
Pub. 42003-258C
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Hazardous Area ICS SmartSeries PCBA
Upgrade Kit
Model 12826-001
Confidential ity Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
The Model 12826-001 Hazardous Area ICS SmartSeries PCBA Upgrade Kit adds microprocessor control
to the ICS Page/Party
with or without ADVANCE head-end equipment.
The Hazardous Area ICS SmartSeries PCBA Upgrade Kit provides the following components:
Qty Description
1 ICS SmartSeries Module PCBA
1 Ribbon Cable Assembly
3 F/F Nylon standoffs, 1.25-inches long
1 M/F Standoff, 1.25-inches long
6
1
1 Label, Upgrade Kit
®
station, providing additional sensor and monitoring capabilities. It can be used
Screw, 4 5/16-inch PHTF
Screw, 4-40 ¼-inch PHMS
Installation
WARNING
power from the station.
Before performing any of the following settings and adjustments, remove all
WARNING
from the supply circuit before making any adjustments to the amplifier’s handset level.
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
To reduce the risk of hazardous atmospheres, disconnect the equipment
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS

Pub. 42003-258C
ODEL 12826-001 HAZARDOUS AREA ICS SMARTSERIES PCBA UPGRADE KIT Page 2 of 4
M
Opening the Station
Remove all cover bolts from the enclosure. Swing the front door open to access the internal PCBAs. See
Figure 1.
Figure 1. ICS Hazardous Area Station – Interior View
Installing the SmartSeries PCBA
1. Unplug the ribbon cable on the Main PCBA at P3.
2. Remove the four screws that secure the Main PCBA to the front cover.
3. Remove the six jumpers on the Main PCBA P4 connector and discard them.
4. Carefully flip over the Main PCBA and attach three nylon standoffs to the board using three 4 5/16
PHTF screws shown in Figure 2. Do not mount the SmartSeries PCBA to the Main PCBA at this
time.
5. Install the provided 34-pin ribbon cable from P4 of the Main PCBA to P4 of the SmartSeries PCBA.
6. Reattach the Main PCBA to the front cover using three of the four screws removed. Use the M/F
standoff in the fourth hole to secure the Main PCBA. See Figure 2.
7. Flip the SmartSeries PCBA over, so that the components are facing down. Secure the SmartSeries
PCBA to the Main PCBA using three of the PHTF screws (provided) for the F/F nylon standoffs and
the 4-40 screw for the one M/F standoff.
f:\standard ioms - current release\42003 kit manuals \42003-258c.doc
01/14