within the s ystem ca ble t h at ru n s between th e stat i o n s.
\\s_eng\gtc proddoc s \ s t andard iom s - current release\42004 inst r. m anuals \ 42004-623l2a. doc
10/03
Page 5
Pub. 42004-623L2A
Model 7335-004 Multi-Party Emergenc y P ar ty Line Amplifier Enclosure Page:
5 of 8
Figure 2. Wiring Diagram
\\s_eng\gtc proddoc s \ s t andard iom s - current release\42004 inst r. m anuals \ 42004-623l2a. doc
10/03
Page 6
Pub. 42004-623L2A
Model 7335-004 Multi-Party Emergenc y P ar ty Line Amplifier Enclosure Page:
6 of 8
Maintenance
Regula r insp ection and a good pr eventive maintenance program will increase the relia bility of you r GAI-Tronics station. The GAI-Tronic s Field Service Depa rtment can formulate a service cont rac t suited to your fac ility’s s pecific need for preventive maintenance. I n addition, the following procedur e can be used to keep Page/Party
®
systems o perat i n g effectively .
WARNING
Before performing any of the following preventive maintenance steps, remove
all power from the station.
1. Remove the a mplifier f rom the enclo sure.
2. Visually check the int erior of the enclosure for signs of c ontamination suc h as du st, c ondens ation or
process liquid.
3. Using the No. 10440-002 Maintenance Cable, plug the amplifier into the connector in the enclosur e.
Check, and if necessary, adju st the amplifier t o ma x i mize performa nc e.
4. Reinstall the amplif ier in the enclosure. Ensure t hat a ll gaskets and hardwar e are in place. F ailur e t o
install the gaskets, which als o act as s pacer s, can result in da ma ge to the connectors on t he amplifiers and insi de t he enclosur es and ca n c aus e s ystem faults .
It may become necessary to re-terminate some or all of the enclosures in a system. If so, strip the wires bac k to clean c opper and connect only one wire to eac h c onnector to allow for eas i er fut ure troubleshooting.
If the equip ment requires service, c ontact your Regional Service Center for a return authorization number (RA# ) . Equi p ment should be s hipped prepaid to GAI-Tronic s with the return au thoriz ation numb er and a purchas e order numb er. If the equipment is u nder war ranty, repairs will be made wit hout charge. Please include a written explanation of all defects to as sist ou r technic ians in t heir tr oubleshoot ing ef f orts . Call 800-492-1212 for help in identifying the Regional Service Center closest to you.
Troubleshooti ng
The following t able lists some hints to aid technicians in trou bleshooting.
Problem Solution
Feedback occurs only duri ng page.
Crosstalk occurs.
1. If a speaker is clos e t o the station, try u sing the muting f eature in the amplifier
enclosure at the termina l blocks. Connect the violet wire a t TB 1-8 t o TB1- 7 . Refer to the wiring diagram.
2. Ensu re tha t speakers att ached to other stat ions located nearby are not point ed in
your direction. If changing the or ient ation of the other s peakers has no ef f ect, mutual muting may be required. Mu tual muting silences all the sp eakers within proximity to t he affected s tations during a p age from any one of the mutually muted st ations . Connect the orange wire (s pare) to the TB1-7 of all the stations to be mutually mut e d . N
OTE: If too many stat ions are selected, paging coverage can
be adversely affected.
3. Check line ter mina tions a t the line balance assembly. Li ne b alance assembly
connections are critical.
One or mor e system cable pai rs may b e i mproper l y ter min ated . Visually in spec t th e system cable connections for acc idental cross i ng of the cab le p airs or grounds.
\\s_eng\gtc proddoc s \ s t andard iom s - current release\42004 inst r. m anuals \ 42004-623l2a. doc
10/03
Page 7
Pub. 42004-623L2A
Model 7335-004 Multi-Party Emergenc y P ar ty Line Amplifier Enclosure Page:
7 of 8
Specifications
Construction/finish:..................................Glass-reinforced polyester, J-hook latc h, hinged door wit h gasket
Mount ing: Wall, column or p ole (mounting kit r equired for pole mount), four 7/16 inch mounting holes
Connections:..............................................................................Internal screw-type barrier terminal blocks
Dimensions:...................................................... 14.6 H × 10.8 W × 10.5 D inches (371 × 274 × 267 mm)
Shipping weight:.......................................................................................................... 9.6 pounds (4.4 kg)
Approvals.....................NRTL Listed for USA and Canada................. Class I, Div. 2, Groups A, B, C, D;
Class II, Div. 2, Groups F and G; Class III, Div. 2
Out door environmenta l rating........................................................NEMA 3R, NEMA 4X with door closed
REPLACEMENT PARTS
Part Number Description
12251-001 Spring Door Kit 12504-004 Door Handle 12564-001 Party Line Knob and Label Kit 12505-005 Door and Hardware Kit 12535-003 Hardware Kit
\\s_eng\gtc proddoc s \ s t andard iom s - current release\42004 inst r. m anuals \ 42004-623l2a. doc
10/03
Page 8
Pub. 42004-623L2A
Model 7335-004 Multi-Party Emergenc y P ar ty Line Amplifier Enclosure Page:
8 of 8
\\s_eng\gtc proddoc s \ s t andard iom s - current release\42004 inst r. m anuals \ 42004-623l2a. doc
10/03
Page 9
Warranty
Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any
GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document. If (a) Seller’s goods prove to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above, Buyer may return such goods to GAI-Tronics’ nearest depot repair facility, freight prepaid, at which time they will be repaired or replaced, at Seller’s option, without charge to Buyer. Repair or replacement shall be Buyer’s sole and exclusive remedy. The warranty period on any repaired or replacement equipment shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original equipment was shipped. In no event shall GAI-Tronics warranty obligations with respect to equipment exceed 100% of the total cost of the equipment supplied hereunder. Buyer may also be entitled to the manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder. The applicability of any such third-party warranty will be determined by GAI-Tronics.
Services. Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,
shall be performed in accordance with the standard of care with which such services are normally provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided any and all issues are identified prior to the demobilization of the Contractor’s personnel from the work site. Re-performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAI­Tronics warranty obligations with respect to services exceed 100% of the total cost of the services provided hereunder.
Warranty Periods. Every claim by Buyer alleging a defect in the goods and/or services provided
hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty periods as set forth above. Provided, however, that if the defect complained of is latent and not discoverable within the above warranty periods, every claim arising on account of such latent defect shall be deemed waived unless it is made in writing within a reasonable time after such latent defect is or should have been discovered by Buyer.
Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not be
responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the equipment. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Return Policy
If the equipment requires service, contact your Regional Service Center for a return authorization number (RA#). Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a purchase order number. If the equipment is under warranty, repairs or a replacement will be made in accordance with the warranty policy set forth above. Please include a written explanation of all defects to assist our technicians in their troubleshooting efforts.
Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the Regional Service Center closest to you.
(Rev. 10/06)
Loading...