Gai Tronics 17688 User Manual

Pub. 42004-538AQG
G A I - T R O N I C S®
A H U B B E L L C O M P A N Y
HUBBCOM GRC600 Remote Station
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
General Information
This guide covers the installation of the HUBBCOM Remote Station, Model GRC600. The Model GRC600 Remote Station is designed for access control See the GAI-Tronics website at https://www.gai-tronics.com for system specifications, warranty information, and the GUDA (GAI-Tronics Universal Device Application).
Important Safety Instructions
Read, follow, and retain instructions—All safety and operating instructions should be read and followed
before operating the unit. Retain instructions for future reference.
Heed warningsAdhere to all warnings on the unit and in the operating instructions.
AttachmentsAttachments not recommended by the product manufacturer should not be used, as they may
cause hazards.
Servicing—Do not attempt to service this unit by yourself. Opening or removing covers may expose you to
dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
Changes or Modifications Not Expressly Approved By GAI-Tronics For Compliance Could Void The
User's Authority To Operate The Equipment.
ATTENTION
Install equipment without modification and according to all applicable local, national, and international electrical codes. North America - Consult the National Electrical Code (NFPA 70), Canadian Standards Association (CSA 22.1), and local codes for specific requirements regarding your installation. Class 2 circuit wiring must be performed in accordance with the NEC.
These enclosures must be installed by trained, qualified and competent personnel. Installation must comply with state and national regulations, as well as safety practices for this type of equipment.
WARNING
Use only 24 V dc power supplies that conform to UL/CSA/CE Class II, Double Insulated
supplies with over voltage and short circuit protection. Use only a dc source with a 50­watt maximum output or fuse the supply with a 2-amp fuse. EMI standards to Class B.
OnderhoudProbeer dit apparaat niet zelf te repareren. Het openen of verwijderen van afdekkingen kan u
blootstellen aan gevaarlijke spanning of andere gevaren. Laat alle onderhoud over aan bevoegd onderhoudspersoneel.
HUBBCOM Smart Controllers zijn alleen bedoeld voor gebruik binnenshuis.
AANDACHT
Gebruik alleen 24 VDC-voedingen die voldoen aan UL / CSA / CE Klasse II, dubbel
geïsoleerde voedingen met overspanning en kortsluitbeveiliging. Gebruik alleen een DC-bron met een maximale output van 50 W of fuseer de voeding met een 2-ampère zekering. EMI-normen voor klasse B.
DépannageN'essayez pas de réparer cet appareil vous-même. Ouvrir ou retirer les capots peut vous exposer à
des tensions dangereuses ou à d'autres dangers. Confiez toute réparation à un personnel qualifié.
Les contrôleurs intelligents HUBBCOM sont conçus pour une utilisation en intérieur uniquement.
Pub. 42004-538AQG
HUBBCOM GRC600 Remote Station Quick Installation Guide Page 2 of 5
C:\Users\PDrenning\AppData\Local\Microsoft\Windows\INetCache\Content.Outlook\PB6OVX22\HUBBCOM GRC600 Remote Station Quick Installation Guide.docx
10/19
ATTENTION
Utilisez uniquement des alimentations 24 Vcc conformes à UL / CSA / CE Classe II, des
alimentations à double isolation avec protection contre les surtensions et les courts­circuits. Utilisez uniquement une source cc avec une sortie maximale de 50 watts ou fusionnez l’alimentation avec un fusible de 2 ampères. Normes EMI à la classe B.
Manutenzionenon tentare di riparare l'unità da soli. L'apertura o la rimozione dei coperchi potrebbero esporre
a tensioni pericolose o altri rischi. Rivolgersi a personale qualificato per l'assistenza.
Gli HUBBCOM Smart Controller sono progettati esclusivamente per uso interno.
AVVERTIMENTO
Utilizzare solo alimentatori a 24 V cc conformi a UL / CSA / CE Classe II,
alimentatori a doppio isolamento con protezione da sovratensione e cortocircuito. Utilizzare solo una fonte di corrente continua con un'uscita massima di 50 watt o collegare l'alimentazione con un fusibile da 2 A. Standard EMI per la classe B.
Mantenimientono intente reparar esta unidad por sí mismo. Abrir o quitar las cubiertas puede exponerlo a un
voltaje peligroso u otros peligros. Remita todo el servicio a personal de servicio calificado.
Los controladores inteligentes HUBBCOM están diseñados para uso en interiores solamente.
ADVERTENCIA
Utilice solo fuentes de alimentación de 24 V cc que cumplan con UL / CSA / CE
Clase II, fuentes con doble aislamiento con sobretensión y protección contra cortocircuitos. Utilice solo una fuente de CC con una salida máxima de 50 vatios o fusione la fuente con un fusible de 2 amperios. Estándares EMI a Clase B.
Installation
The HUBBCOM Remote Station can be surface mounted on a wall or flush mounted using a (customer provided) two-gang electrical box.
Safety Hardware
The HUBBCOM Remote Station described in this manual is vandal resistant. The front cover is attached to the mounting plate with security screws. A Torx T-10 security screwdriver is required to install the station.
Surface-mount
1. Remove the two security screws from the bottom of the station.
2. Drill two holes through the mounting plate at the drill points and corresponding holes in the mounting surface.
3. Secure the mounting plate to the wall using ? (customer supplied).
4. Feed the Ethernet cable and all additional cables through the hole in the mounting plate.
5. Complete all necessary cable terminations (see the Wiring section).
6. Assemble the front cover to the mounting plate and secure it with the two security screws removed from the
bottom of the station in Step 1.
7. Tighten the screws to 3–5 inlb.
Flush-mount
NOTE: A customer supplied two-gang electrical box is required to flush-mount the HUBBCOM Remote Station.
1. Install the two-gang electrical box in the mounting surface.
2. Remove the two security screws from the bottom of the station.
3. Feed the Ethernet cable and all additional cables into the electrical box and through mounting plate.
4. Assemble the mounting plate to the electrical box using #6-32 x ½-inch flat head screws (customer supplied).
5. Complete all necessary cable terminations (see the Wiring section).