Pub. 42004-161D
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model 670-001
Explosi on-proof Speaker Station
Confidentiality Notice
This manua l is provide d sole ly as an operatio nal, installation, and ma inte nance guide and conta ins
sensitive business and t e chnical informatio n tha t is confidentia l and pr opri et ary to GAI- Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manu al may not be dis clos e d in any form, in whole or in pa rt, direct ly or i ndir ectly, to a ny
third pa r ty.
General Information
The Model 670-001 Explosion-proof Speaker Station provides safe and clear communications in
hazardous areas, even in high-noise situations. This model is NRTL certified for use in the US and
Ca nada f or the f ollowing areas: Clas s I, Di v. 1, Group s C and D; Class II, Div. 1, Grou ps E, F, and G; and
Class III, Div. 1.
The Model 670-001 station enclosure is fabricated from cast aluminum and is suitable for indoor use. If
the station is to be mounted outdoors, it should be housed in a GAI-Tronics Model 10444-003
Weatherproof Non-metallic Encl osure. This e nclos ure is rated NEMA 4X, and can be purchased
separately.
This installation manual provides instructions on both the placement and mounting of the stations. Refer
to Pub. 42004-185 and 42004-237 (Canada), which show the conduit installation and station wiring
details necessary to maintain the explosion-proof integrity of the station.
WARNING
has been swi tched off or the area is known to be non-hazardo us.
Explos ion Hazard – Do not connect or dis connect equipment unless po w er
Installation
Whet her i nsta lling an entire syste m or only an add-o n sta tion, consu lt th e s yste m layou t dia grams at t he
end of this manual. These figures, used in conjunction with the station installation information and the
cable layout guide, should provide all the information necessary to install the Page/Party
figures do not show an explosion-proof station; however, the basic points of the system layout and design
stil l apply.
NOTE
a separate power feed, the Page/Party
disrupting the power supply to the other equipment in the Div. 1 area.
A separate power feed is recommended for Page/Party® stations in Div. 1 areas. With
®
stations c an be shut of f for service or ma inte nance wit hout
®
st ations. Th ese
GAI-Tronics Corporation P.O. Box 1060, Readi ng, PA 19607-1060 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V
Pub. 42004-161D
Model 670-001 Explosion-proof Speaker Station Page: 2 of 8
Enclos ure Placement
All GAI-Tronics Page/Par t y® units are wired in parallel. Good system layout design minimizes the cable
required for each installation. GAI-Tronics multi-conductor cable, designed especially for this
application, is recommended. The number, size, and color-coding of conductors are listed in the
accompanying system connection diagrams.
System layout and power cable length are important considerations when installing Page/Party
®
equipment. The rules vary for different systems, but generally, the total power cable length should not
exceed one mile (5280 feet) for 115 V ac systems. The length of cable between the stations is not a
factor; the total cable length is the most important consideration.
Mounting
Refer to Pub. 42004-185 and 42004-237 (Canada), shipped with this unit. The suggested mounting
height for all station enclosures is 54 inches (137 cm) up to the centerline of the enclosure.
To maintain the explosion-proof integrity of these stations, all mounting hardware is located outside the
enclosure. The unit should be mounted using the two mounting straps that extend past the four corners of
th e enclosure. See Figu re 1.
3
Use the standar d
bolts first, then the top bolts. The mounting strap design allows the station to be removed from its
mounting surface by removing only two of the bolts.
NOTE
10444-003 Weatherproof Non-metallic Enclosure, which is equipped with a front door. This enclosure
has four mounting feet in the four corners and is suitable for mounting to many surfaces. It can be
purchased separately.
/8-inch bolts to secure the enclosure to the mounting surface. Secure the bottom two
If this unit is to be used outdoors, it should be mounted inside a GAI-Tronics Model
\\s_eng\gtc proddoc s \st andard iom s - current release\42004 instr. manuals \ 42004-161d. doc
03/04
Pub. 42004-161D
Model 670-001 Explosion-proof Speaker Station Page: 3 of 8
Figure 1. Model 670-001 Mounting Details
\\s_eng\gtc proddoc s \st andard iom s - current release\42004 instr. manuals \ 42004-161d. doc
03/04