24 V DC Multi-Party Amplifier Enclosures

Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI­Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

General Information

This manual applies to the following GAI-Tronics amplifier enclosures:
Model Description
703-002 Indoor Amplifier Enclosure; multi-party, 24 V dc input
7325-102 Weatherproof Aluminum Enclosure; multi-party, 24 V dc input
7335-002 Weatherproof Non-metallic Amplifier Enclosure; multi-party, 24 V dc input
The amplifier enclosure is an important component of the 700 Series Page/Party® system. These enclosures are configured for multi-party systems and can accommodate conversations on up to five party lines simultaneously.
The Model 703-002 Indoor Amplifier Enclosure is constructed of fabricated steel. The Model 7325-102 Outdoor Enclosure is made of cast aluminum alloy, and the Model 7335-002 Outdoor Enclosure is made of glass-reinforced polyester. Both outdoor enclosures are extremely weatherproof and corrosion­resistant.
These enclosures are equipped with terminal strips for connecting inter-station cable. The 701 and 751 Series Amplifiers mate directly with these enclosures.

Installation

CAUTION
indicated on the approval listing in the “Specifications” section of this manual. Such installation may cause a safety hazard and consequent injury or property damage.
Do not install this equipment in hazardous areas or areas other than those
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V
Pub. 42004-141G Model 703-002, 7325-102, and 7335-002 Multi-Party 24 V DC Amplifier Enclosures Page 2 of 12
When installing an add-on station, consult the 24 V dc system layout diagrams at the end of this manual. These figures, when used in conjunction with the station installation information and cable layout guide, should provide all the information necessary to install additional Page/Party stations.
In 24-volt systems, plan on several branch lines from the dc source with no more than six stations per branch. One branch could span up to 4,000 feet for a single station. The Maximum Cable Distance Table lists the limits. Where two or more stations are listed, the assumption is that they are evenly spaced along the cable.
Each amplifier contains two fuses on the PCBA in the 24 V dc input to protect and isolate the handset and speaker amplifier circuitry in the event of a failure. Power line wiring to each amplifier or group of amplifiers should have a fuse or circuit breaker to protect against wiring failures.
If cable with No. 14 AWG power line conductors is used, a 15-amp fuse or circuit breaker should be installed for each branch line at the point it connects to the battery. Fuse or circuit breaker rating is determined by the size cable used in the branch. Consult the National Electrical Code (NFPA70) or Canadian Standards Association (CSA 22.1) for the maximum allowable capacity of the wire used.
The GAI-Tronics 24 V dc series of Page/Party
®
system equipment is designed to operate from a 24-volt
dc rechargeable battery. A battery charger may be connected to the battery to maintain the charge.
CAUTION
Under NO condition should this equipment be operated from a battery
charger without the batteries connected.
Most chargers have an unloaded output of 35 to 45 volts that can quickly damage the equipment designed for nominal 24 volts. To maintain a proper state of battery charge, the voltage across the batteries will be somewhat greater than 24 volts, but should never exceed 28.8 V dc. Grounding the negative side of the battery system at only one point is recommended and will ensure hum- and noise-free operation.

Enclosure Placement

All GAI-Tronics Page/Party® units are wired in parallel. Good system layout design minimizes the cable required for each installation. GAI-Tronics multi-conductor cable, designed especially for this application, is recommended. The number, size, and color-coding of conductors are listed in the accompanying system connection diagrams.
System layout and power cable length are important considerations when installing Page/Party equipment. Consult the Maximum Cable Distance table for typical cable lengths. The cable distance between stations as well as total cable distance must be considered. Cable distance is more strictly regulated in 24 V dc systems because of the amount of resistance these cables encounter—the longer the cable distance, the greater the resistance and IR losses (voltage drop) encountered.
®
f:\standard ioms - current release\42004 instr. manuals\42004-141g.doc
08/13
Pub. 42004-141G Model 703-002, 7325-102, and 7335-002 Multi-Party 24 V DC Amplifier Enclosures Page 3 of 12

