General Information
The Model 230-001 Pole Mounting Kit is for use with all GAI-Tronics LEXAN® and polyes ter
weatherpr oof enc losur es . Instructions f or mounting the br acket to a pole are lis ted below. After t he
bracket is mounted, r ef er to the ins tallation ins tru c tions for your type of enclosure: either LEX AN
polyester.
®
or
Brack et Mounting Procedure
1. The brac ket should be mount ed 5 4 inches from the floor to the centerline of the brac ket .
2. For poles up to 5 inches in diameter, the 1/2-13 × 1-1/2 inch hex head machine screws should be used.
The pole should be drilled a nd tap ped for 1/2-1 3 bolts . See Figure 1.
3. For poles over 5 inches in diameter, and up to 15 inches in diameter, universal clamps should be used.
See Figu re 1.
Figure 1. B rac ket Mounting Dia gram
GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA
610-777-1374 800-492-1212 Fax : 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V
Pub. 42004-091A
Model 230-001 Pole Mounting Kit Page:
To Install: With the screw fully retracted, wrap the band around the
pole. Insert the free end of t he b and through the bottom slot in the
bracket. See Figure 2.
To Tighten: Pull the band tight ar ound the pole, and maintain the
tension while pulling the ba nd back away from the screw. Tighten
the thumbscrew. For extra clamping pressure, use pliers or a wrench.
See Figu re 3.
To Remove: Loosen the thumbscrew to the fully retracted position.
Pr es s down on the thumbscrew, a nd feed the loose end of the s trap
bac k through the slot. S ee F i gure 4.
Lexan® Enclosure Mounting
Use the hex head 5/16-18 × 1-inch ma c hine s c rews, lock washers,
and flat washers, to bolt the enclosure onto the bracket a s shown in
Figure 5.
Polyester Enc losure Mounting
2 of 2
1. Open the door to ga in access to t he equipment.
2. Loosen the four ou ter sc rews, pull back the mid-section, dis c onnect any cables, and p ull the unit away
fr o m the r ear enclosure.
3. Mount the rear enclosure to the b racket using t he Phillips hea d ¼-20 × 1-inch machine s c rews and loc k
washers. See F i g ure 6.
4. Replace the mid-section by reconnec ting the ca bles, pushing the mid-section int o place, and t i ghtening
the four outer screws.
\\s_eng\gtc proddoc s \ s t andard iom s - current release\42004 inst r. m anuals \ 42004-091a. doc