GAI-Tronics 400-004 User Manual

Pub. 42004-460B
GAI-TRONICS®
A HUBBELL COMPANY
Model 400-003 & 400-004 IEC/ATEX
Zone 1 RigCom Stations
This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.
General Information
GAI-Tronics Model 400-003 (120 V ac) and 400-004 (230 V ac) IEC/ATEX Zone 1 RigCom Stations are designed for common-talk, or master/slave communication system operation in IEC/ATEX Zone 1 hazardous locations.
The unit provides push-to-call, release-to-listen operation, and has a local on/off volume-control switch to activate and control the volume level for each station independently.
Models 400-003 and 400-004 have three M20 threaded entry holes for system, power, loudspeaker and optional remote microphone and footswitch connection.
The Models 400-003 and 400-004 are designed to operate with other 400 Series RigCom stations, and GAI-Tronics EZ Page Series of non-hazardous area rated equipment.
ure 1. Model 400-003/400-004 RigCom Station
Fig
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Pub. 42004-460B
Model 400-003 & 400-004 IEC/ATEX Zone 1 RigCom Stations Page 2 of 16
Important Safety Instructions
1. Read, follow, and retain instructions - All safety and operating instructions should be read and lowed before operating the unit. Retain instructions for future reference.
fol
2. Comply with all warnings on the unit and in the operating instructions.
3. Attachments not recommended by the product manufacturer shall not be used as they may
cause
hazards.
4. Do not attempt to service this unit yourself. Opening or removing covers may expose y
erous voltage or other hazards. Refer all servicing to qualified service personnel.
dang
ou to
5. Electrical and mechanical installation and connection should be in compliance with all regulations.
This permanently connected apparatus must have an ALL-POLE MAINS switch with a contac
ration of at least 3 mm in each pole incorporated in the electrical installation of the building.
sepa
t
Installation
These enclosures must be installed by trained, qualified and competent personnel. Installation must comply with state and national regulations, as well as safety practices for this type of equipment.
CAUTION
on the approval listing in the “Specifications” section of this manual. Such installation may cause a safety hazard and consequent injury or property damage.
Do not install this equipment in hazardous areas other than those indicated
The mounting location must be flat and provide proper clearance, rigidity and strength to support the enclosure and all contained devices.
Securely fasten the enclosure to the mounting location, using (customer-supplied) 11mm (7/16-inch) diameter steel mounting bolts and washers, or washer head bolts.
f:\standard ioms - cur rent release\42004 instr. manuals\42004-460b.doc 03/14
Pub. 42004-460B
Model 400-003 & 400-004 IEC/ATEX Zone 1 RigCom Stations Page 3 of 16
WARNING
Insure p
roper grounding to protective earthing.
Do not disconnect equipment while energized.
Inspect and clean the machined flange flame joint surfaces of both the cover and box. Surfaces must be smooth, free of nicks, scratches, dirt or any foreign particle build-up that would prevent a proper seal. Surfaces must seat fully against each other to provide a proper explosion-proof joint. Clean surfaces by wiping with a clean lint-free cloth.
Make certain no cover bolts are omitted. Use only those bolts supplied with the enclosure. Recommended torque setting of cover bolts: 23 N-m (17 ft-lbs).
Mounting
NOTE: The mounting surface must be able to support the weight of the aluminum enclosure. The unit weight is 10.5 kg (23.0 lbs).
The enclosure must be securely fastened with 11mm (7/16-inch) diameter steel mounting bolts located on all four mounting feet. Stainless steel hardware is recommended for applications in corrosive environments. Refer to Figure 2 for mounting dimensions.
ure 2. Model 400-003/400-004 Mounting Details and Entries
Fig
f:\standard ioms - cur rent release\42004 instr. manuals\42004-460b.doc 03/14
Pub. 42004-460B
Model 400-003 & 400-004 IEC/ATEX Zone 1 RigCom Stations Page 4 of 16
Hardware Configuration
External
The enclosure contains a push-to-call push button, an on-off/volume-control switch and applicable approval labeling. There are twelve 5/16-18 1.25-inch cover mounting bolts located around the perimeter of the enclosure.
The enclosure has an external grounding screw located on the underside of the flange. See Figure 2.
GAI-TRONICS CORPORATION
400 E. Wyomissing Ave., Mohnton, PA 195 40 USA
SERVICE CENTERS: In USA: 1-800-492-1212 Outside USA: 1-610-777-1374
OFF-ON VOLUME
PUSH TO CALL
Figure 3. Model 400-003/400-004 RigCom Station Outline
Internal
The enclosure contains a single PCBA to which all customer cable terminations are made. Internal connections to the front cover assembly are by a plug-in single wiring harness with a plug. Internal grounding terminals are provided for ground connection.
f:\standard ioms - current release\ 42004 instr. manuals\42004-460b.doc 03/14
Pub. 42004-460B
Model 400-003 & 400-004 IEC/ATEX Zone 1 RigCom Stations Page 5 of 16
Wir ing
Station Wiring
While supporting the front cover, remove the 12 cover bolts on the enclosure flange. Pull the front cover far enough away to expose the internal connections and disconnect any wiring between the front cover and rear enclosure. Place the front cover aside.
Attach the cable glands to the holes on the bottom of the enclosure.
Cable glands must be certified to current ATEX and IECEx standards for type ‘d’ Flameproof protection as well as ambient protection.
In rigid conduit systems, a sealing fitting must be installed in accordance with local codes.
Feed the low-voltage wiring in the left side hole and the power wiring through the right side hole. Refer to Figure 2.
Attach the wires to the terminal blocks located on the PCBA within the enclosure. See Figure 4 and charts for connection points and descriptions. Use one conductor (0.50 mm
2
to 4 mm2) per screw
terminal. Apply torque to 0.6 N-m.
If using the 10438-101 Auxiliary Microphone Assembly, connect the assembly to the station at terminal block TB4-1 (+) and TB4-2 (), shield to TB4-5, if used. The maximum distance from the station is 50 feet using 1 mm
2
wire.
If using an auxiliary footswitch assembly (customer-supplied), connect the assembly to the station at terminal block TB4-8 (+) and TB4-9 (), shield to TB4-5, if used. The maximum distance from the station is 50 feet using 1 mm
2
wire.
In this operation, the auxiliary microphone replaces the speaker as the microphone, and the auxiliary footswitch provides parallel functionality to the push-to-call switch.
f:\standard ioms - current release\ 42004 instr. manuals\42004-460b.doc 03/14
Pub. 42004-460B
Model 400-003 & 400-004 IEC/ATEX Zone 1 RigCom Stations Page 6 of 16
Figure 4. RigCom Station PCBA - Model 400-003 PCBA shown
(with Model 400-004 difference shown in pull out)
f:\standard ioms - current release\ 42004 instr. manuals\42004-460b.doc 03/14