Maximum Cable Distance in Feet*

Number of
Units
No. 14 AWG
Total / Between
No. 12 AWG
Total / Between
No. 10 AWG
Total / Between
No. 8 AWG
Total / Between
1 977 / 977 1,554 / 1,554 2,471 / 2,471 3,931 / 3,931
2 651 / 325 1,037 / 518 1,648 / 824 2,620 / 1,310
3 489 / 163 777 / 259 1,236 / 412 1,966 / 655
4 391 / 98 622 / 155 988 / 247 1,572 / 393
5 325 / 65 518 / 103 823 / 165 1,310 / 262
6 279 / 46 444 / 74 706 / 117 1,123 / 187
9 196 / 21 311 /34 494 / 55 786 / 87
*Based on the following assumptions:
Continuous tone (alarm) signals driving each station’s speaker amp to a maximum of 12 watts.
OTE: If the station is used for speech (audio) signals only, the distances stated above can be
N
multiplied by a factor of 2 because speech signals do not have the energy content that a continuous tone has; therefore, they do not require as much average current and thus less cable IR drop will result.
GAI-Tronics-supplied cable is used.
Wire resistance (ohms) is the nominal value for the applicable AWG at 1,000 feet of bare copper,
stranded wire @ 20º C (68º F). Wire resistance values used are as follows:
No. 14 AWG = ~2.525 ohms; No. 12 AWG = ~1.588 ohms; No. 10 AWG = ~0.999 ohm; No. 8 AWG = ~0.628 ohm
DC V at cable run’s feed point (Float charge of connected batteries) = ~26.6 V dc DC V at the last unit in cable run = 21 V dc minimum Station unit current draw (I) is the same regardless of the unit’s placement along the cable run for
ease of calculation. (1.1 amperes when unit is producing a 12-watt sine wave output.)
Distances reflect a 3% reduction for margin of error.
For conditions other than above, the following formula may be helpful in calculating the approximate maximum distance for a SINGLE station.
For CONTINUOUS tone applications
For SPEECH operation only
, multiply the above result by a factor of 2.
with minimum distortion:
Example: What is the approximate maximum distance for a single dc station if the voltage feed is 27.5
V dc and a No. 14 AWG wire is used @ 20º C?
Info:
No. 14 AWG @ 20º C = ~0.002525 ohm per foot 2 for LOOP R V
FEEDPOINT
= 27.5 V dc
Solution:
(27.5 V – 21 V) / ((2 0.002525 ohm per foot) 1.1 amps) = 6.5 / 0.005555
= 1,170 feet (for CONTINUOUS TONE
f:\standard ioms - current release\42004 instr. manuals\42004-141g.doc
08/13
signal), or up to ~2,340 feet (factor of 2) for SPEECH signals
Pub. 42004-141G Model 703-002, 7325-102, and 7335-002 Multi-Party 24 V DC Amplifier Enclosures Page 4 of 12

Mounting

The Model 7325-102 Weatherproof Metallic Enclosure is supplied with pre-drilled cable openings and conduit hubs with top and bottom cap plugs in place to prevent contamination. The Model 703-002 Indoor Enclosure and the Model 7335-002 Weatherproof Non-metallic Enclosure are not supplied with conduit or cable openings.
Drill or punch these openings using the template supplied before mounting the enclosure. The recommended cable entry point is via the bottom of the enclosure near the rear surface to prevent moisture from dripping onto the terminals or PCBAs. A secondary location for cable entry is in the top of the enclosure toward the sides. Avoid the top center, as it may interfere with the plug-in amplifier receptacle. Under no circumstances should cable entries be made in the side of the enclosure as this may interfere with the installation of the plug-in amplifier.
For specific details including mounting hole dimensions, refer to Figure 1 for the Model 703-002 Indoor Enclosure, Figure 2 for Model 7335-002 Weatherproof Non-metallic Enclosure, and Figure 3 for the Model 7325-102 Weatherproof Metallic Enclosure. When mounting the enclosure, use caution to avoid damaging the terminal blocks inside. The suggested mounting height for all station enclosures is 54 inches (137 cm) up to the centerline of the enclosure.
Figure 1. Model 703-002 Indoor Enclosure Mounting Details
f:\standard ioms - current release\42004 instr. manuals\42004-141g.doc