Pub. 42004-372B
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model 733-006 Single-Party Outdoor
Non-metallic Amplifier Enclosure
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAITronics retains all intellectual property and other rights in or to the information contained herein, and
such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
The Model 733-006 Single-Party Outdoor Non-metallic Amplifier Enclosure is a component of the 700
Series Page/Party< System. It is constructed of glass-reinforced polyester and is extremely weatherproof
and corrosion-resistant. This enclosure is equipped with terminal strips for connecting system cable.
The Page/Party
®
series amplifiers mate directly with this enclosure.
Installation
CAUTION
indicated on the approval listing in the “Specifications” section of this manual. Such installation
may cause a safety hazard and consequent injury or property damage.
WARNING
Do not disconnect equipment while energized.
Insure proper grounding to protective earthing.
When installing an add-on station, consult the appropriate system layout diagrams. These figures, when
used in conjunction with the station installation information and cable layout guide, should provide all
the information necessary to install additional Page/Party< stations.
Enclosure Placement
All GAI-Tronics Page/Party® units are wired in parallel. Good system layout design minimizes the cable
required for each installation. GAI-Tronics multi-conductor cable, designed especially for this
application, is recommended. For the number, size, and color-coding of conductors refer to the
appropriate system connection diagrams.
Do not install this equipment in hazardous areas or areas other than those
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V

Pub. 42004-372B
Model 733-006 Single-Party Outdoor Non-metallic Amplifier Enclosure Page:
2 of 7
System layout and power cable length are very important when installing Page/Party< equipment.
Although it varies for different systems, the general guideline is that the total power cable length should
not exceed 1 mile (5280 feet) for 120 V ac systems. The total cable length is the most important
consideration while cable length between the stations is generally not a factor.
Mounting
The Model 733-006 Enclosure is not supplied with conduit or cable openings. Drill or punch these
openings using the template supplied before mounting the enclosure. Whenever possible, do not enter an
enclosure from the top: side or bottom entry helps to prevent moisture from dripping onto the terminals
or PCBAs. The best location for conduit holes is along the bottom of the enclosure near the rear surface.
Avoid the top center, as it may interfere with the plug-in amplifier receptacle.
For specific details including mounting hole dimensions, refer to Figure 1. When mounting the
enclosure, use caution to avoid damaging the terminal blocks inside. The suggested mounting height for
all station enclosures is 54 inches (137 cm) up to the centerline of the enclosure.
The torque setting for securing the amplifier to the enclosure should be 10 to 12 in-lbs. or 1.13 to
1.36 n-m.
f:\standard ioms - current release\42004 instr. manuals\42004-372b.doc
11/10

Pub. 42004-372B
Model 733-006 Single-Party Outdoor Non-metallic Amplifier Enclosure Page:
3 of 7
Figure 1. Model 733-006 Enclosure Mounting Details
f:\standard ioms - current release\42004 instr. manuals\42004-372b.doc
11/10